background image

SAFETY PRECAUTIONS

Read and understand this instruction manual 
before installing, operating or performing 
maintenance on a 121FSV pressure and vacuum 
relief valve. Follow all precautions and warnings 
noted herein when installing, operating or 
performing maintenance on this equipment.

Safety precaution definitions

CAUTION

Damage to equipment may result if this 
precaution is disregarded.

WARNING

Direct injury to personnel or damage to 
equipment that can cause injury to personnel may
result if this precaution is not followed.

NOTE

This manual is issued for guidance only and does not 
affect our standard terms and conditions and our 
product limited warranty, all of which are available 
upon request.

Read Anderson Greenwood Marvac general instructions before continuing

ANDERSON GREENWOOD 

MARVAC FIGURE 121FSV PRESSURE AND VACUUM RELIEF VALVES

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Emerson.com/FinalControl

© 2017 Emerson. All rights reserved.

VCIOM-04095-EN 18/01

1 INSTALLATION 

121FSV pressure and vacuum relief valves 
must be mated with the appropriate flange.
1.  These valves must be gasketed and bolted 

to a flat machined horizontal flange. Bolts 
must be tightened uniformly to ensure a 
good seal.

2.  The exhaust pipework which is to be 

gasketed and bolted to the horizontal flange 
must not be supported by the valve, i.e. 
these valves are not designed to carry any 
external loads.

3.  This valve does not contain any internal 

packing. Therefore, internal checks should 
not be necessary.

4.  It is recommended that carbon steel valves 

be given a coat of paint immediately after 
installation is complete. Apply paint to 
external surfaces only.

2 MAINTENANCE (DURING ATMOSPHERIC 
VENTING PERIOD)

WARNING

The relief valve must be isolated from tank 
pressure before servicing. All gas must be 
blocked and pressure vented safely.
Wear appropriate gloves and/or breathing 
apparatus if hazardous vapors are present.

Pressure relief  (refer to Figure 1)

1.  Remove pressure cover (item 15), inspect 

O-ring for damage and replace if necessary.

2.  Remove pallet assembly to inspect pallet 

seating for wear and replace if necessary.

3.  To replace damaged/worn items from pallet 

assembly (see recommended spares):

  a.  remove nut from pallet stem, remove 

support disc, diaphragm & backing disc

  b. clean pallet surface and threads
  c. replace with new parts
  d. reassemble in reverse order
4.  Inspect valve seats (item 3) for wear and 

regrind or replace where necessary.

5.  Clean seating surface thoroughly with 

suitable solvent.

6.  Generally clean inside of valve, remove all 

foreign matter and repaint exterior where 
possible to prevent corrosion.

7.  Replace pressure pallet on pressure seat 

(with lead disc if fitted).

8.  Replace pressure cover & replace sealing 

washers if necessary, secure with screws.