Emerson CF705BS04 Скачать руководство пользователя страница 9

9

emersonfans.com

Please contact 1-800-654-3545 for further assistance

U.L. Model No.:  52-ANT

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal injury
or property damage.

WARNING

!

1.

Ceiling Fan Light Kits (see store or catalog).

2.

Ceiling Fan/Light Controls (see store or catalog).

3.

Downrod Extension Kits (see store or catalog).

9. Accessories

The use of any other control not specifically approved
for this fan could result in fire, shock and personal
injury.

WARNING

!

10. Trouble Shooting

WARNING: 

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE

TROUBLE SHOOTING YOUR FAN.

!

TROUBLE

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fan will not start.

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit breakers.

2. Loose power line connections to the fan, or loose 

2. Check line wire connections to fan and switch switch wire

switch wire connections in the switch housing.

connections in the switch housing.wire connections in the switch
housing.

WARNING:

Make sure main power is turned off.

3. Reversing switch in neutral position.

3. Make sure reversing switch position is all the way to one side.

2. Fan sounds noisy.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Screws securing fan blade flanges to motor 

2. Check to make sure the screws which attach the fan flanges to the 

are loose. 

motor are tight. 

3. Wire connectors inside switch housing rattling.

3. Check to make sure wire connectors in switch housing are not

rattling against each other or against the interior wall of the switch
housing.

WARNING: 

Make sure main power is turned off.

4. Motor noise caused by solid-state variable

4. Some fan motors are sensitive to signals from Solid-State variable

speed control.

speed controls. If Solid-State Control is used and motor noise
results choose an alternative control method.

5. Screws holding blades to flanges are loose.

5. Tighten screws securely.

3. Fan wobbles

1. Setscrew and jam nut in motor coupling are not 

1. Raise coupling cover and tighten setscrew and jam nut securely.

excessively.

tightened securely.

2. Setscrew in the hanger ball/downrod assembly is 

2. Tighten the setscrew in the hanger ball/downrod assembly.

loose.

3. Screws securing fan blade flanges to motor are loose. 3. Check to be sure screws which attach the fan blade flanges to the 

motor are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and uniformly to

the surface of the motor. If flanges are seated incorrectly, loosen
the flange screws and retighten according to the procedure in the 
section on "Ceiling Fan Assembly".

5. Hanger bracket and/or ceiling outlet box is not    

5. Tighten the hanger bracket screws to the outlet box, and/or secure

securely fastened

outlet box. 

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can redistribute

the weight and result in smoother operation.

!

!

Содержание CF705BS04

Страница 1: ... Model No 52 ANT Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com CF705BS04 Brushed Steel CF705ORB04 Oil Rubbed Bronze CF705SW04 Satin White CF705WW04 Appliance White Model Numbers Net Weight 16 5 Lbs ...

Страница 2: ...of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician WARNING To reduce the risk of electrical shock this fan must be installed with an isolating wall control switch WARNING To avoid fire shock or injury do not use an Emerson or any other brand of control not specifically approved for this fan WARNING This product is designed...

Страница 3: ...BLADES BLADE FLANGES CEILING COVER HANGER BALL DOWNROD ASSEMBLY 3 emersonfans com Please contact 1 800 654 3545 for further assistance U L Model No 52 ANT 1 Unpacking Instructions This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designa...

Страница 4: ...at the main fuse box at this time and remove the existing light fixture 4 U L Model No 52 ANT 3 Ceiling Fan Assembly 1 Pass the 42 motor leads through the opening in the ceiling cover Be sure the cover is oriented correctly Figure 1 2 Separate untwist and unkink the three motor leads Route the motor leads through the hanger ball downrod assembly 3 Loosen the two screws in the motor coupling Align ...

Страница 5: ...s are tightened Repeat this procedure for the other four blade assemblies 9 The blade flanges have an interlocking feature that must be fully engaged before tightening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tight...

Страница 6: ... using the two screws supplied with the outlet box Figure 7 2 Carefully lift the fan and seat the hanger ball downrod assembly on the hanger bracket that was just attached to the outlet box Figure 8 Be sure the groove in the ball is lined up with tab on the hanger bracket Figure 7 Figure 6 Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until brac...

Страница 7: ...f the outlet box is grounded contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could ...

Страница 8: ...ree cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish 7 Maintenance Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mo...

Страница 9: ...crews securing fan blade flanges to motor 2 Check to make sure the screws which attach the fan flanges to the are loose motor are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid ...

Страница 10: ...10 U L Model No 52 ANT 11 Repair Parts 18 10 9 16 17 15 13 12 8 7 6 4 5 1 2 3 11 14 ...

Страница 11: ...ORB04 CF705BS04 Hanger Ball Assembly 761655 761655 92 761655 32 761655 17 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod Parts Bag Containing 762897 3 762897 3 762897 762897 1 4 Wire Connector 3 5 Threaded Stud 2 7 Lockwasher 2 8 Knurled Knob 2 9 Pin Clevis 10 Clip Hairpin 12 Coupling Chain 13 Wood Pendant 14 Flange Screw with Lockwasher M6 x 14 1 17 Screw M5 x 6 Washer Head 16 6 Ceiling C...

Страница 12: ...6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returning your Emerson Ceiling Fan to your place of purchase or upon calling Emerson Customer Service If you call Emerson Customer Service prior to...

Отзывы: