© 2017 Emerson Climate Technologies, Inc.
25
AE5-1377 R3
Table 5 - Mechanical/Electrical Specifications
Unit Model
Compressor
H.P.
Dimensions (in)
Connection Lines
#
of
Fans
Min Circuit Ampacity/
Max Fuse (Amps)
Pump
Down
Capacity
(lbs)
Unit
Weight
(lbs)
dba *
L
W
H
Suction
Liquid
208/230V
1ph-60hz
208/230V
3ph-60hz
XJAM-015Z
ZS11KAE
1.5
16.7
40.5
33
3/4"
Pre mid-2013
7/8"
Post mid-2013
1/2 "
1
15.2 / 20
N/A
7.5
180
55
XJAM-020Z
ZX15KCE
2
16.7
40.5
33
3/4"
Pre mid-2013
7/8"
Post mid-2013
1/2 "
1
18.7 / 30
11.1 / 15
7.5
182
55
XJAM-030Z
ZX21KCE
3
16.7
40.5
33
3/4"
Pre mid-2013
7/8"
Post mid-2013
1/2 "
1
24.3 / 40
14.7 / 25
7.5
194
55
XJAM-040Z
ZX30KCE
4
16.7
40.5
49
7/8 "
1/2 "
2
32.1 / 50
19.7 / 30
11
250
56
XJAM-050Z
ZX38KCE
5
16.7
40.5
49
7/8 "
1/2 "
2
36.6 / 60
29.0 / 50
11
258
56
XJAM-060Z
ZX45KCE
6
16.7
40.5
49
7/8 "
1/2 "
2
N/A
28.1 / 45
11
270
56
XJAL-020Z
ZXI06KCE
2
16.7
40.5
33
3/4"
Pre mid-2013
7/8"
Post mid-2013
1/2 "
1
19.4 / 30
14.7 / 25
7.5
188
50
XJAL-030Z
ZXI09KCE
3
16.7
40.5
33
3/4"
Pre mid-2013
7/8"
Post mid-2013
1/2 "
1
N/A
15.4 / 25
7.5
192
50
XJAL-035Z
ZXI11KCE
3.5
16.7
40.5
33
7/8 "
1/2 "
1
30.7 / 50
N/A
7.5
213
50
XJAL-040Z
ZXI14KCE
4
16.7
40.5
49
7/8 "
1/2 "
2
36.1 / 60
24.5 / 40
11
251
58
XJAL-050Z
ZXI15KCE
5
16.7
40.5
49
7/8 "
1/2 "
2
N/A
26.1 / 45
11
267
58
XJAL-050Z
ZXI16KCE
5
16.7
40.5
49
7/8 "
1/2 "
2
40.4 / 70
N/A
11
287
58
XJAL-060Z
ZXI18KCE
6
16.7
40.5
49
7/8 "
1/2 "
2
N/A
30.7 / 50
11
291
58
Assume Each Fan @ .75 Amps
*Estimated sound pressure values are 10 feet from the unit at 25F evap for MT and -10 evap for LT at 90 ambient. A sound reduction of up to 3
dBA will occur in ambient temperatures below 70F. This data is typical of ‘free field’ conditions for horizontal air cooled condensing units and
may vary depending on the condensing unit installation. There are many factors that affect the sound reading of a condensing unit such as unit
mounting, reflecting walls, background noise and operating condition.
Table 6 - Emerson Supplied Defrost Set Points
For Models with Mechanical Low Pressure Control and PCB Defrost Module
Switch 1
Defrost duration (minutes)
Switch 2
Time interval between defrost
0
No defrost (manual defrost only)
0
No defrost (manual defrost only)
1
5 minutes
1
1 hour
2
10 minutes
2
2 hours
3
15 minutes
3
3 hours
4
20 minutes
4
4 hours
5
25 minutes
5
5 hours
6
30 minutes
6
6 hours
7
35 minutes
7
7 hours
Содержание Copeland Scroll Series
Страница 9: ... 2017 Emerson Climate Technologies Inc 9 AE5 1377 R3 Figure 1 Nomenclature and Features ...
Страница 10: ... 2017 Emerson Climate Technologies Inc 10 AE5 1377 R3 Figure 2 Physical and Installation Requirements ...
Страница 14: ... 2017 Emerson Climate Technologies Inc 14 AE5 1377 R3 Drawings ...
Страница 15: ... 2017 Emerson Climate Technologies Inc 15 AE5 1377 R3 ...
Страница 16: ... 2017 Emerson Climate Technologies Inc 16 AE5 1377 R3 ...
Страница 17: ... 2017 Emerson Climate Technologies Inc 17 AE5 1377 R3 ...
Страница 18: ... 2017 Emerson Climate Technologies Inc 18 AE5 1377 R3 ...
Страница 19: ... 2017 Emerson Climate Technologies Inc 19 AE5 1377 R3 ...
Страница 20: ... 2017 Emerson Climate Technologies Inc 20 AE5 1377 R3 ...
Страница 21: ... 2017 Emerson Climate Technologies Inc 21 AE5 1377 R3 ...
Страница 22: ... 2017 Emerson Climate Technologies Inc 22 AE5 1377 R3 ...
Страница 23: ... 2017 Emerson Climate Technologies Inc 23 AE5 1377 R3 ...
Страница 39: ...APPENDIX 2 ...