background image

www.Fisher.com

Baumann

 24000 Little Scotty

 Bronze

Control Valve

Contents

Introduction

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Scope of Manual

1

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Safety Precautions

2

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Maintenance

2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Air Piping

3

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Disassembly

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Actuator Removal

4

. . . . . . . . . . . . . . . . . . . . . . . .

Valve Body Disassembly

5

. . . . . . . . . . . . . . . . . . .

Lapping the Valve Seat

5

. . . . . . . . . . . . . . . . . . . . . . .

Replacing Packing

5

. . . . . . . . . . . . . . . . . . . . . . . . . . .

Actuator and Valve Body Reassembly

5

. . . . . . . . . . .

Parts Ordering

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dimensions and Weights

11

. . . . . . . . . . . . . . . . . . . . . .

Figure 1. 24000 Little Scotty Control Valve with 
Baumann 32 Actuator and FIELDVUE™ DVC2000 
Digital Valve Controller

W9753

Introduction

Baumann Little Scotty industrial control valves (figure 1) are intended for general utility service in pressure, flow, and
temperature control applications.

Industrial grade control valves exhibit low hysteresis and deadband, good control characteristics, tight shutoff, rugged
construction, high performance packing, and easy maintainability. This translates into reduced maintenance costs,
reduced process variability, and increased process availability.

Scope of Manual

This instruction manual includes installation, maintenance, and parts information for the Baumann 24000 bronze
control valve.

Do not install, operate, or maintain Baumann 24000 control valves without being fully trained and qualified in valve,
actuator, and accessory installation, operation, and maintenance. 

To avoid personal injury or property damage, it is

important to carefully read, understand, and follow all the contents of this manual, including all safety cautions and
warnings.

 If you have any questions about these instructions, contact your 

Emerson sales office

 or Local Business

Partner before proceeding.

Instruction Manual

D103355X012

24000 Valve

June 2017

Содержание Baumann 24000 Little Scotty

Страница 1: ...dband good control characteristics tight shutoff rugged construction high performance packing and easy maintainability This translates into reduced maintenance costs reduced process variability and increased process availability Scope of Manual This instruction manual includes installation maintenance and parts information for the Baumann 24000 bronze control valve Do not install operate or mainta...

Страница 2: ...les other than those for which the product was intended If you are not sure what these conditions are you should contact your Emerson Automation Solutions sales office for more complete specifications Provide the product serial numbers shown on the nameplate and all other pertinent information WARNING If you move or work on an actuator installed on a valve with loading pressure applied keep your h...

Страница 3: ...a Note Whenever a gasket seal is disturbed by removing or shifting gasketed parts install a new gasket during reassembly This provides a good gasket seal because the used gasket may not seal properly WARNING Avoid personal injury or property damage by thoroughly cleaning the line of all dirt welding chips scale oil or grease and other foreign material Failure to do so could result in damage to the...

Страница 4: ... by turning the locknuts key 27 with a wrench When placing the valve in a vise clamp the flat end faces of the valve Do not try to clamp the rounded sides of the valve This will ruin the valve Actuator Removal Access to the internal components of the valve body can be accomplished with the actuator removed For actuator maintenance see the following instruction manual Baumann Actuator Instructions ...

Страница 5: ...e valve by applying a slight pressure on the stem and rotate the stem in short oscillating strokes approximately 8 to 10 times or until you see an even and complete lap line The plug should be intermittently lifted and turned 90 degrees while lapping to keep the plug and seat ring concentric 4 Clean the valve seat key 2 and plug key 4 thoroughly when the lapping is complete removing all traces of ...

Страница 6: ...e valve seat This can damage the seating surface very quickly Figure 2 Baumann 24000 Valve Body Assembly with Standard Bonnet and Standard PTFE Spring Loaded Packing E1259 WARNING To avoid personal injury or equipment damage due to possible sudden shifting or falling of the valve assembly do not lift the valve by the handwheel Parts Ordering When corresponding with your Emerson sales office or Loc...

Страница 7: ...4 002 250 49 1 Valve Body Gasket 009191 702 426 009191 702 426 009191 674 426 009191 704 426 009191 705 426 58 1 Travel Indicator 24299 Table 2 Plug and Seat Ring for NPS 1 2 3 4 and 1 Valves KEY NO DESCRIPTION PLUG TYPE PLUG NO ORIFICE DIAMETER mm Inch Cv Kv VALVE SIZE DN 15 NPS 1 2 DN 20 NPS 3 4 DN 25 NPS 1 4 Plug Stem Metal Seat Micro Trim Linear 102 6 3 0 25 0 2 1 0 17 1 GE46388X012 GE46388X09...

Страница 8: ... 0 8125 4 3 4 24757 5 101 648 6 5 16 24717 3 101 648 8 6 88 24717 3 101 648 9 7 74 24717 3 101 648 26 9 1 0625 13 11 18 24791 1 101 648 Metal Seat Linear 688 6 3 0 25 0 5 0 43 GE46396X052 GE46396X092 1 0 0 86 GE46395X062 GE46395X102 9 5 0 375 1 5 1 29 24669 101 688 2 5 2 15 24671 101 688 20 6 0 8125 4 3 4 24757 101 688 6 5 16 24717 101 688 8 6 88 24717 101 688 9 7 74 24717 101 688 26 9 1 0625 13 1...

Страница 9: ... Equal 588 31 8 1 25 10 8 6 24421 102 588 20 17 2 24401 102 588 38 1 1 50 10 8 6 24635 102 588 17 14 62 24710 102 588 28 24 08 24038 102 588 50 8 2 0 30 25 8 24905 102 588 50 43 24039 102 588 Metal Seat Linear 648 S41600 31 8 1 25 20 17 2 24424 1 102 648 38 1 1 50 10 8 6 24761 2 102 648 17 14 62 24899 2 102 648 28 24 08 24760 1 102 648 50 8 2 0 30 25 8 24887 1 102 648 50 43 24762 1 102 648 Metal S...

Страница 10: ...RIAL 6 Spring ASTM A313 S30200 14 Packing Set PTFE carbon filled PTFE 16 Washer ASTM A240 S31600 20 Spacer J 2000 filled Polytetrafluoroethylene Figure 4 Molded Graphite Flexible Graphite Packing Kit P N 24492T001 E1241 Table 5 Molded Graphite Flexible Graphite Packing Kit P N 24492T001 KEY NO DESCRIPTION MATERIAL 13 Bushing qty 2 Carbon Graphite 14A Packing Rings qty 3 Graphite 14B Packing Ring G...

Страница 11: ...H BAUMANN 32 ACTUATOR AND FISHER 3660 3661 POSITIONER BAUMANN 54 WITH FIELDVUE DVC2000 DIGITAL VALVE CONTROLLER BAUMANN 70 WITH FIELDVUE DVC6010 DIGITAL VALVE CONTROLLER BAUMANN 32 ATO FAIL CLOSED ACTUATOR WITH HANDWHEEL BAUMANN 32 ATC FAIL OPEN ACTUATOR WITH HANDWHEEL BAUMANN 54 ATC FAIL OPEN ACTUATOR WITH HANDWHEEL 163 6 4 MAX 160 46 3 BAUMANN 54 ATO FAIL CLOSED ACTUATOR WITH HANDWHEEL 31 1 24 1...

Страница 12: ...ication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability All sales are governed by our terms and conditions which are available upon request We reserve the right to modify or improve ...