FSP350-4W / FSP400-4W / FSP450-4W / FSP500-4W / FSP650-4W
1.5" VALVE REPLACEMENT PARTS
Used after backwash to flush dirt from valve
Cleaning Filter by reversing the flow
CLOSED
Shuts off all flow to filter or pool
RINSE
BACKWASH
FILTER
Valve Position
Normal Filtration and Vacuuming
Function
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING
SYSTEM (e.g., CLAMP, PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE
SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO
BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE
TURN PUMP OFF BEFORE CHANGING VALVE POSITION.
WARNING
!
!
TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM,
CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY.
!
DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.
!
Key No
.
Part No.
Product
Description
Qty
1
03018009
Pin
for
handle
1
2
01013036
Handle
for
1.5" 4
-
way
Valve
1
3
03011003
Ø
4*12
Self
-
drilling
screw
5
4
01013040
Pressing
Ring
1
5
01013041
Fixation
for
1.5" 4
-
way
Valve
Handle
1
6
01181003
Washer
for
1.5" 4
-
way
Valve
Handle
1
7
02011017
O-Ring
for
Rotor
2
8
89280104
Sight
Glass
with
O-Ring
1
9
01111048
Connector
for
Pressure
Gauge
/
Stopper
1
10
06021013
Plastic pressure gauge With O-Ring(40Psi)
1
11
02311005
Spider
Gasket
1
12
01013098
Lid
for
for
1.5" 4-way
Valve
Rotor
1
01021003
Rotor
for
1.5" 4-way
Valve
1
13
01013039
1.5" 4-way
Valve
Rotor
Connector
1
14
02011021
O-Ring
for
Rotor
Connector
1
15
02011018
O-Ring
1
16
01013038
Base
for
1
.
5" 4
-
way
Valve
(
Clamp
)
1
17
02011027
O-Ring
for
1
.
5" 4
-
way
Valve
(
Thread
)
1
02011028
O-Ring
for
1
.
5" 4
-
way
Valve
(
Clamp
)
1
18
89281301
1.5" 4-way
Valve
Body
1
19
02020013
O-Ring
for
1.5" Connector
3
20
01013015
1.5" Connector
(
black
)
3
21
02011003
O-Ring
for
1
.
5" Union
3
22
01171153
1.5" Union
(
A
/
E
)
2
23
01013017
1.5" Union
Nut
(
black
)
3
FILTER & PUMP COMBO
Installation & Operating Instruction
* Install filtration system including pump,filter tank and multiport valve.
* The filter system should be installed as close as possibie to the swimming pool and preferably at a level
of 0.50 metres below the surface of the water in the swimming pool. Make sure there is drainage available
at the place where the filter is to be installed.
*
PUMP
1) Only qualified,licensed personnel should install pump and wiring.
2) Electrical Contractors Please Note:All 220 volt 50Hz pump must be wired to the main power supply
trough an approved and correctly rated contractor.
3 Allow for gate valve in suction piping.
)
4 Pump suction and discharge connections have moulded in
)
thread stops,do not try to screw pipe in
beyond these stops.
*
FILTER TANK and MULTIPORT VALVE
1 Loading the sand media.Filter sand media is loaded through the top opening of the filter.
)
a Loosen the plastic clamps from tank neck.
)
b Cap internal pipe with plastic cap to prevent sand from entering it.
)
c We recommend filling tank approximately 1/2 way with water to provide a cushion effect when the filter
)
sand is poured in. This helps protect the under-drain laterals from excessive shock.
d Carefully pour in correct amount and grade of filter sand.Be sure center pipe remains centered in
)
opening.
Sand surface should be leveled and should come to about the middle of the filter tank.Remove
plastic cap from internal pipe.
2 Assemble filter control valve to filter tank.
)
a Insert filter control valve(with O'ring in place)into the tank neck,taking care that the center pipe
)
slips into the hole in the bottom of the valve.
b Place two plastic clamps around valve flange and tank neck and tighten just enough so that the
)
valve may Be rotated on tank for final positioning.
c Carefully screw pressure gauge(with O'ring in place)into tapped hole in valve body.Do not over-tighten.
)
d Connect pump to control valve opening marked PUMP with hose.After connections are made,tighten
)
clamps with screwdrive,tapping around clamp with screwdrive handle to help seat valve flange clamp.
3 Make return to pool pipe connection to control valve opening marked RETURN and complete other
)
necessary plumbing connections,suction lines to pump,waste,etc.
4 To prevent water leakage,be sure all pipe connections are tight.
)
INSTALLATION
4
1
EMFS16030901