background image

EMERALD PLANET HEAD OFFICE - SYDNEY

 Unit 2 / 29 Mitchell Road, Brookvale NSW 2100 Australia 

P

 02 9466 6000

SMOKE ALARM  

USER MANUAL   

POWER:   

DC2*1.5V Alkaline AA battery 

OPERATION CURRENT: 

 

<4uA (standby), <40mA (alarm)

 

ALARM VOLUME:   

>85dB(A) at 3 meters

 

SMOKE SENSITIVITY: 

 

0.09-0.140dB/m 

HEAT SENSITIVITY:

 

54-70

o

C

LOCAL SMOKE ALARM 

 

ISO8201 BI 0.5s - pause 0.5s – BI 0.5s – pause 0.5s – BI

 

SOUND PATTERN:

 

0.5s – pause 1.5s, with the red LED flash, repeat this  

 

alarm pattern.

LOCAL HEAT ALARM 

 

BI 0.2s - pause 0.1s, with the red LED flash,

 

SOUND PATTERN: 

 

repeat this alarm pattern.

WIRELESS ALARM 

 

Bi - Bi - pause 1.2s, with the red LED flash,

 

SOUND PATTERN: 

 

repeat this alarm pattern.

DESCRIPTION

This unit uses a photoelectric smoke detection 
chamber. Photoelectric technology is more 
sensitive to detecting slow smoldering fires which 
generate thick, black smoke, a little heat and may 
smolder for hours before bursting into flames. 
Unlike previous ionizing alarms, this smoke alarm 
does not contain radioactive material and is 
harmless to the environment.
Emerald Planet recommends that smoke alarms 
be installed in every room (except bathrooms 
and kitchens), and every other area of the home, 
making sure all people in the home will be able to 
hear and respond to the alarm when activated.
Each state of Australia has its own legislation 
regarding smoke alarm requirements. Please refer 
to the following websites to check your states 
current installation requirements.

NSW

fire.nsw.gov.au/page.php?id=80

QLD

www.qfes.qld.gov.au/community-safety/smokealarms 

SA 

mfs.sa.gov.au/site/community_safety/home_fire_and_life_
safety_information_sheets_domestic/smoke_alarms_what_
you_need_to_know.jsp

WA

dfes.wa.gov.au/safetyinformation/fire/fireinthehome/
FireintheHomeManualsGuidelines/DFES_FireintheHome-
SmokeAlarm-Legislative-Requirements-LAWS.pdf 

TAS

tfseducation.com.au/resources/publications 

ACT 

esa.act.gov.au/community-information/home-fire-safety/
smoke-alarms/ 

NT

https://nt.gov.au/emergency/community-safety/  
fire-safety-at-home/smoke-alarms 

MODEL NUMBER: EP-RF-R1

Thank you for choosing this smoke alarm wireless 
interconnectivity and heat detection. Please take a 
few minutes to read the user’s manual thoroughly 
and familiarise yourself and your family with its 
operation, and save it for future reference.

This unit has been designed to meet the latest 
safety standards demanded in Australia and 
complies with the requirements of AS3786:2014.