Emerson DESIGNER REMOTE CF759AB00 Скачать руководство пользователя страница 9

9

Trouble Shooting

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit 

breakers.

2. Loose power line connections to the fan, or loose 

2. Check line wire connections to fan and switch

switch wire connections in the switch housing.

wire connections in the switch housing.

WARNING

: Make sure main power is turned off.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way 

to one side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Loose screws in motor housing.

2. Check to make sure all screws in motor housing

are snug (not over-tight).

3. Screws securing fan blade flanges to motor hub 

3. Check to make sure the screws which attach

are loose.

the fan flanges to the motor hub are tight. 

4. Switch housing binding against blade hub.

4. Check to make sure that the switch housing

does not bind against the blade hub.

5. Wire connectors inside switch housing rattling.

5. Check to make sure wire connectors in

switch housing are not rattling against each 
other or against the interior wall of the switch 
housing.

WARNING

: Make sure main power is turned off.

6. Motor noise caused by solid-state variable

6. Some fan motors are sensitive to signals from

speed control.

Solid-State variable speed controls. If Solid-
State Control is used and motor noise results
choose an alternative control method.

7. Screws holding blades to flanges are loose.

7. Tighten screws securely.

3. Fan wobbles

1. Screws securing fan blade flanges to motor hub 

1. Check to be sure screws which attach the fan  

excessively.

are loose.

blade flanges to the motor hub are tight.

2. Fan blade flanges not seated properly.

2. Check to be sure the fan blade flanges seat 

firmly and uniformly to the surface of the motor 
hub. If flanges are seated incorrectly, loosen the 
flange screws and retighten according to the 
procedure in the section on "How to Put Your 
Ceiling Fan Together".

3. Hanger bracket and/or ceiling outlet box is not    

3. Tighten the hanger bracket screws to the outlet 

securely fastened.

box, and/or secure outlet box. 

4. Fan blades out of balance.

4. Interchanging an adjacent (side-by-side) blade 

pair can redistribute the weight and result in
smoother operation.

WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER

BEFORE TROUBLE SHOOTING YOUR FAN.

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Maintenance

Accessories

1. Ceiling Fan Light Kits (see store or catalog).
2. Downrod Kits (see store or catalog).

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

WARNING

!

WARNING

!

!

!

!

Содержание DESIGNER REMOTE CF759AB00

Страница 1: ...product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Co...

Страница 2: ...only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceil...

Страница 3: ... a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly LOOSE PARTS BAG...

Страница 4: ...pling cover are both oriented correctly Figure 3 4 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the...

Страница 5: ... screws re engage and reseat the flanges then tighten the screws again 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades BLADE ASSE...

Страница 6: ... contact a licensed electrician for advice as it must be grounded for safe operation WARNING How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 9 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wob...

Страница 7: ...itters ALL fans set to different frequencies c Interference with other household systems such as your garage door opener NOTE If you change the operating frequency you must change both the transmitter and receiver to the same frequency The remote control will not operate unless both the transmit ter and receiver are set at the same frequency Setting Transmitter Frequency 1 Remove battery cover and...

Страница 8: ... light ON or OFF press and release the LIGHT DIMMER button The light will turn ON at the light level previously set See Step 4 Red light turns on when any button is pressed If the light does not come on replace your battery 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Remove the battery cover by pressing firmly on the arrow and sliding the cover...

Страница 9: ... screws which attach the fan excessively are loose blade flanges to the motor hub are tight 2 Fan blade flanges not seated properly 2 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 3 Hanger brack...

Страница 10: ...ransmitter 762023 762023 762023 762023 762023 762023 762023 16 Control Receiver 762036 762036 762036 762036 762036 762036 762036 17 Switch Housing 762024 3 762024 1 762024 4 762024 6 762024 5 762024 2 762024 18 Blade set of 5 761859 8 761859 8 761859 5 761859 16 761859 17 761859 6 761859 22 19 Flange set of 5 761901 761901 1 761901 4 761901 11 761901 9 761901 8 761901 5 Owner s Manual BP7240 1 BP7...

Отзывы: