background image

Emerson Blue Wireless Comfort Interface - Homeowner User Guide  

HOMEOWNER USER GUIDE

1F98EZ-1621 

EMERSON

®

BLUE

™ 

Wireless Comfor t Inter face

Содержание Blue Wireless Easy Install 1F98EZ-1621

Страница 1: ...Emerson BlueWireless Comfort Interface Homeowner User Guide HOMEOWNER USER GUIDE 1F98EZ 1621 EMERSON BLUE Wireless Comfort Interface ...

Страница 2: ...e Sensor s sold separately When Change appears in the display a new set of premium brand AA alkaline batteries should be installed If the house will be unoccupied for an extended period it is recommended that new batteries be installed before leaving Need Help For assistance with this product please call 800 284 2925 Page Overview 3 Quick Start Guide 6 Set CurrentTime and Day 6 Energy Saving Pre P...

Страница 3: ...tor Heat Button A C Button Setting Temperature Day ofWeek Fan Indicator Run Button Menu Button Setting Up Down Fan Button OFF Button Wireless Icon Battery Status Full charge Half capacity Change Replace Batteries Comfort Interface Display Other Display Icons 1 8 9 10 15 12 13 18 19 21 20 22 7 11 14 16 17 5 6 2 4 3 ...

Страница 4: ...icates System is in Auto changeover mode 5 Run identifies button to begin running the program Hold identifies button to press to hold temperature 6 Menu identifies button to press for menus Copy identifies button to copy program in Schedule mode 7 C indicates temperature displayed in Celsius 8 Limit indicates temperature is adjusted to the limit set in the configuration menu 9 Set indicates desire...

Страница 5: ...or sensor is installed instead of time 16 Indicates afternoon PM No indication for Morning AM 17 display is showing Humidity setting instead ofTime of Day 18 Month Year Date displays when setting time and date 19 Call for Service displays when a fault occurs in the system 20 Change Filter Change Pad displays if filter timer or humidifier timer is set and time has expired 21 Searching inWireless Se...

Страница 6: ...fort Interface Homeowner User Guide Quick Start Guide Set CurrentTime and Day 1 On the Home screen press Menu button to display additional selections 2 Press the Time button to display hour and A AM or P PM in the clock display ...

Страница 7: ...art Guide 3 Press the or button to adjust the hour and A AM or P PM 4 Press Time to display the minutes 5 Press the or button to adjust the minutes 6 Press Time to display the year month and day of week 7 Press the or button to adjust 8 Press Run to return to home screen ...

Страница 8: ...erface section on next page Factory Pre Programmed schedule for two period Day Night programs Day Night Heating Program 6 00 AM 70 F 10 00 PM 62 F A C Program 6 00 AM 75 F 10 00 PM 78 F Factory Pre Programmed schedule for four periods per day all days of the week Wake Up Morning Leave For Work Day Return Home Evening GoTo Bed Night Heating Program 6 00AM 70 F 8 00AM 62 F 5 00 PM 70 F 10 00 PM 62 F...

Страница 9: ...rogram the Comfort Interface Keep the following guidelines in mind when planning your program In Heating lower temperatures will save energy In A C higher temperatures will save energy ProgrammingTips Copy Program When programming your Comfort Interface you may copy the program from one day to another day To copy a program 1 In Schedule mode enter the program for the day 2 Press Copy The copied da...

Страница 10: ... SUN 6 00 AM 75 F 8 00 AM 75 F 5 00 PM 75 F 10 00 PM 78 F Worksheet for Re Programming 7 Day Program Heating Program Wake Up Morning Leave For Work Day Return Home Evening GoTo Bed Night MON 6 00 AM 70 F 8 00 AM 62 F 5 00 PM 70 F 10 00 PM 62 F TUE WED THU FRI SAT 6 00 AM 70 F 8 00 AM 70 F 5 00 PM 70 F 10 00 PM 62 F SUN 6 00 AM 70 F 8 00 AM 70 F 5 00 PM 70 F 10 00 PM 62 F Fill in the blank workshee...

Страница 11: ...d period being programmed with the time and temperature The temperature will be flashing to indicate it can be adjusted Enter Heating Program 1 In Heat mode press the Menu button to display additional button selections Program Period Program Temperature Flashing ProgramTime System Mode ProgrammingYour Comfort Interface ...

Страница 12: ...e temperature for that period 4 Press the Time button and use the or button to change the period s start time in 15 minute increments Note If indoor remote sensors are installed proceed to step 5 otherwise skip to step 6 Temperature Setting ProgramTime Flashing ProgrammingYour Comfort Interface ...

Страница 13: ... activate the Comfort Interface s internal temperature sensor A display showing dashes indicates it has been deactivated This setting makes your system rely upon the temperature from the remote sensor s to control temperature ProgrammingYour Comfort Interface CurrentTemperature Flashing Indicates Internal Sensor is Off Indicates Internal Sensor is On ...

Страница 14: ... the previous steps to program the remaining days ProgrammingYour Comfort Interface 6 Press Schedule to advance to the next period Using the Time and or buttons program the remaining periods for that day Note Use the Copy button to copy the currents day s program to any other day see page 9 ...

Страница 15: ...terface Homeowner User Guide Enter A C Program Press A C to place Comfort Interface in air conditioning mode Set the A C program following the previous steps for heating ProgrammingYour Comfort Interface 8 Press Run to exit programming ...

Страница 16: ... Guide OperatingYour System Press Heat or A C button to select Heating or Cooling Press Off to turn Heating or A C off UsingYour Comfort Interface OperatingYour Fan The Fan will run automatically with Heat or Cool To run the fan continuously press Fan button ...

Страница 17: ...Example If you turn up the heat during the morning program it will automatically return to the programmed temperature two hours later UsingYour Comfort Interface PermanentTemperature Hold The PermanentTemperature Hold feature bypasses the program and holds the temperature indefinitely Press the Hold button once The display will show Hold to the left of the temperature setting Press or button to ad...

Страница 18: ...n auxiliary gas heat and turns off the heat pump when the outdoor temperature falls below the user defined Dual Fuel Setpoint To change the Dual Fuel Setpoint see further instructions in Configuration Menu Options menu 21 page 23 Averaging with Indoor Remote Sensor s The Comfort Interface displays the average of the local sensor and any indoor remote sensors unless a device has been deactivated Sy...

Страница 19: ...Temperature Display The Comfort Interface can be configured to display the current humidity inside your home and or the current outdoor temperature if outdoor sensor is installed When turned on the display will cycle time humidity and or outdoor temperature See Configuration Menu Options menu s 11 and 12 page 21 ...

Страница 20: ... view of Comfort Interface Optional Indoor Outdoor Remote Sensors If a sensor is not communicating or the batteries are dead and need to be replaced the Comfort Interface display will alternately flash time temperature and remote sensor number RS1 RS2 RS3 or ORS two dashes Replacing Batteries Replace batteries when Change is displayed ...

Страница 21: ...heck Battery Status for Sensors 1 Press the Menu button once on the Comfort Interface and release 2 Press the Connect button once and release Comfort Interface display will indicate Searching until CTL control is found Remove cover by holding Remote Sensor base and pressing the tab at the bottom while sliding the cover toward the top ...

Страница 22: ...Guide UsingYour Comfort Interface 3 Continue pressing and releasing the Next button to view the battery icon for all remote sensors RS1 RS2 RS3 or ORS If battery needs to be replaced the word Change will be displayed for the remote sensor listed on the screen ...

Страница 23: ...out P partial or L total lockout is selected 03 P7 P0 Program per week P7 7 days P0 non programmable 04 P4 Morn Day Eve Night P2 Program periods per day P4 Morning Day Evening and Night P2 Day Night 2 is also used for commercial applications 05 99 Heat Limit 62 99 Define a maximum heating setpoint Options 62o 99o 06 45 A C Limit 45 82 Define a minimum cooling setpoint Options 45o 82o Configuration...

Страница 24: ...elect Rh setting 40 95 When room humidity is above the selected setting the DHM terminal s will de energize to lower the fan speed whenever there is a call for cool Air speed reduction across the cooling coil allows it to condense removing more humidity 09 OFF Change Filter 1 12 months Displays reminder to change filter after a selected number of months 10 OFF Change Pad Hum 1 12 months Displays r...

Страница 25: ...program time OFF cancels feature 15 0 Temperature 5 Adjusts the temperature displayed on the Comfort Interface by an off set 16 ON LS ON OFF OFF turns the sensor in the Comfort Interface off The room temperature display will come from the remote sensor s only If no wireless remotes are installed this step is skipped 17 OFF b ON OFF ON beeps when any button is pushed OFF cancels the beep 18 ON dL O...

Страница 26: ...t pump Dual Fuel option no outdoor remote sensor required This causes the Comfort Interface to turn off the heat pump shortly after the furnace fires Five 5 is the factory recommended average setting A lower number slightly increases the delay between heat pump and furnace stages A higher number slightly decreases the delay between heat pump and furnace stages Note This setting is not minutes or d...

Страница 27: ...NOTES ...

Страница 28: ...orthAmerica 800 284 2925 EnEspanõl 888 725 9797 InAustralia 1800 057 587 Hours ofOperation NorthAmerica CST U S Canada Mexico 7amto 1am Monday Friday 7amto 4 pm Saturday Sunday Additional Product information can be viewed at http www emersonclimate com en US products thermostats Pages thermostats aspx or http www white rodgers com Australia EasternStandardTime 9 pmto3 pm Monday Friday 9 pmto6 am S...

Отзывы: