background image

5

HP01P006SS man v.170807

Silent Air Series

Basic Guidelines

1.  Allow only trained, authorized persons who 

have read and understood these operating 

instructions to use this compressor. Failure 

to follow the instructions, procedures and 

safety precautions in this manual can result in 

accidents and injuries.

2.  NEVER start or operate the compressor 

under unsafe conditions. Tag the compressor, 

disconnect and lock out all power to it to 

prevent accidental start-up until the condition 

is corrected.

3.  Install, use and operate the compressor only 

in full compliance with all pertinent OSHA 

regulations and all applicable Federal, State & 

Local Codes, standards and regulations.

4.  NEVER modify the compressor and/or 

controls in any way.

5. 

Keep a first aid kit in a convenient place. Seek 

medical assistance promptly in case of injury. 

Avoid infection by caring for any small cuts 

and burns promptly.

Breathable Air

1.  NEVER use air from this compressor for 

breathable air except in full compliance with 

OSHA Standards 29 CFR 1910 and any other 

Federal, State or Local codes or regulations.

Death or serious injury can result 

from inhaling compressed air 

without using proper safety 

equipment. See OSHA standards 

on safety equipment. 

2.  DO NOT use air line anti-icer systems 

in air lines supplying respirators or other 

equipment used to produce breathable air. 

DO NOT discharge air from these systems in 

unventilated or other confined areas.

Pressurized Components

1.  This equipment is supplied with a ASME 

designed pressure vessel protected by an 

ASME rated relief valve. Pull the ring before 

each use to make sure the valve is functional. 

DO NOT attempt to open valve while the 

machine is under pressure.

2.  Improper maintenance could lead to the air 

tank bursting or exploding.
3.  Drain air tank after each use or 

daily to prevent moisture buildup in the 

air tank. Rust can weaken the air tank 

and cause leaks or bursting. If rust is 

detected, replace tank immediately. 

4.  Do not attempt repairs to the air tank by 

welding, drilling or other modifications. Such 

modifications may weaken the air tank and 

cause a hazardous condition.

 

5.  If the air tank develops a leak, replace it 

immediately. Never repair, weld or make 

modifications to the air tank or its attachments.

6.  Do not make adjustments to the factory-set 

pressures.

7.  Never exceed attachments' manufacturer's 

maximum-allowable pressure rating.

8.  Do not use plastic pipe or lead tin solder 

joints for a discharge line as the may not 

withstand the high heat developed during air 

compression.

Personal Protective Equipment

Be sure all operators and others around the

compressor and its controls comply with all 

applicable OSHA, Federal, State and local 

regulations, codes and standards relating to 

personal protective equipment. This includes 

respiratory protective equipment, protection for 

the extremities, protective clothing, protective 

shields and barriers, electrical protective 

equipment, and personal hearing protective 

equipment.

1.  Eye protection should be worn at all times 

when operating this tool. Use ANSI approved 

safety glasses. Everyday eyeglasses are NOT 

safety glasses. Dust mask, non-skid safety 

shoes, hard hat, or hearing protection should 

be used in appropriate conditions.

2.   Wear proper apparel.  

Loose clothing, gloves, neckties, rings, 

bracelets, or other jewelry may present a 

potential hazard when operating this tool. 

Please keep all apparel clear of the tool.

Inspection

Inspect compressor prior to any use. Check for 

external damage that might have occurred during

transit. Be careful of moving parts. Report any 

damage to delivery carrier immediately.

Do not operate unit if damaged 

during shipping, handling or use. 

Damage may result in bursting and cause injury 

or property damage.

Installation

Area

1.  Install compressor in a clean, dry and well-lit 

area. Be sure installation area can maintain a 

temperature range between 35° - 110° F (2° - 

43° C).

If ambient temperature drops 

below 32˚F (0° C), be sure to 

protect safety/relief valves and drain valves from 

freezing. NEVER operate compressor with 

temperatures below 15˚F (-9.5° C) or above 125˚F 

(52° C).

2. 

Allow sufficient space around compressor for 

maintenance access and adequate airflow. 

Mount unit leaving a minimum of 15 inches (38 

 

 

Содержание 815002013992

Страница 1: ...and manufactures products for safe operation However operators and maintenance per sons are responsible for maintaining safety All safety precautions are included to provide a guideline for minimizing the possibility of accidents and property damage while equipment is in operation Keep these instructions for reference Model UPC HP01P006SS man v 170807 HP01P006SS 815002013992 ...

Страница 2: ...ation 5 Area 5 Electrical Safety 6 Operation 6 Safety Rules 6 Air Tool Cautions 7 Power Source Connection 8 Power Requirements 8 Grounding Instructions 8 Connect to power source 8 Getting Started 8 Assembly 8 Installing the air filter 8 Operation 9 Before operating your new air compressor 9 General Overview 9 Installation and Location 9 Connecting to Power Source 9 Extension Cords 9 Attaching an a...

Страница 3: ...ters tank 3 RUBBER FOOT Reduces compressor vibration and movment 4 SAFETY VALVE The safety valve automatically relieves pressure from the air tank in the event of excessive pressure build up Safety Valve is preset at factory Do not attempt to make any adjustments to the safety valve Periodically pull the ring on the safety valve end to check that it is working properly 5 RESERVOIR AIR PRESSURE GAU...

Страница 4: ...o decrease air pressure 11 AIR COUPLER Convenient brass quick disconnect air coupler allows for fast easy connection to an air hose 12 WHEELS fig 2 5 4 6 8 10 Safety Information This manual contains very important information to know and understand This is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS To help understand this information observe the following Danger indicates an imminently ...

Страница 5: ...drilling or other modifications Such modifications may weaken the air tank and cause a hazardous condition 5 If the air tank develops a leak replace it immediately Never repair weld or make modifications to the air tank or its attachments 6 Do not make adjustments to the factory set pressures 7 Never exceed attachments manufacturer s maximum allowable pressure rating 8 Do not use plastic pipe or l...

Страница 6: ...cooling lines 9 If the tool is equipped with three pin plug it should be plugged into a three pin electrical socket Never remove the ground pin 10 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 11 To reduce the risk of electrical shock or injury do not expose tool to moisture Don t use...

Страница 7: ... NEVER touch the motor the discharge tubing or compressor pump while in operation 18 The compressor turns itself on and off automatically while the pressure switch is turned on 19 The air pressure switch is set at the factory for optimum performance of your equipment Never attempt to bypass or remove this switch as serious damage to equipment or personal injury could result from excessive air pres...

Страница 8: ...ctor cord and a 3 prong grounding plug to fit a grounded type receptacle B fig 1 Do not remove the 3rd prong grounding pin to make it fit into an old 2 hole wall socket or extension cord If an adaptor plug is fig 1 A B C used C fig 1 it must be attached to the metal screw of the receptacle The use of an adaptor plug is illegal in some areas including Canada Check your local codes If you have any d...

Страница 9: ...l on top of the compressor Connecting to Power Source This air compressor is designed to operate on a properly grounded 120 volt 60 Hz single phase alternating current AC power source with a fused 20 amp time delayed fuse or circuit breaker It is recommended that a qualified electrician verify the ACTUAL VOLTAGE at the receptacle into which the unit will be plugged and confirm that the receptacle ...

Страница 10: ...C 2 Open the air tank drain valve and release all air pressure from the air tank before attempting to start in cold weather After air is released from air tank close drain valve 3 Pull the ring on the safety valve before each use to make sure the valve is functional 4 Plug the air compressor directly into a 120 volt electrical outlet Do not use an extension cord when starting your air compressor i...

Страница 11: ...eak in safety valve 3 Check valve by pulling on ring If condition persists replace valve Safety valve releases Defective pressure switch Replace pressure switch Pressure in tank falls 1 Air leaks at joints 1 Allow the compressor to build pres sure in the tank to the max pressure if possible Spray or brush soapy water on all air connections and look for bub bles Tighten leaky connections Do not ove...

Страница 12: ...nd contact cus tomer support Compressor doesn t provide as much air as when new and or cuts off after a much shorter time period 1 Tank has reduced capacity due to water retention 2 Pressure switch is out of adjust ment 1 Open drain valve to release water 2 Contact customer support Pump unit does not stop when the tank reaches maxi mum working pressure Defective or pressure switch out of adjustmen...

Страница 13: ...Air Series Schematic Drawing 73 45 43 55 56 57 33 25 26 27 28 29 30 34 35 36 37 44 31 32 24 18 19 20 21 22 23 16 17 40 41 15 14 13 9 12 11 10 8 6 4 7 5 3 2 42 1 59 58 66 65 68 67 72 71 72 63 69 39 64 48 46 47 49 50 60 51 62 61 52 53 54 ...

Страница 14: ...als Warranty does not apply to defects due directly or indirectly to misuse abuse negligence or accidents repairs or alterations and lack of maintenance HULK shall not be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this warranty the manufacturer part must be returned for examination by...

Отзывы: