Failure or Breakdown Research
Table 8.
Troubleshooting
Event
Possible cause
Remedy
Actuator does not work
Lack of power supply
Restore it
Lack of pneumatic supply
Open line interception valve
Blocked valve
Repair or replace
Wrong position of the distributor of the
hydraulic manual override
Restore correct position
Failure of the control system
Call Emerson Customer Service
Low supply pressure
Restore (Section 1.4)
Actuator too slow
Low supply pressure
Restore (Section 1.4)
Wrong calibration of flow regulator valves
Restore (Section 3.6)
Wear of the valve
Replace
Actuator too fast
High supply pressure
Restore (Section 1.4)
Wrong calibration of flow regulator valves
Restore (Section 3.6)
Leakages on hydraulic
or pneumatic circuits
Deterioration and/or damage to gaskets
Call Emerson Customer Service
Incorrect position of
the valve
Wrong adjustment of mechanical stops
Restore (Section 3.4)
Wrong warning of micro-switches
Restore (Section 3.5)
Hydraulic manual pump
does not work
Handle positioned on remote control
Position the handle on the indication
of the operation to make
Leakages on the check valve of the
hydraulic control group
Call Emerson Customer Service