Emerson Dixell XRi77CX Скачать руководство пользователя страница 3

 

1592020670 XRi77CX-CH GB r1.1 15.10.2019

 

XRi77CX-CH

 

3/9

 

10.

 

FRONT PANEL AND COMMANDS 

 

 

 

 

 

To display target set point; in programming mode it selects a parameter or 

confirm an operation. 

 

(

DEF

) To start a manual defrost. 

 

(

UP

) To see the used parameter map. When in programming mode, it browses 

the parameter codes or increases the displayed value. 

 

(

DOWN

) To see the used parameter map. When in programming mode, it 

browses the parameter codes or decreases the displayed value. 

Keep it pressed 5 sec to change parameter map from “nt” to “Lt” and vice

-versa 

(valid when button properly configured). 

 

To switch the instrument on and off (when 

onF=oFF

).  

 

To switch on and off the light (when 

oAx=LiG

). 

 

KEY COMBINATIONS: 
 

 

+

 

 

To lock & unlock the keyboard 

 +

 

 

To enter in programming mode 

 +

 

 

To exit the programming mode 

10.1

 

USE OF LEDS 

Icon functions are described in the following table: 
 

LED 

MODE  FUNCTION 

 

ON 

Compressor enabled 

Flashing  Anti-short cycle delay enabled 

 

ON 

Defrost enabled 

Flashing  Drip time in progress 

 

ON 

Fans enabled 

Flashing  Fans delay after defrost in progress. 

 

ON 

An alarm is occurring 

 

ON 

A PULL DOWN is running 

 

 

ON 

Energy saving enabled 

 

ON 

Light on 

 

ON 

Auxiliary relay on 

,

 

ON 

Measurement unit 

Flashing  Programming phase 

11.

 

MAX & MIN TEMPERATURE MEMORIZATION 

11.1

 

HOW TO SEE THE MIN TEMPERATURE 

1.

 

Press and release the 

DOWN 

button (if properly configurated). 

2.

 

The “

Lo

” message will be displayed followed by the minimum temperature recorded.

 

3.

 

By pressing the 

DOWN

 button again or waiting for 5 sec the normal display will be restored. 

11.2

 

HOW TO SEE THE MAX TEMPERATURE 

1.

 

Press and release the 

UP 

button (if properly configurated). 

2.

 

The “

Hi

” message will be displayed followed by the maximum temperature recorded.

 

3.

 

By pressing the 

UP 

button again or waiting for 5 sec the normal display will be restored. 

11.3

 

HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED 

1.

 

Keep 

SET 

button pressed for more than 3 sec while the max or min temperature is displayed. 

(

rSt

 message will be displayed) 

2.

 

After  confirming  the  operation, 

the  “

rSt

”  message 

will  start  blinking  and  then  the  normal 

temperature will be displayed. 

12.

 

MAIN FUNCTIONS 

12.1

 

TO SET THE CURRENT TIME AND DAY (ONLY WITH RTC) 

When the instrument is switched on, it could be required to set the real-time clock. 
1.

 

Enter the Pr1 programming menu by keeping both 

SET+DOWN

 buttons pressed for 3 sec. 

2.

 

Browse to the 

rtC

 menu and then push the 

SET

 key to enter the real time clock menu. 

3.

 

The 

Hur

 (hour) parameter is displayed. 

4.

 

Push the 

SET

 and set current hour by the 

UP

 and 

DOWN

 keys, then push 

SET

 to confirm the 

value. 

5.

 

Repeat  the  same  operations  with 

Min

  (minutes)  and 

dAy

  (day)  parameters  and  other 

parameters. 

 

To exit: 

Push both 

SET+UP

 buttons or wait for 15 sec without pushing any button. 

12.2

 

HOW TO SEE THE SET POINT 

1.

 

Push and immediately release the 

SET 

key: the display will show the Set point value 

2.

 

Push and immediately release the 

SET 

key or wait for 5 sec to display the probe value again 

12.3

 

HOW TO CHANGE THE SET POINT 

1.

 

Push the 

SET 

button for 3 sec to change the Set point value. 

2.

 

The value of the set point will be displayed and the 

°C 

or

 °F 

icon will start blinking 

3.

 

Use the 

UP 

or 

DOWN 

buttons to modify the current value 

4.

 

Use the 

SET

 button to store the new value into memory 

12.4

 

HOW TO START A MANUAL DEFROST 

Keep the 

DEF 

button pressed for 3 sec to start a manual defrost. 

12.5

 

HOW TO ENTER PARAMETER PROGRAMMING MENU 

“PR1”

 

Follow these steps:  
1.

 

Enter the Programming mode by pressing the 

SET+DOWN 

buttons for 3 sec (the 

°C 

or

 °F

 LED 

will start blinking) 

2.

 

Browse to the required parameter and then press the 

SET

 button to display its current value 

3.

 

Use 

UP

 or 

DOWN 

buttons to change its value 

4.

 

Press 

SET 

button to store the new value and move to the following parameter 

 

To exit

: press 

SET+UP 

buttons or wait for 15 sec without pressing any key. 

 
NOTE

: the set value is stored even when the procedure exits by waiting for the time-out 

12.6

 

HOW TO ENTER PARAMETER 

PROGRAMMING MENU “PR2”

 

The manufacturer menu (Pr2) includes all the parameters of the instrument. 

12.6.1

 

ENTERING THE PARAMETER PROGRAMMING MENU “PR2”

 

1.

 

Enter the Programming mode by pressing the 

SET+DOWN 

buttons for 3 sec (the 

°C 

or

 °F

 icon 

will start blinking). 

2.

 

Released the buttons and then push again the 

SET+DOWN 

buttons for more than 7 sec. The 

Pr2 label will be displayed immediately followed from the 

HY

 parameter. 

 

NOW THE PARAMETER MENU “PR2” IS 

AVAILABLE FOR ANY MODIFICATION 

 
3.

 

Browse to the required parameter. 

4.

 

Press the 

SET

 button to display its value. 

5.

 

Use 

UP 

or 

DOWN 

to change its value. 

6.

 

Press 

SET

 to store the new value and move to the following parameter. 

 

To exit:

 press 

SET+DOWN 

or wait for 15 sec without pressing any key. 

 
NOTE1: 

if no parameter is present in Pr1 menu, after 3 sec 

the “

noP

” message 

will be displayed. Keep 

the buttons pushed till the Pr2 message will be displayed.  
 

NOTE2:

 the set value is stored even when the procedure ends by waiting for the time-out 

12.6.2

 

HOW  TO  MOVE  A  PARAMETER  FROM  “PR2”  MENU  TO  “PR1”  MENU  AND  VICE

-

VERSA 

Each parameter present in the hidden menu (Pr2) can be moved into the user level (Pr1) by pressing 
both 

SET+DOWN 

buttons. If a parameter is part of the user level, when showed in the hidden menu 

the decimal point will be lit. 

12.7

 

HOW TO LOCK THE KEYBOARD 

1.

 

Keep both 

UP

 and 

DOWN

 buttons pressed more than 3 sec. 

2.

 

The “

PoF

” message will be displayed, and the keyboard will be locked. At this point it will be 

possible only to see the set point or the MAX o Min temperature stored 

3.

 

If a button is pressed more than 3 sec 

the “

PoF

” message will be displayed.

 

12.8

 

HOW TO: UNLOCK THE KEYBOARD 

Keep both 

UP 

and 

DOWN

 pressed more than 3 sec till the 

“Pon” 

message will be displayed. 

12.9

 

THE ON/OFF FUNCTION 

 

By pushing the 

ON/OFF

 key, the instrument will go in stand-by. 

During the stand-by status, all the relays are switched OFF and the regulations are stopped; 
if a monitoring system is connected, it does not record the instrument data and alarms. 

 

WARNING: Loads connected to the normally closed contacts of the relays are always supplied 
and under voltage, even if the instrument is in stand-by mode.  

13.

 

PARAMETERS 

rtC 

Real time clock menu (only for controller with RTC):

 to set the time and date and 

defrost start time. 

REGULATION 

LS   

Minimum set point:

 (-100°C to SET; -148°F to SET) sets the minimum value for the 

set point. 

US 

Maximum set point:

 (SET to 150°C; SET to 302°F) set the maximum value for set 

point. 

HY 

Differential for normal regulation (compressor cut-in):

 (0.1 to 25.5°C; 1 to 45°F) 

differential for set point. Compressor Cut IN is Set Point + differential (HY). Compressor 
Cut OUT is when the temperature reaches the set point. 

odS 

Outputs delay activation after power on:

 (0 to 255min) this function is enabled at 

the initial start-up of the instrument and inhibits any output activation for the period set 
in the parameter.  

