Introduction
This installation guide provides instructions for installation,
startup and adjustment. To receive a copy of the instruction
manual, contact your local Sales Office or view a copy
at www.fisher.com. For further information refer to:
CSB600 Series Commercial / Industrial Pressure Reducing
Regulators Instruction Manual, D103130X012.
PED Categories
This product may be used as a pressure accessory with
pressure equipment in the following Pressure Equipment
Directive. For information on the current PED revision see
. Pressure regulator does not require
any supplementary upstream safety accessory for protection
against overpressure compared with its design pressure
PS, when upstream reducing station is sized for a max
downstream incidental MIPd <= 1.1 PS.
tyPE
DEsCrIPtIon
PED CatEgory
FluID grouP
CSB600, CSB600F,
CSB620, CSB620F
and CSB650
Base regulator
I
Groups 1 and
2 according to
PED 2014/68/EU
1st and 2nd family
gas according to
EN 437 or other
gases (compressed
air, Nitrogen). The
gas must be non-
corrosive, clean
(filtration on inlet side
necessary) and dry.
CSB604, CSB604F,
CSB624, CSB624F
and CSB654
Regulator with
slam shut
IV
European En reference standards
EN 334 and
EN 14382
specifications
available Configurations
See Table 1
regulator type
Differential Strength (DS)
accuracy Class
Up to AC5 (depending on Outlet Pressure)
lockup Class
Up to SG10 (depending on Outlet Pressure)
Failure Mode per En334
Fail Open (FO)
Integral strength (Is) Pressure rating
(1)
See Table 2
Differential strength (Ds) Pressure ratings
(1)
See Table 3
Body sizes, Materials, End Connections and
Pressure ratings
(1)
See Table 4
operating Pressure range
(1)
regulator:
See Table 5
slam-shut Module:
See Tables 7a, 7b, 7c and 7d
Maximum outlet Pressure
(1)
Emergency Casing:
Type CSB600/CSB600F/CSB620/CSB620F:
4.0 bar / 58.0 psig
Type CSB650:
5.0 bar / 72.5 psig
to avoid Internal Metallic Parts Damage:
Type CSB600/CSB600F/CSB620/CSB620F:
0.34 bar / 5.0 psig over set pressure
Type CSB650:
1.5 bar / 21.8 psig – not to exceed
maximum emergency outlet
operating Casing:
Types CSB600 and CSB620:
1.1 bar / 16.2 psig
Type CSB650:
5.0 bar / 72.5 psig
outlet Pressure ranges
(1)
9.0 mbar to 4.0 bar / 0.13 to 58.0 psig
See Table 5
orifice size
25 mm / 1.0 in.
Pressure registration
External
temperature Capabilities
(1)(2)(3)
according to PED standards:
-20 to 66°C / -4 to 151°F
non-PED:
-30 to 66°C / -22 to 151°F
spring Case Vent Connection
1 nPt:
Types CSB600 and CSB620
1/2 nPt:
Type CSB650
type VsX8 slam-shut Device Maximum Inlet
Pressure (P
umax
)
(1)
:
Differential strength (Ds):
16 bar / 232 psig
Integral strength (Is):
6.0 bar / 87 psig
approximate Weights
with threaded body
Type CSB600/CSB620:
13 kg / 29 lbs
Type CSB650:
14 kg / 31 lbs
Type CSB604/CSB624:
14 kg / 31 lbs
Type CSB654:
15 kg / 33 lbs
with Flanged body
Add 5.2 kg / 11 lbs to weights listed
Designed, tested and Evaluated Consistent With:
ANSI B16, ASME BPVC Sec. VIII Div. I, ASTM B117
(Corrosion Resistance), EN 334 and EN 14382
Directive atEX Information
See Table 6
For information about ATEX, refer to CSB600 Series
(D103130X012) and VSX8 Series
(D103127X012) Instruction Manuals.
1. The pressure/temperature limits in this Installation Guide or any applicable standard limitation should not be exceeded.