How to Put Your Ceiling Fan Together

(continued)

SETSCREW

CLEVIS PIN

MOTOR
COUPLING

DOWNROD

HAIRPIN
CLIP

DOWNROD

HAIRPIN
CLIP

MOTOR
COUPLING

SETSCREW (2)

CLEVIS PIN

Figure 4

PIN

HANGER
BALL

SETSCREW

DOWNROD

Figure 3

#8-32 x .31" PAN 
HEAD SCREW  (3)

FAN MOTOR 
HOUSING

DECORATIVE 
ASSEMBLY

#8-32 x .31" PAN 
HEAD SCREW  (3)

Figure 5

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

WARNING

!

1.

Turn partially assembled ceiling fan upside down in
preparation of upper assembly installation.
Carefully place the partially assembled ceiling fan
on the styrofoam, making sure the blades are
supporting the fans weight on the flanges, not the
blades.

2.

Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 3). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in Step 12.

3.

Loosen setscrews in motor coupling. Separate,
untwist and unkink the four 80” motor leads. Route
the motor lead wires through the downrod. Insert
the downrod into the motor coupling. Align the
clevis pin holes in the downrod with the holes in the
motor coupling. Install the clevis pin and secure
with the hairpin clip (Figure 4). The clevis pin must
go through the holes in the motor coupling and the
holes in the downrod. Be sure to push the straight
leg of the hairpin clip through the hole near the end
of the clevis pin until the curved portion of the
hairpin clip snaps around the clevis pin. The hairpin
clip must be properly installed to prevent the clevis
pin from working loose. Pull on the downrod to
make sure the clevis pin is properly installed.

4.

While pulling up on the downrod, securely tighten
the two setscrews in the motor coupling (Figure 4).

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

5.

Remove the three #8-32 x .31” pan head screws
(retain for future installation) from the top of the fan
motor housing (Figure 5).

6.

Place the upper decorative assembly onto the fan
motor housing, aligning the screw holes. To secure
the upper decorative assembly to the fan motor
housing, reinstall the three #8-32 x .31” pan head
screws (Figure 5).

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

U.L. Model No.: CF440

Содержание BRADDOCK CF440VNB

Страница 1: ... THESE INSTRUCTIONS 54 Ceiling Fan Owner s Manual CF440VNB00 Model Number BRADDOCK Net Weight 29 5 Lbs DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use ...

Страница 2: ...om the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE All setscrews must be checked and re tightened where necessary before installation NOTE This fan is suitable for use with solid state speed contr...

Страница 3: ...s product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or property damage A FAN MOTOR ASSEMBLY B CEILING COVER C COUPLING COVER D UPPER DECORATIVE ASSEMB...

Страница 4: ... electrical shock or personal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING U L Model No CF440 1 Mount blade flanges to fan blades using t...

Страница 5: ...the motor lead wires through the downrod Insert the downrod into the motor coupling Align the clevis pin holes in the downrod with the holes in the motor coupling Install the clevis pin and secure with the hairpin clip Figure 4 The clevis pin must go through the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the e...

Страница 6: ...to 9 inches above top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads CEILING COVER DOWNROD RUBBER GROMMET COUPLER COVER Figure 7 It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING ...

Страница 7: ... must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard 2 Carefully lift the fan and seat the hanger ball downrod assembly onto the hanger bracket that was j...

Страница 8: ...in the hanger bracket 6 Lift the ceiling canopy up to the threaded studs and turn until studs protrude through the holes in the ceiling canopy Figure 14 7 Secure the ceiling canopy in place by sliding lockwashers over the threaded studs and installing the two knurled knobs supplied Figure 14 Tighten the knurled knobs securely until the ceiling canopy fits snugly against the ceiling and the hole in...

Страница 9: ...crew in two 60 watt maximum candelabra base bulbs into the downlight assembly sockets Figure 16 6 Remove the finial nut hex nut and rubber washer from the light kit s threaded nipple Retain for reinstallation 7 Place the lower glass onto the threaded nipple and seat the glass onto the light kit assembly Figure 17 While holding the glass in position tightly re install the rubber washer and hex nut ...

Страница 10: ...nsity and fan speed When the switch is turned back ON the light and fan will resume operation as they were prior to the switch being turned OFF Installation of Battery 1 Remove the battery cover by pressing firmly below the arrow and sliding the cover off the control Figure 18 2 Install two AAA alkaline batteries Setting Operating Frequency of Transmitter Figure 18 Your remote control transmitter ...

Страница 11: ...ote When turning the light on light will illuminate at the previously selected intensity Operation of Reverse Switch All fans are shipped from the factory with the reversing switch positioned to circulate air downward If airflow is desired in the opposite direction turn your fan off and wait for the blades to stop turning then slide the reversing switch to the opposite position and turn fan on aga...

Страница 12: ...n could result in fire shock and personal injury 1 Ceiling Fan Light Controls see store or catalog 2 Downrod Extension Kits see store or catalog WARNING WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cl...

Страница 13: ...2 Loose screws in motor housing 2 Check to make sure all screws in motor housing are snug not over tight 3 Wire connectors inside switch housing 3 Check to make sure wire connectors in switch rattling housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned OFF 4 Screws holding blades to motor 4 Tighten screws securely ar...

Страница 14: ...14 Repair Parts 1 7 3 2 9 8 19 5 27 26 24 25 10 11 18 17 16 15 21 13 12 22 23 4 6 14 U L Model No CF440 ...

Страница 15: ...NB 16 Ring Light Kit Retention 1 764226 VNB 17 Upper Glass 1 764222 AMM 18 Upper Decorative Assembly 1 764261 VNB 19 Motor Coupling Cover 1 774100 VNB 20 Wiring Harness Assembly 1 Not Shown 764235 21 Light Kit Assembly 1 764231 VNB 22 Lower Light Kit Glass 1 764233 AMM 23 Finial Nut Hex Nut and Rubber Washer set of 1 764239 VNB 24 Blade Flanges set of 5 764227 VNB 25 Blades set of 5 76429 DM 26 Re...

Страница 16: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...