Emerson DESIGNER REMOTE CF759AB00 Скачать руководство пользователя страница 6

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1. Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire
connector supplied (Figure 12).

NOTE: If you are using an Emerson Light Fixture
with your fan, refer to Light Fixture Owner’s
Manual for wiring.

2. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 12). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
12). After connections have been made, turn leads
upward and carefully push leads into the outlet box,
with the white and green leads on one side of the

outlet box and the black and blue leads on the
other side of the outlet box.

6

How to Wire

Your Ceiling Fan

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 11

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

WARNING

!

How to Hang Your

Ceiling Fan

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 9).

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 2

AT LEAST

7'

CEILING

FLOOR

Figure 9

Figure 10

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician in in doubt.

To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.

The outlet box must be securely anchored and
capable of withstanding a load of at least 50 lbs.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

1.Securely attach the hanger bracket to the outlet box

using the two screws supplied with the outlet box.
(Figure 10.)

2. Carefully lift the fan and seat the hanger ball/down-

rod assembly on the hanger bracket that was just
attached to the outlet box (Figure 11). Be sure the
groove in the ball is lined up with tab on the hanger
bracket (Figure 10).

Содержание DESIGNER REMOTE CF759AB00

Страница 1: ...product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Co...

Страница 2: ...only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceil...

Страница 3: ... a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly LOOSE PARTS BAG...

Страница 4: ...pling cover are both oriented correctly Figure 3 4 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the...

Страница 5: ... screws re engage and reseat the flanges then tighten the screws again 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades BLADE ASSE...

Страница 6: ... contact a licensed electrician for advice as it must be grounded for safe operation WARNING How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 9 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wob...

Страница 7: ...itters ALL fans set to different frequencies c Interference with other household systems such as your garage door opener NOTE If you change the operating frequency you must change both the transmitter and receiver to the same frequency The remote control will not operate unless both the transmit ter and receiver are set at the same frequency Setting Transmitter Frequency 1 Remove battery cover and...

Страница 8: ... light ON or OFF press and release the LIGHT DIMMER button The light will turn ON at the light level previously set See Step 4 Red light turns on when any button is pressed If the light does not come on replace your battery 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Remove the battery cover by pressing firmly on the arrow and sliding the cover...

Страница 9: ... screws which attach the fan excessively are loose blade flanges to the motor hub are tight 2 Fan blade flanges not seated properly 2 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 3 Hanger brack...

Страница 10: ...ransmitter 762023 762023 762023 762023 762023 762023 762023 16 Control Receiver 762036 762036 762036 762036 762036 762036 762036 17 Switch Housing 762024 3 762024 1 762024 4 762024 6 762024 5 762024 2 762024 18 Blade set of 5 761859 8 761859 8 761859 5 761859 16 761859 17 761859 6 761859 22 19 Flange set of 5 761901 761901 1 761901 4 761901 11 761901 9 761901 8 761901 5 Owner s Manual BP7240 1 BP7...

Отзывы: