(1) Above dimensions subject to change without notice.
(2) Weight is without preamplifier assembly. Add 4 lbs. for each preamplifier assembly.
1.2
Specifications for "PT" Meters
“PT” Meter, rim and blade type, when installed with meter tube and calibrated on water.
straightening sections and
Linearity:
3" and larger:
•
±0.25% normal linearity
•
±0.5% over extended minimum to extended maximum flow range
•
±0.15% premium linearity
•
±0.10% p linearity
•
±0.07% p+ linearity
Repeatability:
±0.02% at any point throughout the extended minimum to extended maximum flow range
Pressure Drop:
At maximum flow of normal flow range on water 4 psi
Pressure Range:
ANSI 150-1500# depending upon size
Viscosity:
High viscosities will reduce flow range of meter. Consult Daniel Measurement engineers.
Pickup Coil:
Nominal open circuit peak to peak voltage output:
Blade
Rimmed
Minimum flow
4.0v
5.0v
Maximum flow
0.3v
0.1v
Materials of construction
Table 1-2:
Item
Standard
Optional
Meter body
304SS
316SS
Flanges (slip on)
Carbon steel
304SS or 316SS
Suspension
304SS
316SS
Dimensions and specifications of the meter
Installation and maintenance instructions
3
Содержание Daniel PT Series
Страница 8: ......
Страница 10: ...Contents ii PT Liquid Turbine Meters ...
Страница 18: ...Dimensions and specifications of the meter 8 PT Liquid Turbine Meters ...
Страница 30: ... PT Meter exploded assembly Figure 4 1 General information about the meter 20 PT Liquid Turbine Meters ...
Страница 36: ...Step 7 Figure 5 7 8 Remove hanger blades from hanger hub Meter Disassembly 26 PT Liquid Turbine Meters ...
Страница 46: ...Meter Disassembly 36 PT Liquid Turbine Meters ...
Страница 62: ...Flow direction and flange ratings Figure 7 2 Inspection 52 PT Liquid Turbine Meters ...
Страница 64: ...Inspection 54 PT Liquid Turbine Meters ...
Страница 65: ...Inspection Installation and maintenance instructions 55 ...
Страница 66: ...Inspection 56 PT Liquid Turbine Meters ...
Страница 67: ...Inspection Installation and maintenance instructions 57 ...