background image

 

1592020040 XR40CX GB m&M r1.1 22.06.2012 

XR40CX 

1/4 

Digital controller with defrost management

 

XR40CX 

 

CONTENTS 
1.

 

GENERAL WARNING__________________________________________________________1

 

2.

 

GENERAL DESCRIPTION ______________________________________________________1

 

3.

 

CONTROLLING LOADS________________________________________________________1

 

4.

 

FRONT PANEL COMMANDS ___________________________________________________1

 

5.

 

MAX & MIN TEMPERATURE MEMORIZATION _____________________________________1

 

6.

 

MAIN FUNCTIONS ____________________________________________________________1

 

7.

 

PARAMETERS _______________________________________________________________2

 

8.

 

DIGITAL INPUT (ENABLED WITH P3P = N)________________________________________3

 

9.

 

TTL SERIAL LINE – FOR MONITORING SYSTEMS _________________________________3

 

10.

 

X-REP OUTPUT – OPTIONAL___________________________________________________3

 

11.

 

INSTALLATION AND MOUNTING ________________________________________________3

 

12.

 

ELECTRICAL CONNECTIONS __________________________________________________3

 

13.

 

HOW TO USE THE HOT KEY ___________________________________________________3

 

14.

 

ALARM SIGNALS _____________________________________________________________3

 

15.

 

TECHNICAL DATA ____________________________________________________________3

 

16.

 

CONNECTIONS ______________________________________________________________3

 

17.

 

DEFAULT SETTING VALUES ___________________________________________________4

 

1.

 

GENERAL WARNING 

1.1

 

PLEASE READ BEFORE USING THIS MANUAL 

 

This  manual  is  part of the product and should be kept near the instrument for easy and quick 
reference. 

 

The  instrument  shall  not  be  used  for  purposes  different  from  those  described  hereunder.  It 
cannot be used as a safety device. 

 

Check the application limits before proceeding. 

 

Dixell  Srl  reserves  the  right  to  change  the  composition  of  its  products,  even  without  notice, 
ensuring the same and unchanged functionality. 

1.2

 

 SAFETY PRECAUTIONS 

 

Check the supply voltage is correct before connecting the instrument. 

 

Do  not expose to water or moisture: use the controller only within the operating limits avoiding 
sudden  temperature  changes  with  high  atmospheric  humidity  to  prevent    formation  of 
condensation 

 

Warning: disconnect all electrical connections before any kind of maintenance. 

 

Fit the probe where it is not accessible by the End User. The instrument must not be opened. 

 

In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” 
(see address) with a detailed description of the fault. 

 

Consider the maximum current which can be applied to each relay (see Technical Data). 

 

Ensure  that  the  wires  for  probes,  loads  and  the  power  supply  are  separated  and  far  enough 
from each other, without crossing or intertwining. 

 

In  case  of  applications  in  industrial  environments,  the  use  of  mains  filters  (our  mod.  FT1)  in 
parallel with inductive loads could be useful. 

2.

 

GENERAL DESCRIPTION 

Model XR40CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on 
medium  or  low  temperature  refrigerating  units.  It  has  2  relay  outputs  to  control  compressor  and 
defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with three NTC or 
PTC  probe  inputs,  the  first  one  for  temperature  control,  the  second  one,  to  be  located  onto  the 
evaporator,  to  control  the  defrost  termination  temperature,  the third one, optional, to connect to the 
HOT  KEY  terminals  to  signal  the  condenser  temperature  alarm  or  to  display  a  temperature.  The 
digital input can operate as fourth temperature probe. 
The  HOT  KEY  output allows to connect the unit, by means of the external module XJ485-CX,  to a 
network  line  ModBUS-RTU  compatible  such  as  the 

dIXEL 

monitoring  units    of  X-WEB  family.  It 

allows to program the controller by means the HOT KEY programming  keyboard.  
The  instrument  is  fully  configurable  through  special  parameters  that  can  be  easily  programmed 
through the keyboard. 

3.

 

CONTROLLING LOADS 

3.1

 

COMPRESSOR 

The regulation is performed according to 
the  temperature  measured  by  the 
thermostat  probe  with  a  positive 
differential  from  the  set  point:  if  the 
temperature  increases  and  reaches  set 
point  plus  differential  the  compressor  is 
started  and  then  turned  off  when  the 
temperature  reaches  the set point value 
again. 

Time

Temper.

Compr.

SET

ON

 

In  case  of  fault  in  the  thermostat  probe  the  start  and  stop  of  the  compressor  are  timed  through 
parameters “COn” and “COF”. 

3.2

 

DEFROST 

Two defrost modes are available through the “tdF” parameter: defrost through electrical heater (tdF = 
EL
)  and  hot  gas    defrost  (tdF  =  in).  Other  parameters  are  used  to  control  the  interval  between 
defrost  cycles  (IdF),  its  maximum  length  (MdF)  and  two  defrost  modes:  timed  or  controlled  by  the 
evaporator’s probe (P2P).  
At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the 
dripping time is disabled. 