AC   

Compressor  anti-short-cycle  delay:

  (0  to  50min)  minimum  interval  between  the 

compressor stop and the following restart. 

AC1    Second compressor anti-short-cycle delay:

 (0 to 50min) minimum interval between 

the second compressor stop and the following restart. 

Содержание Dixell XRi77CX

Страница 1: ...t RTC EdF rtC the defrost is real time controlled depending on the hours set in the parameters Ld1 Ld6 for workdays Other parameters are used to control defrosting cycles the maximum length MdF and defrosting modes timed or controlled by the evaporator s probe P2P At the end of defrost dripping time is started its length is set in the Fdt parameter With Fdt 0 the dripping time is disabled 3 2 1 PR...

Страница 2: ... to set the regulation HY1 Differential for proportional regulation 0 1 to 25 5 C 1 to 45 F Fr0 Frequency output value with compressor stopped 0 to 50Hz frequency output signal when compressor stopped PMi Minimum compressor speed in percentage 0 to PMA PMA Maximum compressor speed in percentage PMi to 100 voS Signal output variation increment when temperature is increasing if vdC FrE then 1 to 100...

Страница 3: ...g mode by pressing the SET DOWN buttons for 3 sec the C or F LED will start blinking 2 Browse to the required parameter and then press the SET button to display its current value 3 Use UP or DOWN buttons to change its value 4 Press SET button to store the new value and move to the following parameter To exit press SET UP buttons or wait for 15 sec without pressing any key NOTE the set value is sto...

Страница 4: ... idF is expired tdF Defrost type EL in EL electrical heater in hot gas dFP Probe selection for defrost control nP P1 P2 P3 P4 nP no probe P1 thermostat probe P2 evaporator probe P3 configurable probe P4 Probe on Hot Key plug dtE Defrost end temperature 55 to 50 C 67 to 122 F enabled only when EdF Pb sets the temperature measured by the evaporator probe which causes the end of defrost idF Interval ...

Страница 5: ... condition and its signalling When i1F PAL it is the interval of time to calculate the number of pressure switch activation d2d Digital input 2 alarm delay 0 to 255 min delay between the detection of the external alarm condition and its signalling When i1F PAL it is the interval of time to calculate the number of pressure switch activation nPS Number of pressure alarm events before stopping the re...

Страница 6: ... and then turn the Controller ON 3 The parameter list of the HOT KEY will be automatically downloaded into the Controller memory The doL message will blink followed a by a flashing End label 4 After 10 seconds the instrument will restart working with the new parameters 5 Remove the HOT KEY NOTE the message Err is displayed for failed programming In this case turn the unit off and then on if you wa...

Страница 7: ...ion for defrost control P2 Pr2 dtE Defrost termination temperature 4 0 Pr2 idF Interval between two consecutives defrost cycles 24 Pr2 MdF Maximum length for defrost 45 Pr2 dSd Start defrost delay 0 Pr2 StC Compressor stop time before starting any defrost 5 Pr2 dFd Displaying during defrost it Pr1 dAd Delay for display temperature update after any defrost 20 Pr1 Fdt Draining time 5 Pr2 Hon Drain h...

Страница 8: ...in percentage 100 Pr2 voS_nt Compressor speed variation increment when temperature is increasing 1 Pr2 vo2_nt Compressor speed variation decrement when temperature is decreasing 2 Pr2 vo3_nt Compressor speed variation decrement after any Pull Down 5 Pr2 PdP_nt Compressor speed during any Pull Down 100 Pr2 t1F_nt Time with compressor speed at PMI before stopping the compressor 1 Pr2 SPi_nt Compress...

Страница 9: ...arity CL Pr2 i2F_nt Digital input 2 configuration EAL Pr2 did_nt Digital inputs 1 alarm delay 1 Pr1 d2d_nt Digital inputs 2 alarm delay 1 Pr2 nPS_nt Number of pressure alarm switch before stopping the regulation Lock alarm 15 Pr1 OdC_nt Compressor and fan status after door opening F C Pr1 rrd_nt Regulation restart after open door alarm yes Pr1 HES_nt Differential for energy saving mode 0 Pr1 LdE_n...