Repair Parts

Before discarding packaging material, be certain all

parts have been removed.

HOW TO ORDER REPAIR PARTS

WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:

• PART NUMBER

• PART DESCRIPTION

• NAME OF ITEM

• MODEL NUMBER

For repair parts, phone 1-800-654-3545.

Содержание BUILDER PLUS CF710AB01

Страница 1: ... AND SAVE THESE INSTRUCTIONS BUILDER PLUS Series Ceiling Fan Owner s Manual Net Weight 19 8 Lbs Net Weight 15 0 Lbs 50 Model No CF711AB01 CF711PB01 CF711AW01 CF711WB01 CF711BS01 CF711WW01 CF711CK01 42 Model No CF710AB01 CF710AW01 CF710BS01 CF710PB01 CF710WW01 CF711 shown ...

Страница 2: ...table for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with th...

Страница 3: ...e provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licen...

Страница 4: ...an is designed to be installed either in the standard manner or in the close to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method I...

Страница 5: ...g If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING Hanging The Ceiling Fan Standard Method Using Hanger Ball Downrod 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 7 The tab on the hanger bracket must seat in the groove in the hanger ball NOTE The hanger bracket must be mounted flush with the ceiling in order for t...

Страница 6: ...pounds Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed...

Страница 7: ...ade screws per blade Figure 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on...

Страница 8: ...WIRES FROM LIGHT FIXTURE AND SECURELY CAP WITH WIRE CONNECTORS Figure 15 CAPTIVE SCREW 2 BLADE FLANGE ALIGNMENT SLOT MOTOR HUB Figure 12 RETAINING CLIP SQUEEZE RETAINING CLIPS TOGETHER AND SLIDE ON GLASS SHADE GLASS SHADE Figure 13 2 Mount one blade assembly to the motor hub by mating the alignment post Figure 11 of the flange with one of the alignment slots in the motor hub Figure 12 Then tighten...

Страница 9: ...ng fan blade flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid stat...

Страница 10: ...ectric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular pur...

Страница 11: ...s Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 ...

Страница 12: ...nd Head 1 17 Rubber Gasket Owner s Manual BP7258 4 BP7258 4 BP7258 4 BP7258 4 BP7258 4 BP7258 4 BP7258 4 Repair Parts Listing Form No BP7258 4 Part No F40BP72580004 Printed in China 11 06 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Model No Key No Description CF710AB01 CF710WW01 CF710AW01 CF710PB01 CF710BS01 Hanger Pack Assembly 762231 762231 1 762231 2...

Отзывы: