18 • XR35CX I&O Manual
13 How to Use the
Hot Key
13.1.How to Program a Hot
Key From the
Controller (Upload)
1. Program one controller using the front keypad.
2. When the controller is ON, insert the Hot Key into
the 5-pin receptacle and push the up arrow button;
the
uPL
message appears followed by a flashing
End
LED.
3. Push the SET
button and the
End
LED will stop
flashing to indicate the upload has been successful.
4. Turn OFF the controller, remove the Hot Key,
then
turn it ON again.
13.2.How to Program the
Controller Using a Hot
Key (Download)
1. Turn OFF the controller by pressing the on/off but-
ton
for 5 seconds.
OFF
will display.
2. Insert a
programmed Hot Key into the 5-pin recep-
tacle
and then turn the Controller ON by pressing
the on/off button again for 5 seconds. The normal
temperature value will display to indicate the con-
troller is ON.
3. Automatically, the parameter list of the Hot Key
is
downloaded into the controller memory; the
doL
message will display followed by
End
at the end of
the data transfer phase if the controller is pro-
grammed correctly.
4. After 10 seconds, the controller will restart working
with the new parameters.
5. Remove the Hot Key.
NOTE: The Err message is displayed in case of
an error or failure in programming. In this
case push the up arrow button again if you
want to restart the upload or remove the Hot
Key to abort the operation.
NOTE: The Err message is displayed in case of
an error or failure in programming. In this
case, turn the unit OFF and then ON if you
want to restart the download or remove the Hot
Key to abort the operation.