100-412-196 REV. 06
43
5.5.2 User I/O Connection
The LPX Power Supply is equipped with a standard external connection to allow you to
design and connect your own custom interface for controlling the unit. The User I/O
interface can be useful when you need to activate the LPX Power Supply remotely, for
example, when the operator must start and stop the unit from another room for safety
reasons.
1. All voltages and currents measured with respect to Pin 7, Common, except Seek +/-, which is measured
Pin 8 (+) to Pin 9 (-)
2. Outputs should never drive impedances less than 1.6 K
Ω
Table 5.13
User I/O Pin-Out (DB9F) provided for customer-designed interface
Pin
Function
Signal
Type
Signal Range
Values
1
Alarm/Error Reset
Input
0 V to 24 V ±10%
Apply 0 V to reset
alarms/errors
2
Start/Stop
Input
0 V to 24 V ±10%
Apply +24 VDC to
start/stop the cycle
3
Sonics On
Output
0 V to 24 V ±10%
20 mA
0 V indicates the
function is active
See Register 19 in
.
Cycle Running
End of Cycle Pulse
4
Alarm/Error
Output
0 V to 24 V ±10%
20 mA
0 V indicates an
alarm/error occurred
5
Ready
Output
0 V to 24 V ±10%
20 mA
0 V indicates the
system is ready
6
+24 V Source
Output
0 V to 24 V ±10%
125 mA Max
+24 V Source from
power supply
7
+24 V Return
I/O
Signal
Return
0 V Ground
Return for all pins
8
+External Seek
Input
0 V to 24 V ±10%
Apply +24 VDC to
perform a seek
9
-External Seek
Содержание Branson LPX
Страница 4: ...iv 100 412 196 REV 06 ...
Страница 6: ...vi 100 412 196 REV 06 ...
Страница 8: ...viii 100 412 196 REV 06 ...
Страница 10: ...x 100 412 196 REV 06 Table 7 2 System Trouble Analysis Chart 73 Table 7 3 Alarms Errors 76 ...
Страница 24: ...14 100 412 196 REV 06 ...
Страница 33: ...100 412 196 REV 06 23 Chapter 3 Delivery and Handling 3 1 Delivery and Handling 24 ...
Страница 38: ...28 100 412 196 REV 06 4 1 4 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Страница 76: ...66 100 412 196 REV 06 ...
Страница 85: ...100 412 196 REV 06 75 Figure 7 2 LPX Power Supply Interconnect Diagram ...