72
100-412-196 REV. 06
5. Clean the stud and the threaded hole before reinserting it
6. Apply one drop of Loctite to the stud and insert it into the horn
7. Re-tighten the stud. Use the following torque specifications:
After the Stud has been reinserted, you can reassemble the Horn to the Converter. Follow
the same procedure as found in the Installation section of this manual. See
Table 7.1
Torque Specifications
Stud Size
Torque Specification
Stud EDP Number
3/8-24 x 1-1/4 in
290 in lbs/33 Nm
100-098-121
3/8-24 x 1-1/2 in
290 in lbs/33 Nm
100-098-120
1/2-20 x 1-1/4 in
450 in lbs/51 Nm
100-098-370
1/2-20 x 1-1/2 in
450 in lbs/51 Nm
100-098-123