    Install Rails and Components in Rack 

Setting Up the EMC

®

 Celerra

®

 NS40 System

Before You Begin

  

1

1

 

2a Install Blade Enclosure

300-004-901 Rev A01

Copyright © 2007 EMC Corporation. All rights reserved.

 

2c Install Control Station

 

2b Install Storage Processor Enclosure

LAN1 

LAN2 

Front 

CIP-000935

Disk-array enclosure

Standby power supply

Control Station

Storage processor

enclosure

Blade enclosure

Shipping Rack

 

Before you begin: 

 •  The NS40 system you are about to install comes factory pre-loaded with Celerra Network Server software (DART) and 

 

     Storage Array software (FLARE). 

DO NOT PERFORM A FRESH INSTALL OF SOFTWARE

. If a software upgrade (not fresh install)

 

     is required, perform it after installation. For more information refer to Solution Case emc163262. 
 •  Go to the Celerra Tools page for the latest information on the NS40 product: (http://Powerlink.EMC.com and select 

 

     

Celerra Tools

 in the 

Navigator

).

 •  

Two people are required to lift several hardware components.

 

When installing the disk-array enclosures in the cabinet, do not remove the disks.

 

 •  Remove

 only

 the 16 visible Phillips-head screws on the front of the mini-rack. Do not remove any of the other screws or you may

 

     injure yourself   or damage the equipment.

Alignment 
pin 

Rear 

Front 

Adjustable rail 

Alignment 
pin 

Right rear 

Mounting rail 

Screw (2) 

Alignment  
pin 

CIP-000921

Right front 

Screw

Mounting 
rail 

Rear 

Front 

Enclosure

CIP-000922

Rear 

Front 

Enclosure

CIP-000923

Rail
catch

Screw
(2 per side)

Bezel 

Indentation 
to center of 
the rack 

  

2

  

4

1. Select 7U (12.25 in.) of available rack space for the NS40, plus 3U (5.25 in.) for each optional disk-array enclosure 

 

    (1U =1.75 inches).

 

 

   NOTE

: Use the supplied clip nuts if required for your rack.

 

2. 

Starting at the bottom of the selected rack space,

 mount one set of 1U rails for the blade enclosure as follows:

a. From the cabinet front, insert the rail alignment pin into the middle hole of the 1U space on the right side at the the 

 

    rear of the cabinet. Orient the rails so the sliding insert faces the inside of the rack.

 

b. Extend the rail to the front of cabinet, aligning the rail holes with the channel holes (the verticle metal bar with 

    evenly spaced holes) on the inside of the cabinet. 

Always 

ensure the rail is level

c. Install 

but do not tighten

 one of the provided screws in the top hole on the front of the rail through the cabinet channel.

 

d. From the cabinet rear, insert 

but do not tighten

 two screws in the top and bottom holes on the rail back through the 

 

    cabinet channel.

 

e. Repeat steps b-e to install the left rail.

3. 

Two people are required for this installation:

 From the cabinet front, align the blade enclosure with the mounting channels. 

With the help  

    of another person

, slowly slide the blade enclosure into the rails until the front assembly flanges are flush with the cabinet channels.

 

4. 

Do not insert any new screws

, but tighten the screws on each end securing the mounting rails to the cabinet channels. 

 

5. Insert two of the provided screws into the middle and bottom holes of each rail catch. Attach the bezel rail catches to the holes 

 

    in the rail flanges on the front of the cabinet. Then press the bezel onto the rail catches until it snaps into place.

1. In the 1U space above the blade enclosure, install the storage processor 

 

       enclosure as described in 

Step 2a Install Blade Enclosure.

   

NOTE: Do not remove the Control Station label at this time.

 

 

1. In the 1U space above the storage processor enclosure, 

 

    install the Control Station as described in 

Step 2a Install Blade Enclosure

.

  

2

  

3

 

 Required parts:

 

 •  Blade enclosure number for the  NS40 single blade P/N 100-520-326 or 100-520-328 

 

                                                                 or dual blade P/N 100-520-327 or 100-520-329 

 

  •  Adjustable rail kit P/N 100-561-802

 

  •  Bezel

 

 

Required parts:

 

 • Storage processor enclosure for the NS40 P/N 100-520-372

     

 • Rail kit P/N 100-561-802

 

  

Required parts:

 

 • Control Station P/N 100-520-606 

 

 • Rail kit P/N 100-520-527 

 

 • Adjustable Rail Installation kit

B

A

Blade 3 (B 3)

Blade enclosure

SP A

B 2

CIP-000914

SP B

Storage processor

enclosure

B

A

Blade 3 (B 3)

Blade enclosure

SP A

B 2

CIP-000915

SP B

Control Station

Storage processor

enclosure

 

Required tools:

 

•  Flathead screwdriver

 

•  Manual Phillips-head screwdriver 

 

 

Avoid stripping the screw-heads.