User Manual
Chapter 2
GFK-1742F
Jan 2020
System Overview
20
2.2.3
Connecting the
Series SVU Digital Servo Amplifier
Skip to the next section if you are connecting a
β
Series amplifier.
The
Series Digital Servo Amplifier does not require tuning adjustment during initial startup
or when a component is replaced. It also does not need adjustment when environmental
conditions change.
To connect the
Series Digital Servo Amplifier, follow the steps outlined below.
1.
Connect the
Series Servo Amplifier to the DSM314.
A.
Before connecting the servo command cable, make sure the DSM314 faceplate
shield ground wire is connected. This wire is shipped with the DSM314 module
and must be connected from the ¼ inch blade terminal on the bottom of the
module to a suitable panel earth ground.
B.
The servo command cable contains the pulse width modulated (PWM) output
signal from the DSM, the serial data from the motor encoder, and diagnostic
signals from the amplifier. The signals carried in this cable are at data
communications voltage levels and should be routed away from other
conductors, especially high current conductors.
C.
Locate the servo command cable IC800CBL001 (1 meter) or IC800CBL002 (3
meter). Insert the mating end of this cable into the connector JS1B, located on
the Servo Amplifier bottom (see Figure 2-4).
D.
If you are not using the IC693ACC335 axis terminal board to break out user I/O
such as overtravel or home limit inputs, insert the other end of the cable into the
connector labeled A, for axis 1, or B for axis 2, on the front of the DSM314. If you
are using the terminal board, insert the other end of the cable into the terminal
block connector marked SERVO. Next locate the terminal board connection
cable IC693CBL324 (1 meter) or IC693CBL325 (3 meter). Insert one end of this
cable into the terminal board connector marked DSM. Insert the other end of the
cable into the connector labeled A, for servo axis 1, or B for servo axis 2, on the
front of the DSM314 module.
Note:
Refer to “I/O Connections” in chapte
r 3 for information concerning the user I/O available for
IC693ACC335 terminal block connections.