4.

 

FRONT PANEL COMMANDS 

 

 

:  To  display  target  set  point;  in  programming  mode  it  selects a parameter  or confirm an 

operation. 

  (DEF) 

To start a manual defrost 

 

  (UP):  To  see  the  max.  stored  temperature;  in  programming  mode  it  browses  the parameter 

codes or increases the displayed value. 

 (DOWN) To see the min stored temperature; in programming mode it browses the parameter 

codes or decreases the displayed value. 

 

To switch the instrument off, if onF = oFF.  

 

Not enabled. 

KEY COMBINATIONS: 

  

 



To lock & unlock the keyboard. 

 

+

  

 

To enter in programming mode. 

  

+

  

 

To return to the room temperature display. 

4.1

 

USE OF LEDS 

Each LED function is described in the following table. 

LED 

MODE 

FUNCTION 

 

ON 

Compressor enabled 

 

Flashing 

Anti-short cycle delay enabled 

 

ON 

Defrost enabled 

 

Flashing 

Drip time in progress 

 

ON 

An alarm is occurring 

 

ON 

Continuous cycle is running 

 

ON 

Energy saving enbled 

°C/°F  ON 

Measurement unit 

°C/°F  Flashing 

Programming phase 

5.

 

MAX & MIN TEMPERATURE MEMORIZATION 

5.1

 

HOW TO SEE THE MIN TEMPERATURE 

1. 

 

Press and release the 

n

 key. 

2. 

 

The “Lo” message will be displayed followed by the minimum temperature recorded. 

3. 

 

By pressing the 

n

 key again or by waiting 5s the normal display will be restored. 

5.2

 

HOW TO SEE THE MAX TEMPERATURE 

1. 

 

Press and release the 

o

 key. 

2. 

 

The “Hi” message will be displayed followed by the maximum  temperature recorded. 

3. 

 

By pressing the 

o

 key again or by waiting 5s the normal display will be restored. 

5.3

 

HOW TO RESET THE MAX AND MIN TEMPERATURE RECORDED 

1.

 

Hold press the SET key for more than 3s, while the max. or min temperature is displayed. (rSt 
message will be displayed) 

2.

 

To  confirm  the  operation  the  “rSt”  message  starts  blinking and the normal temperature will be 
displayed. 

6.

 

MAIN FUNCTIONS 

6.1

 

HOW TO SEE THE SETPOINT 

 

1.

 

Push and immediately release the SET key: the display will show the Set 
point value; 

2.

 

Push and immediately release the SET key or wait for 5 seconds to  

display the probe value again. 

6.2

 

HOW TO CHANGE THE SETPOINT 

1.

 

Push the SET key for more than 2 seconds to change the Set point value; 

2.

 

The value of the set point will be displayed and the “°C” or “°F” LED starts blinking; 

3.

 

To change the Set value push the 

or 

n

 arrows within 10s. 

4.

 

To memorise the new set point value push the SET key again or wait 10s. 

6.3

 

HOW TO START A MANUAL DEFROST 

 

Push the DEF key for more than 2 seconds and a manual defrost will start. 

6.4

 

HOW TO CHANGE A PARAMETER VALUE 

To change the parameter’s value operate as follows:  

Содержание Dixell XR40CX

Страница 1: ...ture probe The HOT KEY output allows to connect the unit by means of the external module XJ485 CX to a network line ModBUS RTU compatible such as the dIXEL monitoring units of X WEB family It allows to program the controller by means the HOT KEY programming keyboard The instrument is fully configurable through special parameters that can be easily programmed through the keyboard 3 CONTROLLING LOAD...

Страница 2: ...SET set point dtr percentage of visualization rEd X REP display optional P1 P2 P3 P4 SET dtr it selects which probe is displayed by X REP P1 Thermostat probe P2 Evaporator probe P3 Third probe only for model with this option enabled P4 Fourth probe SET set point dtr percentage of visualization dLy Display delay 0 20 0m risul 10s when the temperature increases the display is updated of 1 C 1 F afte...

Страница 3: ...plies with the instrument s requirements Separate the probe cables from the power supply cables from the outputs and the power connections Do not exceed the maximum current allowed on each relay in case of heavier loads use a suitable external relay 12 1 PROBE CONNECTION The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration It is recommended to plac...

Страница 4: ...L el heater in hot gas EL Pr1 dFP Probe selection for defrost termination nP P1 P2 P3 P4 P2 Pr2 dtE Defrost termination temperature 50 50 C 8 Pr1 IdF Interval between defrost cycles 1 120 ore 6 Pr1 MdF Maximum length for defrost 0 255 min 30 Pr1 dSd Start defrost delay 0 99min 0 Pr2 dFd Displaying during defrost rt it SEt DEF it Pr2 dAd MAX display delay after defrost 0 255 min 30 Pr2 Fdt Draining...

Отзывы: