Wall Control Installation

(continued)

NOTE: Make all wiring connections using wire
connectors (supplied). Make sure that all
connections are tight, including ground, and that
no bare wire is visible at the wire connectors,
except for the ground wire.

1.

Disconnect electrical power to the branch circuit at
the circuit breaker or fuse box before attempting to
install the ceiling fan wall control into the outlet box.

2.

Remove faceplate and screws from existing wall
control. Pull control out from the wall box.
Determine the “hot” wire and the “load” wire and
disconnect these wires from control. Do not attempt
to disconnect any wires not already connected to
existing control.

3.

Before installing wall control, place wall control in
“OFF” mode by pushing “ON/OFF” switch to the
“OFF” position.

4.

Connect one black wire of wall control to the “hot”
wire. Securely connect wires with wire connectors
supplied (Figure 17).

5.

Connect one black wire of wall switch to the “load”
(black) wire in wall box. Securely connect wires
with wire connector supplied. 

6.

Screw wall control into wall box using the supplied
screws.  Leave wall control in “OFF” mode until fan
installation is completed.

13

ETL Model No.: CF788

Do not connect any neutral (white) wire to this
control. Incorrect wiring will damage this control.

WARNING

!

Check to see that all connections are tight and that
no bare wires are visible at the wire connectors.

WARNING

!

7.

The wall control is supplied with a white, ivory, and
almond color switch covers. Choose the finish that
best suits your needs and snap the cover onto the
wall control (Figure 17).

8.

Install decorator wall plate using the two screws
provided with wall plate. Leave wall control in
“OFF” mode until fan installation is completed
(Figure 17).

FAN/LIGHT 
WALL CONTROL

WALL BOX

BLACK

BLK

HOT

SWITCH 
COVER

DECORATIVE 
WALL PLATE

SCREWS (2)

TO 1

20VAC SOURC

E

TO LOAD

G

RO

UN

D

Figure 17

3-WAY INSTALLATION

(One fan controlled by two different wall controls)
(See Figures 18 and 19.)

1.

Disconnect electrical power to the branch circuit at
the circuit breaker or fuse box before attempting to
install the ceiling fan wall control into the outlet
box. 

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box
before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible
electrical shock.

WARNING

!

Do not connect any neutral (white) wire to this
control. Incorrect wiring will damage this control.

WARNING

!

2.

At all wall box locations remove faceplates and
screws from existing controls. Pull controls out
from wall boxes and determine which wall box
contains the “hot” lead and which wall box contains
the “load” wire. Also, identify traveler wires which
are common to both wall boxes. Disconnect wires
from existing controls only. Do not attempt to
disconnect any wires not already connected to
existing controls. 

3.

Before installing wall control, place wall control in
“OFF” mode by pushing “ON/OFF” switch to the
“OFF” position.

4.

Install a wall control in the wall box containing the
“hot” wire first. Connect the black wire of the wall
control to the “hot” wire. Securely connect wires
with wire connectors supplied.

5.

Connect one black wire of the wall control to both
remaining traveler wires in the wall box and secure
with wire connector supplied.

NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire
Is required (See Figure 19).

Содержание CARRERA GRANDE ECO CF788CK

Страница 1: ... READ AND SAVE THESE INSTRUCTIONS Damp Location Ceiling Fan Owner s Manual CF788AP00 Antique Pewter CF788CK00 Chalk CF788GBZ00 Gilded Bronze CF788ORB00 Oil Rubbed Bronze Model Numbers CARRERA GRANDE ECO 54 60 or 72 Fan Blades Not Included Net Weight 17 2 Lbs ...

Страница 2: ...ht fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 6 Follow the recommended instruct...

Страница 3: ...ort and may need to be replaced Consult a qualified electrician if in doubt WARNING N O TE Remove Rubber D iscard Before Installa N O TA Quitar Los Sopor E m b ala Je Y Tirar Lo 2 Attach the blade flanges to the fan blades 3 Attach the blade flange assembly to the motor hub Installation of Downrod page 8 1 Remove the hanger ball from the downrod 2 Install the downrod to the motor coupling using th...

Страница 4: ...est suits your needs and snap the cover onto the wall control 7 Install decorator wall plate using the two screws provided with wall plate Leave wall control in OFF mode until fan installation is completed ON 1 2 3 4 5 I BLACK BLK HOT TO 120VAC SOURCE TO LOAD G R OUND Installation of Wall Control pages 12 13 14 1 Separate the grounded white neutral and green wires on one side of the outlet box fro...

Страница 5: ...refer to section on proper method of wiring your fan page 10 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use wi...

Страница 6: ...nt To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support...

Страница 7: ...g assembly on the switch housing plate and align the holes in the switch housing assembly with the holes in the plate Secure the switch housing assembly by installing the three 8 32 x 12mm flat head screws supplied Figure 5 SWITCH HOUSING ASSEMBLY 8 32 x 12mm FLAT HEAD SCREW 3 Figure 5 To avoid possible fire or shock do not pinch wires between the switch cup assembly and the switch cup plate WARNI...

Страница 8: ...tscrew is tightened securely Figure 7 PIN SETSCREW HANGER BALL DOWNROD Figure 6 7 Carefully turn partially assembled fan upside down and place in styrofoam form carton in preparation for final installation How to Put Your Ceiling Fan Together continued It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin ...

Страница 9: ...hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 14 You have now completed the assembly of your new ceiling fan You can now proceed with hanging and wiring your fan 9 12 Reinstall the hanger ball Figure 9 on the downrod as follows Route the two 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and alig...

Страница 10: ...BRACKET HANGER BALL DOWNROD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 12 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not secur...

Страница 11: ...tact a licensed electrician for advice as it must be grounded for safe operation NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Check to see that all connections are tight including ground and that no bare wire is visible at the wi...

Страница 12: ... pen or small screwdriver and slide the levers firmly up or down 2 When power is restored after installation of the wall control push and hold the fan OFF button for 3 to 5 seconds to set the code in the receiver 3 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescen...

Страница 13: ...until fan installation is completed Figure 17 FAN LIGHT WALL CONTROL WALL BOX BLACK BLK HOT SWITCH COVER DECORATIVE WALL PLATE SCREWS 2 TO 120VAC SOURCE TO LOAD G R OUND Figure 17 3 WAY INSTALLATION One fan controlled by two different wall controls See Figures 18 and 19 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling f...

Страница 14: ... connectors WARNING 3 WAY WIRING DIAGRAM NEW CONSTRUCTION STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLACK SW605 FAN LIGHT WALL CONTROL TRAVELER WIRE BLK BLK LOAD BLACK GROUND NEUTRAL RECEIVER LOCATED ON TOP OF THE CEILING FAN EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 18 Figure 19 HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL FAN LIGHT WA...

Страница 15: ...TTONS FAN DIRECTION FAN BUTTON POWER INDICATOR LIGHT ON OFF SWITCH O OFF ON Figure 20 IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Do not...

Страница 16: ...s B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Fan Light Fails to Operate Check that the speed switch on the fan is set to or speed Check that the light switch is on Check that the battery is good blue indicator light should light when any button is pressed Check that the receiver is wired properly Check that code switches in the remote cont...

Страница 17: ...rs inside switch housing 4 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrew in motor coupling is loose 1 Tighten both setscrews securely in the motor excessively...

Страница 18: ...18 ETL Model No CF788 Repair Parts 12 1 2 3 15 19 6 5 BLADES SOLD SEPARATELY 18 21 11 14 13 16 17 20 8 10 7 9 4 7 ...

Страница 19: ...ternal Tooth 2 14 Knurled Knob 8 32 2 15 Balancing Kit 1 16 Canopy Ceiling 1 763785 AP 763785 CK 763785 GBZ 763785 ORB 17 Motor Coupling Cover 1 764083 AP 764083 CK 764083 GBZ 764083 ORB 18 Switch Housing 1 764127 AP 764127 CK 764127 GBZ 764127 ORB 19 Flange set of 5 764091 AP 764091 CK 764091 GBZ 764091 ORB 20 Wall Control Transmitter 6 Speed 764088 764088 764088 764088 21 Control Receiver 764087...

Страница 20: ...ter call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bul...