Emerson CASH VALVE B Скачать руководство пользователя страница 1

CASH VALVE™

 TYPE B 1 ¼" - 2" PRESSURE REGULATOR

OXYGEN SERVICE INSTALLATION INSTRUCTION

Before installation, these instructions must be read carefully and understood. 

DESCRIPTION

The Type B pressure reducing and regulating 
valve automatically reduces a high inlet 
pressure to a lower delivery pressure and 
maintains the lower pressure within reasonably 
close limits regardless of the pressure 
fluctuations on the inlet side of the valve.

SPECIFICATION DATA

Service:

 Oxygen gas (including medical 

grade oxygen)

Sizes:

 1 ¼, 1 ½ and 2" (32, 38 and 51 mm)

Connections:

 Threaded internal inlet and outlet

Body Material: 

Bronze

Temperature Rating:

 +150 to -320°F 

(65.6 to -195.6°C)

Maximum Initial Pressure:

 400 psi (27.58 bar)

Capacity:

 For specific capacity information, 

consult the factory.

GENERAL INSTALLATION INSTRUCTIONS

The Type B regulator should be installed in the 
horizontal position with the spring chamber 
upright. For other installation requirements, 
consult the factory. For easy operation and 
maintenance, it is suggested that manual 
shut-off valves be installed upstream and 
downstream from the valve. Before installing 
the valve, all piping should be thoroughly 
flushed out to remove any foreign material. 
Install the valve with the inlet pipe fitted to 
the inlet connection identified on the valve 
body. Use a compatible sealant on the male 
pipe threads and do not over tighten the 
valve connections.

CONSTRUCTION

Bronze body, brass internal trim, Buna-N 
diaphragms and seat, Stainless steel 
pressure spring.

All parts are commercially cleaned for 
oxygen service.

OPERATING INSTRUCTIONS

Adjusting the Delivery Pressure

The regulator’s delivery pressure setting is 
adjusted by turning the Adjusting Screw (2) or 
optional T-Handle (1) at the top of the Spring 
Chamber (5) after loosening the Adjusting 
Screw Lock Nut (3). To increase the delivery 
pressure, turn the adjusting screw clockwise 
(into the spring chamber). To decrease the 
delivery pressure, turn the adjusting screw 
counter-clockwise (out of the spring chamber). 
Tighten the adjusting screw lock nut after the 
adjustment has been made. 

MAINTENANCE INSTRUCTIONS

CAUTION

Before attempting to replace any spare parts, be 
sure to shut off all pressure connections to the 
valve. With the valve closed, the system pressure 
could still be locked between the shut-off valve 
and the inlet and/or outlet sides of the regulator. 
Before proceeding with any valve service, be 
certain to relieve the pressure from both sides of 
the regulator.

Refer to section view for parts identification.  
Repair parts can easily be installed without 
removing the regulator from the line. 

Emerson.com

© 2018 Emerson. All rights reserved.

VCIOM-10800-EN 22/01

WARNING

Failure to follow these instructions or to properly 
install and maintain this equipment could result in 
an explosion, fire and/or chemical contamination 
causing property damage and personal injury or 
death. 

Cash Valve regulators must be installed, operated 
and maintained in accordance with federal, 
state and local codes, rules and regulations 
and Emerson Process Management Regulator 
Technologies, Inc. (Emerson) instructions. 

If the regulator vents gas or a leak develops in 
the system, service to the unit may be required. 
Failure to correct trouble could result in a 
hazardous condition. Installation, operation 
and maintenance procedures performed by 
unqualified personnel may result in improper 
adjustment and unsafe operation. Either condition 
may result in equipment damage or personal 
injury. Only a qualified person shall install or 
service the B Series regulator.

CALIFORNIA PROPOSITION 65 WARNING

This product can expose you to chemicals 
including lead, which is known to the State of 
California to cause cancer, birth defects, or other 
reproductive harm. For more information, go to 
www.P65Warnings.ca.gov.

INTRODUCTION

 Scope of the Manual

This manual provides instructions for the 
installation, adjustment, and maintenance for 
the B Series pressure regulators. 

Отзывы: