Ceiling Fan Assembly
5
emersonfans.com
Please contact 1-800-654-3545 for further assistance
U.L. Model No.: CF1
HANGER BALL
PIN
DOWNROD
SETSCREW
Figure 1
MOTOR
COUPLING
CLEVIS PIN
HAIRPIN
CLIP
CONNECTED
RED LEADS
CONNECTED
BROWN LEADS
WHITE LEAD
DOWNROD
SETSCREW
CLEVIS PIN
MOTOR
COUPLING
DOWNROD
HAIRPIN
CLIP
Figure 2
MOTOR LEADS
(BLACK, WHITE,
AND BLUE)
SETSCREW
WRENCH
FAN MOTOR AND
HOUSING ASSEMBLY
DOWNROD
Figure 3
1.
Remove the fan motor and housing assembly from
styrofoam packaging and position it so that the top of
the motor is facing you.
2.
Remove the hanger ball from the downrod by
loosening the setscrew in the hanger ball until the ball
falls freely down the downrod (Figure 1). Remove the
pin from the downrod, then remove the hanger ball.
Retain the pin and hanger ball for reinstallation in
Step 9.
3.
Separate, untwist and unkink the three motor leads.
Route the motor leads through the downrod and seat
the downrod in the motor coupling (Figure 2).
NOTE: If your ceiling height is nine feet or higher,
you may use the 18-inch downrod, along with the
downrod trim and decorative bulb. If your ceiling
height is between eight and nine feet, you must use
the shorter 4-1/2” downrod.
4.
Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin and
secure with the hairpin clip (Figure 3). (Pin and clip
are supplied in loose parts bag.) The clevis pin must
go through the holes in the motor coupling and the
holes in the downrod. Push the straight leg of the
hairpin clip through the hole near the end of the
clevis pin until the curved portion of the hairpin clip
snaps around the clevis pin. The hairpin clip must be
properly installed to prevent the clevis pin from
working loose. Pull up on the downrod to make sure
the clevis pin is properly installed.
5.
Install the setscrew (supplied) in the motor
coupling (Figure 3). While pulling up on the downrod,
tighten the setscrew using the setscrew wrench
(supplied).
NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.
It is critical that the clevis pin in the motor coupler is
properly installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are properly
installed (as shown in Figure 3) could result in the fan
falling.
WARNING
!