background image

2

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a. Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the
manufacturer.

b. Before servicing or cleaning unit, switch power off

at service panel and lock service panel
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the
service panel.

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned

off at the fuse box before wiring, and do not operate
fan without blades.

2. All wiring must be in accordance with the National

Electrical Code “ANSI/NFPA 70-2011” and Local
Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical
shock. Electrical installation should be made or
approved by a licensed electrician.

3. The outlet box and joist must be securely mounted

and capable of reliably supporting at least 50 pounds.
Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 22.7kg. (50 lbs.) or less”, and use the
mounting screws provided with the outlet box. Most
outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

4. The downrod furnished with the fan provides the

minimum recommended floor to fan blade clearance
for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with
the fan blades.

6. Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed
by a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this

fan must be installed with an isolating wall
control/switch.

NOTE:

This fan is suitable for use with solid-state speed

controls.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson
Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson could
result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

NOTE:

All setscrews must be checked and re-tightened

where necessary before installation.

1. Read your owner’s manual carefully and keep it for

future reference.

2. Be careful of the fan and blades when cleaning,

painting, or working near the fan. Always turn off the
power to the ceiling fan before servicing.

3. Do not put anything into the fan blades while they are

turning.

4. Do not operate reversing switch until fan blades have

come to a complete stop.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record

this data above and keep it in a safe place for future use.

U.L. Model No.: CF1

READ AND SAVE THESE INSTRUCTIONS

Содержание CORNERSTONE CF1AB01

Страница 1: ...E Series Ceiling Fan Owner s Manual Model Numbers CF1AB01 Antique Brass CF1ORB01 Oil Rubbed Bronze CF1PW01 Pewter CF1WB01 Weathered Bronze Net Weight 27 0 Lbs 1 800 654 3545 www emersonfans com Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m EST Monday Friday ...

Страница 2: ...fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical sho...

Страница 3: ...NOTE Before discarding packaging material be certain all parts have been removed 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages of assembly A B C D J K I G H L M E F PACKAGE CONTENTS 1 8 7 4 2 3 5 6 9 10 11 14 12 13 Part Description...

Страница 4: ...support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a...

Страница 5: ...along with the downrod trim and decorative bulb If your ceiling height is between eight and nine feet you must use the shorter 4 1 2 downrod 4 Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 3 Pin and clip are supplied in loose parts bag The clevis pin must go through the holes in the motor coupling and t...

Страница 6: ...tain that the downrod trim seats in the bottom grommet of the decorative bulb 8 Position the ceiling cover trim and the ceiling cover over the downrod Be sure the cover is oriented correctly with the large opening at the top Figure 5 9 Reinstall the hanger ball on the downrod Figure 6 as follows Route the motor leads through the hanger ball and slide the hanger ball over the downrod Install the pi...

Страница 7: ...ange screws to the motor hub working around the hub in a clockwise sequence Next securely tighten all flange screws again working in a clockwise sequence Failure to follow this procedure could result in fan wobble 14 TWO BLADE VERSION Attach one blade assembly to the motor hub using four 10 32 x 5 8 oval head screws supplied Figure 9 Install the other blade assembly in the same manner Gently snug ...

Страница 8: ... 1 2 screws 16 Position the lower trim assembly on the upper cover trim so that the tabs on the lower trim assembly slide into the slots in the upper cover trim Figure 11 Then securely install four 8 32 x 1 2 screws supplied TUR N TU RN 8 32 x1 2 SCREW 2 UPPER COVER TRIM HOLE FOR SPEED CONTROL SWITCH CHAIN SWITCH HOUSING ASSEMBLY LOOKING UP INTO SWITCH HOUSING ASSEMBLY Figure 10 8 32 x 1 2 SCREW 4...

Страница 9: ... commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING The fan must be hung with at least 7 of clearance from floor to blades Figure 12 WARNING 1 Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 13 2 Carefully lift the fan and seat th...

Страница 10: ...ter connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are ...

Страница 11: ...D CONTROL PULL CHAIN SWITCH THREADED NIPPLE LOWER TRIM FINIAL 8 32 x 3 8 SCREW 4 CENTER TRIM Figure 18 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Check the operation of the fan by gently pulling on the 4 position speed control pull chain switch Figure 17 The operating sequence is as follows 3 If airflow is desired in opposite direction turn yo...

Страница 12: ...ols see store or catalog Accessories The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING 12 U L Model No CF1 Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your...

Страница 13: ...re loose 5 Tighten screws securely 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Raise motor cover and tighten setscrew securely excessively 2 Setscrew in hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor hub 3 Check to be sure screws which attach the fan blade flanges to are loose the motor hub are...

Страница 14: ...FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 14 U L Model No CF1 Repair Parts 8 33 12 36 10 5 4 35 25 26 15 18 19 9 21 23 24 11 40 7 38 28 29 31 30 32 22 14 13 37 39 34 6 27 1 2 16 17 3 18 20 19 ...

Страница 15: ...62508 762508 Parts Bag Containing 762462 762462 762462 762462 4 Pin Clevis 1 5 Clip Hairpin 1 13 Coupling 1 14 Pendant 1 16 Wire Connector 5 17 Wrench Setscrew 1 18 Stud Threaded 1 1 4 2 19 Lockwasher 4 20 Knob Knurled 4 21 Screw 10 32 x 5 8 9 22 Screw 8 32 x 1 2 7 23 Screw 10 32 x 3 8 21 24 Washer Flat 21 26 Setscrew 1 27 Stud Threaded 1 2 28 Trim Upper Cover 762084 762084 4 762084 2 762084 1 29 ...

Страница 16: ...an to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or ...

Страница 17: ...17 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF1 Notes ...

Страница 18: ...18 U L Model No CF1 Notes ...

Страница 19: ...19 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No CF1 Notes ...

Страница 20: ...mer Service 8 a m 6 p m EST Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP73270000 Form No BP7327 Revision 130605 U L Model No CF1 Printed in China 06 13 ...

Отзывы: