Electric Installation.

Installation and user instructions for  

Eye

 and 

Media

 cable managed desks

BS6396: 2008 Electrical Systems in Office 
Furniture & Educational Furniture

Electrical equipment and installations must be designed and 
tested to ensure their safety and to comply with statutory 
regulations, in particular the “Electricity at Work Regulations”. 
Relevant British Standards may be used as a means of 
demonstrating safety and compliance with the regulations.  
In the case of electrical systems in office furniture and educational 
furniture, the relevant standard for systems connected to the 
mains supply by means of a 13A plug is BS 6396:2008.

A. Media/Eye Trunking
B. No. 8 x ½” Woodscrew
C. Trunking End Cap
D. M4 Taptite Screw
E. Serrated Washer
F. Media Leg Riser
G. Leg Riser Cover

Sockets installed in office furniture are 
intended to supply office equipment with 
a rating not exceeding 5A with BS 6396 
referring to all office furniture electrical 
installations when completed must be tested. 
Section 7 of BS 6396 sets out the procedures. 
These tests should also be carried out on 
reconfigured desks and screens as well 
as new installations. Periodic inspections 
and tests must be carried out to fulfil the 
requirements of BS 6396 and the “Electricity 
at Work Regulations” in maintaining a safe 
working environment.

Sockets installed in office furniture are 
intended to supply office equipment with  
a rating not exceeding 5A.

The diagrams on the left indicate the 
maximum number of socket outlets that may 
be connected from a single power supply 
cable fed from a 13 Amp BS 1363 plug and 
their relevant fuse ratings.

DIAGRAM B

20mm Ceramic Fuses

DIAGRAM A

Electrical items required

B

D

E

C

A

B

D

E

B

F

D

G

6 Outlets

4 Outlets

2 Outlets

5A F

use

5A F

use

3.15A F

use

3.15A F

use

3.15A F

use

13A  Plug Fuse

Unfused