![EM2GO EMB011AC1RW Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/em2go/emb011ac1rw/emb011ac1rw_user-manual_2398538007.webp)
Type 2 Plug
3-Phase Type 2 Socket
Thank you for choosing the EM2GO charging station
for electric vehicles.
With this smart wallbox, you have chosen a high-precision EV charger equipped with many
safetyrelated protection devices, which guarantees all-round carefree charging of your vehicle.
Important Notice:
This manual contains important instructions and information to be observed during installation,
operation and maintenance. Read all safety information and warnings in this manual to be aware of
potential hazards.
This manual is intended for installation and maintenance personnel as well as end customers.
Keepthis user manual in a safe place.
Safety signs used
The following warning, command and information signs are used in this manual, on and in the
EV charging station.
CAUTION:
Warning of electrical hazards.
This sign is intended to alert the user that serious injury or substantial property damage
may result if the equipment is not operated as instructed.
WARNING:
Warning of a hazardous location or dangerous situation.
This sign is intended to alert the user that minor injury or property damage may result if the
equipment is not operated as instructed.
CAUTION:
Do not touch with hands when electrostatic discharge is possible. Indicates
the possible consequences of touching electrostatically sensitive components.
IMPORTANT NOTICE:
According to §19 NAV of March 21, 2019, the operation of charging devices for electric vehicles must
be reported to the responsible grid operator before use (from 11 KW), as well as before installation
(from 22 KW). This can also be done by the commissioned electrical installer.
Please contact your electricity provider by phone or online for more information.
WARNING!
When using electrical products, always observe these basic precautions.
• Do not install or use the charger near explosive, corrosive or flammable materials, chemicals or
vapors.
• The charger may only be installed on non-combustible surfaces such as concrete, and at least
120cm above the floor.
• The charger must be safely grounded.
• Turn off the power to the charger before assembling or servicing the charger.
• The device is designed only for vehicles compatible with the IEC 62196 standard for charging
modes.
• Do not use the charger if it is defective or has visible damage
• Do not attempt to öffnen, disassemble, repair, tamper with or modify the device. If you have
any questions or need repairs, contact our customer service department.
• Do not use the charger when you are in the vehicle.
• Do not use the charger when exposed to heavy rain, snow or inclement weather.
• Always exercise caution when transporting the charger.
• Do not touch the charging terminal with sharp metallic objects
• Do not pull the charging cable with force or over sharp objects.
WARNING!
The device may only be installed, adjusted and serviced by qualified persons familiar with the cons
-
truction and operation of this type of electrical equipment.
Failure to observe this precaution can result in serious injury or even death.
• Incorrect installation and testing of the charger can possibly lead to damage. No liability is accepted
for the resulting damage.
• Ensure that the charging cable is correctly positioned during the charging process and cannot
be stepped on, damaged or stressed.
• Check wire diameter according to local electrical requirements.
• Switch off the corresponding power supply before starting the installation.
• The charger must be installed and commissioned by qualified personnel.
• Before installation, the supply cable and house connection values must be checked.
Abbreviations:
A |
ampere, unit of current
V |
volt, unit of voltage
EV |
electric vehicle
EVSE |
Equipment for the supply of EV according to IEC61851-1
RFID |
Radio Frequency Identification Card
IP |
Protection class
RCMU |
Residual current monitoring unit
MCB |
Circuit breaker
Technical data:
• Operating voltage: 400V AC ±10%, 50-60 Hz, 3-phase
• Operating current: 16A
• Max. Output power Typically 11 kW
• Housing: IP65, splash-proof
• Input terminals: L1, L2, L3, N, PE
• Connection: Type 2 plug
• IEC 61851-1 Charging mode: Mode 3
• Communication interfaces: Communication interface: BT, RFID
• Safety devices: Overvoltage protection, overtemperature, over/undervoltage, overcurrent,
protection against fault currents (RCMU 30mA AC+6mA DC) and protective conductor faults
for TN system (TN-C, TN-S and TN-C-S).
• Display: LED
• Structure: CE standards IEC 61851-1 IEC 62196-2:2016, IEC 60364-7-722
• Material: PC+ASA
• Connection length: type 2 cable 5 meters, supply cable 60cm (5x4mm²)
• Operating temperature: -30 to +55 °C
• Dimensions: 180 mm × 180 mm × 64.5 mm
• Weight: 4kg
Representation of Type2 plug / socket according to
IEC 62196-2
GB
GB
11
12