![Emerson Copeland 4MSL-03 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/emerson/copeland-4msl-03/copeland-4msl-03_application-manuallines_101081020.webp)
AGL_Stream_ST_4MTL_4MSL_E_Rev01
17
Variation smaller Ø
Compressor
Displ.
(m³/h)
Flange
Mountings
(mm)
Suction connection
Discharge connection
Transcritical
Subcritical
Inner Ø
brazing
Valve
description
Inner Ø
brazing
Valve
description
4MTL-05
4MSL-03
4.60
45 x 45
1/2"
W17.2 /
ODS 1/2
1/2"
W17.2 /
ODS 1/2
4MTL-07
4MSL-04
6.20
4MTL-09
4MSL-06
7.40
4MTL-12
4MSL-08
9.54
52 x 52
5/8"
W22 /
ODS 5/8
1/2"
W17.2 /
ODS 1/2
4MTL-15
4MSL-12
12.50
4MTL-30
4MSL-15
17.90
4MTL-35
---
22.70
70 x 70
&
52 x 52
1
⅛
"
W35 /
ODS 1
⅛
"
7/8"
W30 /
ODS 7/8
4MTL-40
---
26.80
4MTL-50
---
32.00
Table 10: Variations with smaller tube connections
3.4 Screens
CAUTION
Screen blocking! Compressor breakdown!
Use screens with at least
0.6 mm openings.
The use of screens finer than 30 x 30 meshes (0.6 mm openings) anywhere in the system should be
avoided with these compressors. Field experience has shown that finer mesh screens used to protect
thermal expansion valves, capillary tubes or accumulators can become temporarily or permanently
plugged with normal system debris and block the flow of either oil or refrigerant to the compressor.
Such blockage can result in compressor failure.