Issue Number: 1
Figure 7-3 Elevator mechanical data
7.5 Creep to floor profile
The default operating mode for the
E300 Advanced Elevator
drive is Closed loop Servo for permanent magnet synchronous servo motors in gearless
Elevator systems with Creep to floor positioning. Positioning with Creep to floor is a commonly used operating mode.
For all sections of the profile shown below, there are independent parameters available for the Start optimization, Jerks, Acceleration, Deceleration
and Creep to floor which allow the ride comfort of the Elevator to be optimized.
For Creep to floor operation, the operating speed is selected according to the Elevator landing distance. The
E300 Advanced Elevator
drive by default
uses digital pre set speed selections set-up in
V1 Creep Speed Reference
(
G01
) to
V4 Speed Reference
(
G04
) as detailed below.
The Creep speed is configured to be
V1 Creep Speed Reference
(
G01
) the remaining speed selections
V2
,
V3
and
V4
can be configured for any
speed e.g Nominal speed, High speed, Low speed.
In addition to controlling the profile, the deceleration distance is also calculated in mm dependent upon the speed selected speed selected shown in
Reference Parameter Selected
(
J09
)) and the profile settings. The calculated deceleration distance is displayed in
Deceleration Distance Calculated
(
J43
) for the activated speed.
The measured deceleration distance is displayed after every travel in
Deceleration Distance Measured
(
J44
) in mm. The measured Creep speed
distance is also available and shown in
Creep Distance Measured
(
J45
)
.
The real-time demand on the Elevator control system is low with Creep to floor positioning with a typical cycle time of the Elevator controller of 5 to 20
ms and the
E300 Advanced Elevator
drive of 8 ms the minimal positioning distance with Creep to floor is calculated as follows:
The maximum Creep speed distance =
Positioning distance [mm]
≥
V
Nominal
[m/s] x 30 ms
The stop accuracy =
Accuracy [mm]
≤
V
Creep speed
[m/s] x 30 ms
The time required for the Creep speed =
Time Creep speed [ms] = positioning distance [mm] / V
Creep speed
[m/s]
Table 7-11 Elevator speeds and distances
The timing diagram in Figure 7-4
Creep to floor profile, Timing diagram
on page 160, shows the sequence of operation in the Creep to floor mode as
is also detailed below:
•
A start sequence is received at the drive from the Elevator controller by means of selecting both a speed and direction.
•
Following selection of both the speed and direction inputs on the drive, the Elevator controller then closes the output motor contactors. On closing
the output motor contactors, the Safe Torque Off (STO) Drive enable is applied to the drive, and if the Fast disable is used this is also removed
and the drive’s output becomes active.
•
Once enabled, the symmetrical drive current limit is ramped up and torque is generated to hold the motor at zero speed, also using the Start lock
position if active.
•
With the drive holding the motor at zero speed the brake is opened and the profile started.
Following any system fault where a drive trip may occur, and the brake control is carried out by the drive, the brake is automatically closed and the
drive output disabled.
Speed selected
Speed selected parameter
V1
Speed Reference
(creep speed by default)
G01
V2
Speed Reference
G02
V3
Speed Reference
G03
V4
Speed Reference
G04
Elevator
motor
Elevator
gearbox
Elevator
sheave
Elevator
roping
A
Nominal elevator
speed (motor) rpm
B
Nominal elevator
speed mm/s
C
Sheave
diameter
D
Roping
E
Gear ratio
numerator
F
Gear ratio
denominator
NOTE