4  Introduction 

4.1  Purpose 

This chapter provides a general description of CMi4110. In the next-coming sections you will learn more 
about possible applications for the product and how CMi4110 can be combined

 

with other products to 

build versatile solutions. 

4.2  Application description 

CMi4110 is a cost-effective LoRaWAN meter connectivity module, which is mounted in a Gyr 
UH50 meter or a UC50 calculator. It uses a very energy-efficient scheme to deliver meter data to a 
receiving (application) server over a LoRaWAN network. Meter data is securely transmitted, using 
LoRaWAN end-to-end security scheme.  
  
CMi4110 can both be retrofitted into deployed meters or mounted before deployment. 

 

4.3  Product features 

CMi4110 has the capability to offer a combination of battery operation with very long lifetime and a 
versatile application through its many configuration options. Key features of the module include: 

 

 

Long battery lifetime

 

The module’s EcoMode feature enables the module to achieve a battery-lifetime of at least 11+1 
years. 

 

No meter installation needed

  

As soon as the meter connectivity module has been mounted and started up, it will join the 
LoRaWAN network and start delivering meter data, i.e. no manual steps need to be taken in 
order to install the product in the meter. 

 

Quick commissioning

 

The product uses Elvaco’s One-Touch Commissioning (OTC) solution to securely and quickly 
configure products deployed. Us

ing Elvaco’s OTC App, simply enter your desired settings and 

place your phone on the right side of the L+G UH50 meter / UC50 calculator. New settings will be 
applied instantaneously via NFC. 

 

A unique and flexible message scheme

 

 

Meter data aligned with mete

r’s internal clock and redundant daily energy values enables 

coordinated high-precision readouts without network congestion and assures reliable 
delivery of daily energy consumption. 

 

Several message formats to choose between, including JSON, gives the right fit for the 
unique demands of each application.  

 
 

Содержание CMi4110

Страница 1: ...CMi4110 User s Manual English...

Страница 2: ...PRODUCT SPECIFICATION 8 5 3 MOUNT AND START UP THE DEVICE 8 5 3 1 Mounting and connection 8 5 3 2 Connection of antenna 8 5 3 3 Start up and LED indications 9 5 3 4 Switch off reboot module 10 6 ADMIN...

Страница 3: ...ion and product are provided on an as is basis only and may contain deficiencies or inadequacies Elvaco AB takes no responsibility for damages liabilities or other losses by using this product 1 1 Cop...

Страница 4: ...into all manuals supplied with the product Failure to comply with these precautions violates safety standards of design manufacture and intended use of the product Elvaco AB assumes no liability for c...

Страница 5: ...e Note symbol is used to mark information that is important to take into consideration for safety reasons or to assure correct operation of the meter connectivity module The Tip symbol is used to mark...

Страница 6: ...h its many configuration options Key features of the module include Long battery lifetime The module s EcoMode feature enables the module to achieve a battery lifetime of at least 11 1 years No meter...

Страница 7: ...l L G UH50 meters using software version 5 15 or higher as well as with all L G UC50 calculators using software version 8 06 or higher CMi4110 is supplied with power from the UH50 UC50 D cell battery...

Страница 8: ...Mounting and connection CMi4110 is mounted in module slot 2 of a L G UH50 heat meter or a L G UC50 heat calculator 5 3 2 Connection of antenna If using CMi4110Ext the SMA connector 6 is used to conne...

Страница 9: ...r 8 seconds as illustrated by Figure 1 If the module fails to join the LoRaWAN network 6 times it will wait for 60 minutes before another join attempt is initiated in order to conserve battery A new j...

Страница 10: ...4 Switch off reboot module To reboot the module press and hold the push button 2 for 5 15 seconds Release the button when the green LED is lit To switch off the module press and hold the push button...

Страница 11: ...app is only compatible with Android phones with Android 5 0 or later Table 2 provides a summary of all settings Field name Abbr Description Default value Device access Locked device correct Product A...

Страница 12: ...2 bit number Writeable N A N A Network session key Encryption key for payload data only applicable in ABP mode Device unique 128 bit number Writeable N A N A Current data rate The current data rate us...

