![EMC Connectrix ED-64M Скачать руководство пользователя страница 253](http://html1.mh-extra.com/html/emc/connectrix-ed-64m/connectrix-ed-64m_user-manual_2399809253.webp)
A
Fabric Element MIB Support
A-37
Using SNMP to Manage the Switch
FxPort Operation
Table
A table that contains, one entry for each FxPort in the Fabric Element,
operational status and parameters of the FxPorts.
Table A-21
FxPort Operation Table
Fabric Element MIB
Object Name
Type
Provided
By
Access Description
fcFxPortOperFxPortIndex
FcFeFxPortIndex
SNMP
R
This object identifies the FxPort within the module. This
number ranges from 1 to the value of
fcFeModulePortCapacity for the associated module.
The value remains constant for the identified FxPort
until the module is re-initialized.
This number ranges from 1 to
AS_glob.prod_cnfg_ptr->ports_per_module.
FcFxPortID
FcAddressId
Login
Server
R
The address identifier by which this FxPort is identified
within the Fabric. The FxPort may assign its address
identifier to its attached NxPort(s) during Fabric Login.
Return a port id if the port is login into the fabric,
otherwise this address is 000000 in FCEOS.
fcFPortAttachedPortName
FcPortName
Login
Server
R
The port name of the attached N_Port, if applicable. If
the value of this object is ‘0000000000000000’H, this
F_Port has no NxPort attached to it. This variable has
been deprecated and may be implemented for
backward compatibility. Not supported for NL ports.
FcFPortConnectedPort
FcAddressId
SNMP
R
The address identifier of the destination FxPort with
which this FxPort is currently engaged in a either a
Class 1 or loop connection. If the value of this object is
‘000000’H, this FxPort is not engaged in a class 1
connection. This variable has been deprecated and
may be implemented for backward compatibility.
This address is fixed at 0x000000.
FcFxPortBbCreditAvailable
Gauge
PSCC
R
The number of buffers currently available for receiving
frames from the attached port in the buffer-to-buffer
flow control. The value should be less than or equal to
fcFxPortBbCredit.
FcFxPortOperMode
FcFxPortMode
AS
R
The current operational mode of the FxPort.
This value is fport(2) if the port_state_data is
unavailable or the port is a fport, or unknown(1) for the
other port state.
FcFxPortAdminMode
FcFxPortMode
AS
R
The desired operational mode of the FxPort.
This value is fport(2) if the port_state_data is
unavailable or the port is a fport, or unknown(1) for the
other port state.
Содержание Connectrix ED-64M
Страница 4: ...Connectrix ED 64M User Guide iv...
Страница 18: ...xviii Connectrix ED 64M User Guide Figures...
Страница 26: ...xxvi Connectrix ED 64M User Guide Preface...
Страница 30: ...xxx Connectrix ED 64M User Guide Warnings and Cautions...
Страница 60: ...2 2 10 Connectrix ED 64M User Guide Operating the Director...
Страница 86: ...3 3 26 Connectrix ED 64M User Guide Product Manager Overview...
Страница 326: ...B B 8 Connectrix ED 64M User Guide Configuring Network Addresses...
Страница 334: ...D D 6 Connectrix ED 64M User Guide Configuring Embedded Web Server Passwords...
Страница 442: ...F F 4 Connectrix ED 64M User Guide Specifications...
Страница 450: ...G G 8 Connectrix ED 64M User Guide Customer Support...
Страница 476: ...Connectrix ED 64M User Guide i 8 Index...