
E
perf
E-73
Command Line Interface
total value of the summed set counter is incremented. The items that
make up the summed sets are:
◆
Physical Link Errors Summed Set
• Link Failures
• Sync Losses
• Signal Losses
• Protocol Errors
• Invalid Tx Words
• CRC Errors
• Frames Too Short
• Delimiter Errors
◆
Link Sequence Counts Summed Set
• Link Resets Received
• Link Reset Sent
• OLS Received
• OLS Sent
◆
Logical Link Errors Summed Set
• Discarded Frames
• Address ID Errors
• Class 2 Busied Frames
• Class 2 Rejected Frames
• Class 3 Discarded Frames
perf.thresholdAlerts.counter.addAlert
Syntax
addAlert name
Purpose
This command configures a new counter threshold alert and assigns
it a name. The new alert is assigned default settings which can then
be changed using the other counter threshold alert commands.
The default settings for a new counter threshold alert are:
◆
Ports: None
◆
Counter: None
◆
Increment: 100
◆
Interval: 60 minutes
◆
State: Disabled
Содержание Connectrix ED-64M
Страница 4: ...Connectrix ED 64M User Guide iv...
Страница 18: ...xviii Connectrix ED 64M User Guide Figures...
Страница 26: ...xxvi Connectrix ED 64M User Guide Preface...
Страница 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Страница 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Страница 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Страница 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Страница 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Страница 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Страница 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...
Страница 476: ...Connectrix ED 64M User Guide i 8 Index...