General Information Concerning this User Manual

• 

Read this user manual carefully before starting the system! 

• 

This document is intended for the BioProTT

TM 

 Clamp-On SL and it describes the use of 

the BioProTT

TM

 Clamp-On SL.

• 

The user (= the person who connects the BioProTT

TM

 Clamp-On SL to the 

tubing circuit and measurement system) is responsible for any risk if the 

 

BioProTT

TM

 Clamp-On SL is not connected correctly.

• 

The customer must ensure that the persons involved in the integration and use of the 
BioProTT

TM

 Clamp-On SL and the systems it is part of are adequately qualified. In addition, 

the information in this user manual must be followed. 

Please note: 

As the BioProTT

TM

 Clamp-On SL is part of a system, the user manual of the evaluation 

device must also be taken into account and adhered to. 

This user manual contains important information concerning the safe and correct handling of the 

 

BioProTT

TM

 Clamp-On SL.  Keep it in an easily accessible location and familiarize yourself with all 

warning and safety information and observe them. It is the responsibility of the operator (= the 
person running and operating the system the BioProTT

TM

 Clamp-On SL is part of) to ensure that the  

BioProTT

TM

 Clamp-On SL is used, inspected and maintained in accordance with the user manual. This also applies 

for all subsequent revisions or instructions from the manufacturer. The manufacturer reserves the right to 
modify technical data without prior notice. 

Intended Purpose, Restrictions and Limitations

5.1 

Intended Purpose

The BioProTT

TM

 Clamp-On SL is indicated for the non-invasive and contactless bi-directional volumetric 

measurement of the liquid flowing through tubing systems (in combination with an evaluation device of the 

BioProTT

TM

 Product Range). The measurement principle is the ultrasonic transit time method. 

The BioProTT

TM

 Clamp-On SL can be used in applications such as:

 chromatographies

  adding media to bioreactors

  filtration

  fill and finish processes

  filling processes

  process evaluation

 upscaling

  feed control

 research

Additionally, the BioProTT

TM

 Clamp-On SL can be used in any processes where liquid flows through a flexible 

tubing system at flow rates that lie within the relevant sensor's specification. 

For more information regarding applications the BioProTT

TM

 Clamp-On SL can be used in, please contact  

em-tec GmbH

BioProTT™ Clamp-On SL

Copyright em-tec GmbH

Page  7

D162-704 BioProTT™ Clamp-On SL – User Manual– V4.0 

DocuSign Envelope ID: BE88571C-E493-4DFB-AF9A-864EB3FC3D75

Содержание BioProTT Clamp-On SL

Страница 1: ...BioProTTTM Clamp On SL User Manual DocuSign Envelope ID BE88571C E493 4DFB AF9A 864EB3FC3D75...

Страница 2: ...c GmbH Finning All rights reserved Subject to Technical Changes Owing to our policy of continuous product development the illustrations and technical data contained in this document may differ slightl...

Страница 3: ...Maintenance and Service 9 6 Use of the BioProTTTM Clamp On SL 10 6 1 General Safety Information 10 6 2 Connecting the BioProTTTM Clamp On SL to the Evaluation Device 10 6 3 Attaching the BioProTTTM Cl...

Страница 4: ...itoring and control of the upstream feed monitoring and control of the downstream feed filtration fill and finish processes process evaluation upscaling processes research The SL at the end of the pro...

Страница 5: ...Clamp On SLs incorporate two pairs of transducers i e four piezo ceramics in total which are arranged in an X configuration around the tube containing the measured flow When sending ultrasonic signals...

Страница 6: ...aning Do not dispose of this device together with domestic waste The device as a whole as well as any parts must be disposed of in accordance with WEEE Directive and national legislation Manufacturer...

Страница 7: ...Clamp On SL is part of to ensure that the BioProTTTM Clamp On SL is used inspected and maintained in accordance with the user manual This also applies for all subsequent revisions or instructions from...

