background image

FSP350-4W / FSP400-4W / FSP450-4W / FSP500-4W / FSP650-4W

1.5" VALVE REPLACEMENT PARTS

Used after backwash to flush dirt from valve

Cleaning Filter by reversing the flow

CLOSED 

Shuts off all flow to filter or pool

RINSE

BACKWASH 

FILTER 

Valve Position

Normal Filtration and Vacuuming

Function

THIS FILTER OPERATES   UNDER HIGH PRESSURE.  WHEN ANY PART OF THE CIRCULATING
SYSTEM (e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE
SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO 
BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.

WARNING

!

!

TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM, 
CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY.

!

DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING. 

!

Key No

.

Part No.

Product

 

Description

 

Qty

1

03018009

Pin

 

for

 

handle

1

2

01013036

Handle

 

for

 

1.5" 4

-

way

 

Valve

1

3

03011003

Ø

4*12

 

Self

-

drilling

 

screw

5

4

01013040

Pressing

 

Ring

1

5

01013041

Fixation

 

for

 

1.5" 4

-

way

 

Valve

 

Handle

1

6

01181003

Washer

 

for

 

1.5" 4

-

way

 

Valve

 

Handle

1

7

02011017

O-Ring

 

for

 

Rotor

2

8

89280104

Sight

 

Glass

 

with

 

O-Ring

1

9

01111048

Connector

 

for

 

Pressure

 

Gauge

/

Stopper

1

10

06021013

Plastic pressure gauge With O-Ring(40Psi)

1

11

02311005

Spider

 

Gasket

1

12

01013098

Lid

 

for

 

for

 

1.5" 4-way

 

Valve

 

Rotor

1

01021003

Rotor

 

for

 

1.5" 4-way

 

Valve

1

13

01013039

1.5" 4-way

 

Valve

 

Rotor

 

Connector

1

14

02011021

O-Ring

   

for

 

Rotor

 

Connector

1

15

02011018

O-Ring

1

16

01013038

Base

 

for

 

1

.

5" 4

-

way

 

Valve

 (

Clamp

)

1

17

02011027

O-Ring

 

for

 

1

.

5" 4

-

way

 

Valve

 (

Thread

)

1

02011028

O-Ring

 

for

 

1

.

5" 4

-

way

 

Valve

 (

Clamp

)

1

18

89281301

1.5" 4-way

 

Valve

 

Body

1

19

02020013

O-Ring

 

for

 

1.5" Connector

3

20

01013015

1.5" Connector

 (

black

)

3

21

02011003

O-Ring

 

for

 

1

.

5" Union

3

22

01171153

1.5" Union

 (

A

/

E

)

2

23

01013017

1.5" Union

 

Nut

 (

black

)

3

FILTER & PUMP COMBO

Installation & Operating Instruction

* Install filtration system including pump,filter tank and multiport valve. 
* The filter system should be installed as close as possibie to the swimming pool and preferably at a level 

of 0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available 

at the place where the filter is to be installed. 

PUMP

1) Only qualified,licensed personnel should install pump and wiring.
2) Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply 

trough an approved and correctly rated contractor.

3 Allow for gate valve in suction piping. 

4 Pump suction and discharge connections have moulded in 

thread stops,do not try to screw pipe in

beyond these stops.

FILTER TANK and MULTIPORT VALVE

1 Loading the sand media.Filter sand media is loaded through the top opening of the filter.

 a Loosen the plastic clamps from tank neck.

 b Cap internal pipe with plastic cap to prevent sand from entering it.

 c We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter 

sand is poured in. This helps protect the under-drain laterals from excessive shock.

 d Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in 

 

opening.

Sand surface should be leveled and should come to about the middle of the filter tank.Remove 
plastic cap from internal pipe.

2 Assemble filter control valve to filter tank.

 a Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe 

slips into the hole in the bottom of the valve.

 b Place two plastic clamps around valve flange and tank neck and tighten just enough so that the  

valve may Be rotated on tank for final positioning.

 c Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-tighten.

 d Connect pump to control valve opening marked PUMP with hose.After connections are made,tighten 

clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.

3 Make return to pool pipe connection to control valve opening marked RETURN and complete other 

necessary plumbing connections,suction lines to pump,waste,etc.

4 To prevent water leakage,be sure all pipe connections are tight.

INSTALLATION

4

1

EMFS16030901 

Отзывы: