22
5.52 ELECTRICAL CONTROLS: HUF12000E
IMPORTANT
A circuit breaker that trips
repeatedly may indicate a
problem.
HUF12000E
A
B
C
D
E
F
G
H
A. Voltmeter meter monitors and displays the volt-
age being produced by the generator. The top
scale displays the 120 Volt range and the bot-
tom, the 240 Volt.
B. These two outlets (5-15R) are used to provide
120 Volt, 20 Amp power.
C. This outlet (L5-30) is used to provide 120 Volt,
30 Amp power.
D. This outlet (L14-30) is used to provide 120/240
Volt, 30 Amp power .
E. These outlets (6-50R & 14-50R) are used to
provide 120/240 Volt, 50 Amp power.
F. These 20 Amp breakers are used to protect the
20 Amp 120 Volt outlets (B). Push the switch
to reset.
G. This 30 Amp circuit breaker protects the two 30
Amp out lets. (C&D). Move the switch up to engage
the breaker and down to disengage.
H. Main Switch / 50 Amp breaker is the master
overload for the generator. Move the switch up
to engage the breaker and down to disengage
the breaker.