Страница 8: ...8 Troubleshooting as well as to the user manual of the evaluation device respectively 5 5 Electrical Safety and Electromagnetic Compatibility The BioProTTTM FlowMeasurement System i e the BioProTTTM C...

Страница 9: ...service for the BioProTTTM Clamp On SL may be carried out by em tec GmbH only If these instructions are not followed em tec GmbH shall accept no liability for the component and the warranty will be vo...

Страница 10: ...TTM FlowTrack SL To connect the BioProTTTM Clamp On SL to the BioProTTTM FlowTrack SL follow the steps listed below Carefully attach the round sensor plug to the sensor connection of the evalution dev...

Страница 11: ...t deformed damaged or dirty Ensure that the tube size and the tube material used corresponds with the size of the BioProTTTM Clamp On SL Air in the tube can lead to errors in the measurement or interr...

Страница 12: ...ease refer to the user manual of the respective BioProTTTM evaluation device Make sure to follow the steps described below and to heed the warnings included in them in order to ensure the highest poss...

Страница 13: ...ued or no flow value is displayed as the low coupling might impair the measurement It is important that any unwanted interruption of the process due to damage or kinking of the tubing is avoided at al...

Страница 14: ...ction of the BioProTTTM Clamp On SL Make sure that no detergents or disinfectants leak into the sensor plug For the cleaning of the device we recommend commonly used detergents and or the recommended...

Страница 15: ...ensor or to fix it in one position em tec offers optional mounting solutions The features differ slightly in regard to their design and handling depending on the sensor size Sensors with an OD of up t...

Страница 16: ...or torsial moment caused by the tube are too high the thread may tear the sensor base body may break or the sensor might be levered out If the mounting feature and thus sensor is not positioned corre...

Страница 17: ...mmends regular calibrations to be carried out Ideally the time between re calibrations should not exceed 24 months Other than the adjustment the calibration can be carried out by the customer on site...

Страница 18: ...nfluence the sensor or if the sensor or its cable came into contact with an electric cautery 2 Check the grounding of the valves and pumps or any other devices that might create electromagnetic distur...

Страница 19: ...nsor lid is closed properly 2 Close the lid If the problem persists contact our service department The tube size and or material is not the one indicated for the sensor 1 Check if the tube size and ma...

Страница 20: ...hannel If the problem persists contact our service department There might be electromagnetic fields influencing the sensor 1 Check if the sensor is damaged or not connected properly to the device 2 Ch...

Страница 21: ...sories must be disposed of in accordance with the applicable national provisions for electronic components In accordance with the requirements of EU Directive 2012 65 EC Waste Electrical and Electroni...

Страница 22: ...to OD 7 8 2 of reading 80 ml min up to OD 1 1 8 2 of reading 200 ml min up to OD 1 5 8 2 of reading 400 ml min The specified accuracies were determined under the following conditions Medium Water Med...

Страница 23: ...9 16 13433 PCT 3 8 x 1 8 0 017 2 5 0 100 10 3 8 1 8 5 8 13422 PCT 1 2 x 3 32 0 017 2 5 0 100 16 9 2 40 1 2 3 32 11 16 13428 PCT 1 2 x 1 8 0 017 2 5 0 100 16 9 2 40 1 2 1 8 3 4 13430 PCT 1 2 x 3 16 0 0...

Страница 24: ...1 2 x 3 16 PCT 3 4 x 1 8 PCT 3 4 x 3 16 PCT 1 x 1 8 PCT 1 x 3 16 PCT 1 1 4 x 3 16 Size H x W x D 85 x 80 x 10 6 mm 100 x 80 x 10 6 mm Weight 28 g 31 g Material polyamide polyamide Mounting four M5 scr...

Страница 25: ...nue of approximately 7 billion We deliver innovative equipment and components consumable supplies aftermarket parts software and digital solutions and support services through five operating segments...

Отзывы: