nas_fs
173
The nas Commands
CAUTION
!
The enterprise version of file-level retention is intended for
self-regulated archiving. The administrator is considered a
trusted user and the file-level retention capability does not
protect the archived data from the administrator’s actions. If
the administrator attempts to delete the file system, the file
system issues a warning message and prompts the
administrator to confirm the operation. This version of
file-level retention is not intended for high-end compliance
applications such as pharmaceuticals, aerospace, or finance.
[-option <options>]
Specifies the following comma-separated option(s):
nbpi=
<number>
The number of bytes per inode block. The default is 8192 bytes.
mover=
<movername>
Assigns an optional Data Mover to build a file system. If no Data
Mover is assigned, the system will automatically pick the first
available Data Mover to build the file system.
slice=
{y|n}
Specifies whether the disk volumes used by the new file system
may be shared with other file systems using a slice. The slice=y
option allows the file system to share disk volumes with other file
systems. The slice=n option ensures that the new file system has
exclusive access to the disk volumes it uses, and is relevant when
using TimeFinder/FS.
When the symm_std, symm_std_rdf_src, symm_ata, and
symm_ata_rdf_src
pools are specified, the default is not to slice
the volumes, which is overridden with slice=y.
When the clar_r1, clar_r5_performance, clar_r5_economy,
clarata_r3
, clarata_archive, cm_r1, cm_r5_performance,
cm_r5_economy
, cmata_r3, and cmata_archive pools are
specified, the default is to slice the volumes, which is overridden
with slice=n. Refer to to change the default slice option.
[-name <name>] [-type <type>] -create
{size=<integer>[T|G|M] |samesize=<fs_name>[:cel=<cel_name>]}
pool=
<pool>
Creates a file system on the volume specified by its desired size and
storage pool or by using the same size as a specified local or remote
Содержание Celerra
Страница 6: ...Celerra Network Server Command Reference Manual 6 Contents...
Страница 10: ...10 Celerra Network Server Command Reference Manual Preface...
Страница 16: ...16 Celerra Network Server Command Reference Manual Overview...
Страница 276: ...276 Celerra Network Server Command Reference Manual The nas Commands...
Страница 347: ...server_devconfig 347 The server Commands server_4 chain 0 chain 16 done server_5 server_5 chain 0 chain 16 done...