Emerson DESIGNER REMOTE CF759AB00 Скачать руководство пользователя страница 4

4

How to Put Your Ceiling

Fan Together

1. Remove the hanger ball by loosening the setscrew

in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.

2. Separate, untwist and unkink the three 80” motor

leads. Route the motor lead wires through the
downrod. Remove the upper setscrew from the
motor coupling. Align the clevis pin holes in the
downrod with the holes in the motor coupling.
Install the clevis pin and secure with the hairpin
clip (Figure 2). The clevis pin must go through the
holes in the motor coupling and the holes in the
downrod. Be sure to push the straight leg of the
hairpin clip through the hole near the end of the
clevis pin until the curved portion of the hairpin clip
snaps around the clevis pin. The hairpin clip must
be properly installed to prevent the clevis pin from
working loose. Pull on the downrod to make sure
the clevis pin is properly installed. Reinstall the
upper setscrew in the motor coupling. Check that
the lower setscrew is tightened securely (Figure 2).

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

3. Make sure the grommet is properly installed in the

coupling cover, then slide the coupling cover on
the downrod until it rests on the motor housing.
Place the ceiling cover over the downrod. Be sure
that the ceiling cover and the coupling cover are
both oriented correctly (Figure 3).

4. Reinstall the hanger ball (Figure 4) on the downrod

as follows. Route the three 80” motor leads through
the hanger ball. Position the pin through the two
holes in the downrod and align the hanger ball so the
pin is captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin and
securely tighten the setscrew in the hanger ball.
A loose setscrew could create fan wobble.

5.The fan comes with blue, black and white leads that

are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

6. Engage the connector of the switch housing

assembly with the motor connector (Figure 5). The
two connectors are keyed and color-coded and
must be mated correctly (color-to-color) before
they can be engaged. Make sure the connector
latch closes properly.

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

PIN

SETSCREW

HANGER
BALL

DOWNROD

Figure 1

MOTOR COUPLING

HAIRPIN
CLIP

CLEVIS
PIN

UPPER
SETSCREW

CLEVIS
PIN

SETSCREW

HAIRPIN
CLIP

MOTOR
COUPLING

SETSCREW

CLEVIS PIN

DOWNROD

Figure 2

CEILING
COVER

COUPLING COVER

PIN

SETSCREW

HANGER
BALL

DOWNROD

Figure 4

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

Figure 3

Содержание DESIGNER REMOTE CF759AB00

Страница 1: ...product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Co...

Страница 2: ...only U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceil...

Страница 3: ... a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proceeding 2 Remove the fan assembly from the protective plas tic bag Place the fan assembly into the upper foam pad with the bottom of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly LOOSE PARTS BAG...

Страница 4: ...pling cover are both oriented correctly Figure 3 4 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the...

Страница 5: ... screws re engage and reseat the flanges then tighten the screws again 12 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan To reduce the risk of personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades BLADE ASSE...

Страница 6: ... contact a licensed electrician for advice as it must be grounded for safe operation WARNING How to Hang Your Ceiling Fan The fan must be hung with at least 7 of clearance from floor to blades Figure 9 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wob...

Страница 7: ...itters ALL fans set to different frequencies c Interference with other household systems such as your garage door opener NOTE If you change the operating frequency you must change both the transmitter and receiver to the same frequency The remote control will not operate unless both the transmit ter and receiver are set at the same frequency Setting Transmitter Frequency 1 Remove battery cover and...

Страница 8: ... light ON or OFF press and release the LIGHT DIMMER button The light will turn ON at the light level previously set See Step 4 Red light turns on when any button is pressed If the light does not come on replace your battery 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Remove the battery cover by pressing firmly on the arrow and sliding the cover...

Страница 9: ... screws which attach the fan excessively are loose blade flanges to the motor hub are tight 2 Fan blade flanges not seated properly 2 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 3 Hanger brack...

Страница 10: ...ransmitter 762023 762023 762023 762023 762023 762023 762023 16 Control Receiver 762036 762036 762036 762036 762036 762036 762036 17 Switch Housing 762024 3 762024 1 762024 4 762024 6 762024 5 762024 2 762024 18 Blade set of 5 761859 8 761859 8 761859 5 761859 16 761859 17 761859 6 761859 22 19 Flange set of 5 761901 761901 1 761901 4 761901 11 761901 9 761901 8 761901 5 Owner s Manual BP7240 1 BP7...

Отзывы: