66
Reference Manual
00809-0100-4308, Rev BA
Section 5: Operation
December 2014
Operation
5.3
View measurement values
Measurement values can be viewed using AMS Wireless Configurator and Field Communicator.
5.3.1
View current measurement values
Current measurement data of the Primary Variable (PV) and Secondary Variable (SV) are
presented on the
Overview
screen. To view all current measurement values, do the following:
1.
From the
Home
Screen, go to
Service Tools > Variables
.
2.
Select the desired group of measurement values to view.
To view gauges for the Primary Variable (PV), Secondary Variable (SV), Third
Variable (TV) and Fourth variable (QV), click
Mapped Variables
.
To view process values such as Level, Distance, Percent of Range, click
Process
.
To view device values such as Electronics Temperature, Supply Voltage, click
Device
.
To view Signal Quality, click
Signal Quality
.
5.3.2
View trends
1.
From the
Home
Screen, go to
Service Tools > Trends
.
2.
Select to log measurement values either in a graph or a table.
To log Level and Interface Level values in a graph, click
Level
.
To log Distance values in a graph, click
Distance
.
To log Total Volume in a graph, click
Volume
.
To log Signal Quality in a graph, click
Signal Quality
.
To log the trend of 12 data points shown in a table, click
Data History
, and then click
View Data History
. See
“Configure Data History” on page 166
for information on
how to configure device variable for recording and time between samples.
Note
Values are logged in the trend graphs only as long as the
Trends
item is selected.
5.3.3
Interpret measurement status bars
A “Good” or “Bad” status next to a value is an indication of the reliability or integrity of the data
being received, not an indication of whether or not the value is within the configured upper or
lower ranges. A value that triggers an alert, such as a high or low temperature indication, will
change the overall status of the device, but the measurement might still be indicated as “Good”
if the reliability of the data is good.
Figure 5-2. Measurement Status Bars
Содержание 3308A Rosemount 3308 Series
Страница 2: ......
Страница 6: ...vi Reference Manual 00809 0100 4308 Rev BA Title Page December 2014 ...
Страница 12: ...vi Reference Manual 00809 0100 4308 Rev BA Table of Contents December 2014 Table of Contents ...
Страница 14: ...2 Reference Manual 00809 0100 4308 Rev BA Section 1 Introduction December 2014 Introduction ...
Страница 24: ...12 Reference Manual 00809 0100 4308 Rev BA Section 2 Transmitter Overview December 2014 Transmitter Overview ...
Страница 52: ...40 Reference Manual 00809 0100 4308 Rev BA Section 3 Installation December 2014 Installation ...
Страница 72: ...60 Reference Manual 00809 0100 4308 Rev BA Section 4 Configuration December 2014 Configuration ...
Страница 80: ...68 Reference Manual 00809 0100 4308 Rev BA Section 5 Operation December 2014 Operation ...
Страница 150: ...138 Reference Manual 00809 0100 4308 Rev BA Appendix A Reference Data December 2014 Reference Data ...
Страница 162: ...150 Reference Manual 00809 0100 4308 Rev BA Appendix B Product Certifications December 2014 Product Certifications ...
Страница 196: ...4 Reference Manual 00809 0100 4308 Rev BA Index December 2014 Index ...
Страница 197: ......