Страница 1: ...2 2 2 2 2 2 2 2 CF935GLG02 1 CF935SCB02 ...

Страница 2: ......

Страница 3: ...each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before pro ceeding 2 Remove the fan assemb...

Страница 4: ...eiling cover and the coupling cover are both oriented correctly Figure 3 6 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tig...

Страница 5: ...ectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the con nector latch closes properly 13 Remove the three switch housing mounting screws Figure 7 from the switch housing plate Position the switch housing assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switc...

Страница 6: ...fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt WARNING The outlet box and joist must be securely mounted and capable of supporting at least 5...

Страница 7: ... use with this product by Emerson Electric Co could result in personal injury or property damage WARNING NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK AND BLUE FAN WIRES Figure 12 Check to see that all connections are tight including groun...

Страница 8: ... motor or the blades and create the possibility of an electrical shock WARNING Energy Efficient Use of Ceiling Fans Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the roo...

Страница 9: ... tighten setscrew securely excessively securely 2 Setscrew in the hanger ball downrod assembly is 2 Tighten the setscrew in the hanger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are loose 3 Check to be sure screws which attach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and u...

Страница 10: ...10 4 9 8 5 7 11 12 13 19 17 16 18 1 2 3 10 6 20 15 14 Repair Parts ...

Страница 11: ...CF935SCB02 CF935GLG02 CF935AB02 CF935BC02 CF935PW02 CF935ORB02 CF935BZH02 763732 SCB 763732 GLG 763732 AB 763732 BC 763732 PW 763732 ORB 763732 BZH SCB SCB GLG GLG ...