278
EMC Symmetrix DMX-3 Product Guide
Power Sequences
Vaulting
Vaulting allows the Symmetrix system to preserve the contents of
cache during a powerdown procedure. When a DMX-3 system is
powered down, transitioned to offline, or environmental conditions
trigger a vault situation, a vaulting procedure is initiated. This
procedure writes all information in cache above a certain point or
vault line to the first hypers of designated drives. These are called
vault drives. When a system is brought back online, the vault hypers
write the stored information back into global memory.
A vault save is initiated under the following circumstances:
◆
System VTOC
◆
When the system is taken offline (DAs taken offline)
◆
Power loss
◆
Whenever the environment monitor determines:
• A loss of vault drives that indicate a “Need to Vault”
• A loss of battery holdup time will indicate a "Need to Vault"
• A loss of BBU battery holdup time will prevent the system
from powering up due to a lack of battery power to complete
the vault (minimum 300 sec needed)
Содержание Symmetrix DMX-3
Страница 14: ...EMC Symmetrix DMX 3 Product Guide 14 Figures...
Страница 20: ...20 EMC Symmetrix DMX 3 Product Guide Warnings and Cautions...
Страница 44: ...44 EMC Symmetrix DMX 3 Product Guide Introducing the Symmetrix DMX 3...
Страница 100: ...100 EMC Symmetrix DMX 3 Product Guide Symmetrix DMX 3 Hardware...
Страница 114: ...114 EMC Symmetrix DMX 3 Product Guide Symmetrix DMX 3 Input Output Operations...
Страница 224: ...224 EMC Symmetrix DMX 3 Product Guide Data Integrity Availability and Protection...
Страница 254: ...254 EMC Symmetrix DMX 3 Product Guide Mainframe Features and Support...
Страница 282: ...282 EMC Symmetrix DMX 3 Product Guide Power Sequences...