Страница 13: ...l be transmitted each day regardless of the data rate Table 4 provides a set of examples MaxDTx value Maximum transmit interval 1 Once per day 24 Once per hour 48 Once per 30 minutes 96 Once per 15 mi...

Страница 14: ...1 byte 0 Standard 1 Compact 2 JSON 3 Scheduled daily redundant 4 Scheduled extended Table 5 Message type field 6 6 2 Structure and payload In this section a detailed description of each message format...

Страница 15: ...cimals 0C15xxxxxxxx m3 1 decimal 0C16xxxxxxxx m3 0 decimals 3 Power 5 bytes including DIF VIF BCD8 M Bus Type A Power kW Mapped to OBIS 6 4 0B2Bxxxxxx kW 3 decimals 0B2Cxxxxxx kW 2 decimals 0B2Dxxxxxx...

Страница 16: ...al 0CFB01xxxxxxxx MWh 0 decimals 0C06xxxxxxxx kWh 0C0Exxxxxxxx GJ 3 decimals 0C0Fxxxxxxxx GJ 2 decimals 0CFB08xxxxxxxx GJ 1 decimal 0CFB09xxxxxxxx GJ 0 decimals 2 Meter ID 6 bytes including DIF VIF Ac...

Страница 17: ...ed in Table 11 Table 9 Clock message and data message The clock message will be transmitted once every day and the data message at least regulated by MaxDTx parameter once every day on LoRa port 3 Fig...

Страница 18: ...umulated energy read at 24 00 will be transmitted 12 times during the 24 next coming hours Figure 9 DIB structure message type scheduled daily redundant DIB Field Size Data type Description 1 Energy 6...

Страница 19: ...imestamp is not valid 4 Accumulated energy at 24 00 6 Bytes including DIF VIF BCD8 M Bus Type A Energy consumption MWh kWh MJ GJ Mapped to OBIS 6 8 4C06xxxxxxxx MWh 3 decimals kWh 4C07xxxxxxxx MWh 2 d...

Страница 20: ...2 decimals 0C15xxxxxxxx m3 1 decimal 0C16xxxxxxxx m3 0 decimals 3 Power 5 bytes including DIF VIF BCD8 M Bus Type A Power kW Mapped to OBIS 6 4 0B2Bxxxxxx kW 3 decimals 0B2Cxxxxxx kW 2 decimals 0B2Dx...

Страница 21: ...6 M Bus Type C Error and warning flags 02FD17xxxx Meter communication error message When CMi4110 is unable to communicate with UH50 UC50 an error message will be transmitted on the LoRaWAN network Tab...

Страница 22: ...al only applies when EcoMode is inactive 0x06 0x02 0xNumber of minutes lsByte msByte Message format 0x07 0x01 0x00 Message format Standard 0x01 Message format Compact 0x02 Message format JSON 0x03 Mes...

Страница 23: ...DC24 00 Electrical characteristics Nominal voltage 3 0 5 0 VDC Power consumption max 40 mA Power consumption sleep mode 2 2 A Environmental specifications Operating temperature 5 55 C Operating humidi...

Страница 24: ...CMi4110 User s Manual English v1 3 CMi4110 User s Manual English v1 3 page 24 27 2018 06 V1 3 Configuration NFC via Elvaco OTC app or downlink data...

Страница 25: ...al English v1 3 CMi4110 User s Manual English v1 3 page 25 27 2018 06 V1 3 8 Type approvals CMi4110 is designed to comply with the directives and standards listed below Approval Description EMC EN 301...

Страница 26: ...Document history 9 1 Versions Version Date Description Author v1 0 2018 07 Initial version Anton Larsson v1 1 2018 10 Information about Scheduled extended added Anton Larsson v1 2 2019 03 Corrected D...

Страница 27: ...tion Description DIB Data Information Block DIF Data Information Field VIF Value Information Field MCM Meter Connectivity Module 10 2 Number representation Decimal numbers are represented as normal nu...

Отзывы: