background image

7

How to Wire Your Ceiling Fan

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

1. Connect the green grounding lead from the hanger

ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation). Securely connect wires with wire con-
nectors supplied. (Figure 12.)

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.

2. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 12). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied (Figure
12). After connections have been made, turn leads
upward and carefully push leads into the outlet
box, with the white and green leads on one side of
the outlet box and the black and blue leads on the
other side of the outlet box.

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is ground-
ed, contact a licensed electrician for advice, as it
must be grounded for safe operation.

WARNING

!

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

NOTE: CEILING COVER
OMITTED FOR CLARITY.

GROUND
WIRE

LISTED
WIRE
CONNECTOR (3)

GREEN WIRE
(GROUND) FROM
HANGER BRACKET

GREEN WIRE
(GROUND) FROM
HANGER BALL

WHITE SUPPLY
(NEUTRAL)

WHITE FAN
WIRE

BLACK SUPPLY
(HOT)

BLACK AND BLUE
FAN WIRES

Figure 12

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

3. Screw the two threaded studs (supplied) into the

tapped holes in the hanger bracket.

4. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 13).

5. Secure the ceiling cover in place by sliding lock-

washers over the threaded studs and installing the
two knurled knobs (supplied). (Figure 13.) Tighten
the knurled knobs securely until the ceiling cover
fits snugly against the ceiling and the hole in the
ceiling cover is clear of the downrod. Your fan is
now wired to be turned on and off from the fan
switch.

6. Cut the 3-speed switch pull chain to a desired

length (optional). Connect the wood pendant (sup-
plied) to the 3-speed switch pull chain by sliding
the wooden pendant (small hole first) onto the pull
chain. Attach the chain coupling to the end of the
chain and allow the wooden pendant to fall down
over the coupling.

CEILING
COVER

THREADED
STUD

KNURLED KNOB

LOCKWASHERS (2)

Figure 13

To avoid possible fire or shock, make sure that the elec-
trical wires are completely inside the outlet box and not
pinched between the ceiling cover and the ceiling.

WARNING

!

Содержание CF935AB02

Страница 1: ...2 2 2 2 2 2 2 2 CF935GLG02 1 CF935SCB02 ...

Страница 2: ......

Страница 3: ...each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assemb...

Страница 4: ...eiling cover and the coupling cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tig...

Страница 5: ...ectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the con nector latch closes properly 13 Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switc...

Страница 6: ...fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 5...

Страница 7: ... use with this product by Emerson Electric Co could result in personal injury or property damage WARNING NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 Check to see that all connections are tight including groun...

Страница 8: ... motor or the blades and create the possibility of an electrical shock WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the roo...

Страница 9: ... tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are loose 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and u...

Страница 10: ...10 4 9 8 5 7 11 12 13 19 17 16 18 1 2 3 10 6 20 15 14 Repair Parts ...

Страница 11: ...CF935SCB02 CF935GLG02 CF935AB02 CF935BC02 CF935PW02 CF935ORB02 CF935BZH02 763732 SCB 763732 GLG 763732 AB 763732 BC 763732 PW 763732 ORB 763732 BZH SCB SCB GLG GLG ...

Страница 12: ... 1 20 10 ...

Отзывы: