MOTOR DRIVEN PLUNGER METERING PUMP

OPERA

TING MANU

AL

EN

PRIUS P

 

SS PUMP HEAD

PP PUMP HEAD

Содержание PRIUS P

Страница 1: ...MOTOR DRIVEN PLUNGER METERING PUMP OPERATING MANUAL EN PRIUS P SS PUMP HEAD PP PUMP HEAD...

Страница 2: ...ERRORS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Version R1 03 17 NORME CE EC RULES STANDARD EC NORMAS DE LA CE Direttiva Bassa Tensione Low Voltage Directive Directiva de baja tensi n Dire...

Страница 3: ...3 2 Connection diagrams 16 4 START UP18 4 1 Start up 18 5 PRIMING 19 5 1 How to prime the pump 19 6 MAINTENANCE 20 6 1 Maintenance schedule 20 6 2 Maintenance inspection 20 6 3 Shutdown 21 7 TROUBLESH...

Страница 4: ...ND DISCHARGE You must take all necessary measures to avoid this condition When installing always observe national regulations Manufacturer is not liable for any unauthorized use or misuse of this prod...

Страница 5: ...ivery valves on the pump head PRIUS is a constant dosing pump Flow rate is determined by the stroke length The stroke length is adjustable from 0 to 100 using the stroke length adjustment knob 1 DESCR...

Страница 6: ...8 l h 10 bar 010043 43 l h 10 bar 010019 126 l h 10 bar 010032 32 l h 10 bar 010126 126 l h 10 bar 010016 16 l h 10 bar 010063 63 l h 10 bar 010130 130 l h 10 bar 010031 31 l h 10 bar 010070 70 l h 10...

Страница 7: ...7 Fig 1 PRIUS P pump Stroke lenght knob Oil sight glass Oil cap inlet Power supply Suction vale Delivery valve Oil outlet...

Страница 8: ...vel 2 Audible noise 78 dbA 5 dB Protection degree IP 55 Max suction height 3 m Oil capacity 0 3 lt Refer to Lubricant type table Dosing accuracy 5 at rated pressure The specified temperature can be ex...

Страница 9: ...9 1 3 1 PLUNGER Prius P plunger pumps Material ceramic SIALOX96 or Stainless Steel AISI420 Lenghts available 14 25 32 40 50...

Страница 10: ...0 18 kW G1 2 12x18 A 010013 94 13 010010 70 10 010005 35 5 25 010080 175 10 80 0 18 kW G1 2 12x18 A 010043 94 43 010032 70 32 010016 35 16 32 010130 175 10 130 0 18 kW G1 2 12x18 A 010070 94 70 010052...

Страница 11: ...010010 70 10 010005 35 5 25 010080 175 10 80 0 18 kW R1 2 010043 94 43 010032 70 32 010016 35 16 32 010130 175 10 130 0 18 kW R1 2 010070 94 70 010052 70 52 010026 35 26 40 010210 175 10 210 0 37 kW...

Страница 12: ...7 63 010031 44 31 40 010195 175 10 195 0 37 kW G3 4 d i 18 mm B 010097 87 97 010048 44 48 50 010300 175 10 300 0 37 kW G3 4 d i 18 mm B 010150 87 150 010075 44 75 PRIUS P 60 Hz stroke length PLUNGER d...

Страница 13: ...if necessary POWER SUPPLY DISCONNECTION Always disconnect power to the motor before you perform any installation or maintenance tasks Failure to disconnect power will result in serious physical injury...

Страница 14: ...hipping Fill the oil reservoir through oil inlet Fig 2 Oil filling The required amount of oil is 0 30 lt For acceptable lubricants see the table below Check oil level regularly Change the oil every 8...

Страница 15: ...movements that could damage near objects Never operate any pumping system with a blocked suction and discharge Operation even for a brief period under these conditions can cause motor to overheat You...

Страница 16: ...2 2 6 Installation drawings I WKH LQMHFWLRQ YDOYH RI WKH 3ULXV LV DVVHPEOHG RU XVHG LQ OLQH GR QRW DSSO WKH RULQJ WR SUHYHQW LW IURP UXQQLQJ LQWR WKH V VWHP QVWDOO R ULQJ RQO ZKHQ ILWWLQJ LQ WR D V V...

Страница 17: ...be connected to a motor protection switch Residual Current Circuit Breaker MCCB 4 Verify the cable Cable type and cross section must be in accordance to motor data 5 Verify the motor rotation Start up...

Страница 18: ...18 L1 L1 N N U1 U1 V1 V1 W1 W1 W2 W2 U2 U2 V2 V2 CONNECTION DIAGRAMS for 1 PHASE MOTOR MOTOR SUITABLE FOR INSERTIONS WITH RANGE OF AT LEAST 6 INTERVAL...

Страница 19: ...nimum pressure 2 Turn the stroke lenght knob on 20 3 After 5 minutes gradually increase the capacity until reaching the prescribed value for the operating condition Control the pressure correspond to...

Страница 20: ...f noflow as these conditions may introduce the potential for chemical overdosing Not doing so may result in elevated chemical concentrations and hazerdous gas intro duction into the pool or spa Never...

Страница 21: ...are tight Check the mechanical seal if the pump has been left idle Annual inspections Perform these inspections one time each year 6 1 Maintenance schedule Before start maitenance the operator must b...

Страница 22: ...procedure SHOULD BE CARRIED OUT BY AUTHORIZED AND QUALIFIED PERSONNEL OPERATOR PROTECTION Use safety equipment according to the company regulations Use this safety equipment within the work area duri...

Страница 23: ...ery pipe obstructed or blocked Clean delivery pipe Low level oil Refill oil Liquid loss Plunger o ring damaged Contact manufacturer for replacement If the problem can not be solved please contact afte...

Страница 24: ...on FPM O ring Ethylene propylene EPDM O ring Nitrile NBR O ring Product Formula Ceram PVDF PP PVC SS 316 PMMA Hastel PTFE FPM EPDM NBR PE Acetic Acid Max 75 CH3COOH 2 1 1 1 1 3 1 1 3 1 3 1 Hydrochlori...

Страница 25: ...1 2 3 4 5 6 A B C D Progettato da Controllato da Data Toll Gen Peso Lordo Peso Netto 400 00 380 00 187 00 157 00 303 00 9 DIMENSIONS...

Страница 26: ......

Страница 27: ...erating controls keyboard display etc Elettronics Other LEAKS Connections Pump head NOT OR INADEQUATE FUNCTION OTHER OPERATING CONDITIONS Location installation description Chemical Start up date Runni...

Страница 28: ...on center for the recycling of electronic and electrical equipment For more information visit the online site When dismantling a pump please separate material types and send them according to local re...