background image

Electronic thermostat

ETH 

eco

Operation and display 

General function

This  electronic  thermostat  for  radiators  can  be  used  to  

control room temperature on the basis of time. The actu-

ator moves a valve, thereby allowing the amount of heat 

flowing  to  the  heating  appliance  to  be  controlled.  The 

controller is compatible with all standard heating appli-

ance valves. 

Installation can be achieved in 3 easy steps.

Step 1: Inserting (replacing) the batteries

Remove  the  battery  com-

• 

partment cover.

Insert 2 new Mignon bat-

• 

teries  (LR6/AA)  into  the 

battery compartment, en-

suring  they  are  the  right 

way round.

Reattach the battery com-

• 

partment  cover  and  click 

into place.

New alkaline batteries have a life of approximately three 

years. A battery symbol (

) will indicate when the bat-

teries need to be replaced. After removing the old batter-

ies, please wait appro-ximately 1 minute before inserting 

the new ones. This device does not support operation with 

rechargeable batteries.

Never recharge standard batteries. 

Doing so will present a risk of explosion.

Do not throw the batteries into a fire. 

Do not short-circuit batteries.

Used  batteries  should  not  be  disposed 

of with regular domestic waste. Instead, 

they should be taken to your local battery 

disposal point.

Step 2: Setting the date and time of day

The firmware version number will be displayed briefly once 

you have inserted/replaced the batteries and then you will be 

automatically prompted to set the date and time of day.

Use the setting wheel (B) to set  

• 

the year (A).
Confirm with OK (C).

• 

Use the setting wheel (B) to set 

• 

the month (A).
Confirm with OK (C).

• 

Use the setting wheel (B) to set 

• 

the day (A).
Confirm with OK (C).

• 

Use the setting wheel (B) to set  

• 

the hour (A).
Confirm with OK (C).

• 

Use the setting wheel (B) to set  

• 

the minute (A).
Confirm with OK (C).

• 

The motor will start moving back the control pin while the 

entries are still being made.

If “INS” is displayed with a rotating “

• 

∏” symbol, this 

indicates that the motor is still moving back. Once the 

device is ready for the actuator to be installed on the 

valve, just “INS” will appear on the display.

The weekly program and other settings can be cus-

• 

tomised prior to installation. To do this, press the menu 

button when “INS” is shown on the display. For further 

details, please see “4. Configuration menu”. 

Once programming is complete, “INS” will reappear on the 

• 

display and installation (Step 3) can commence.

Step 3: Installing the electronic thermostat

The  actuator  can  be  installed  on  all  standard  heating 

valves.  There  is  no  need  to  drain  away  water  or  fiddle 

around with the heating system before doing this. First, 

you need to remove the old thermostat dial:

Turn the thermostat dial anti- 

• 

clockwise as far as it will go (A).

Release the thermal ring of the 

• 

thermostat (B).

Remove  the  thermostat  from 

• 

the valve (C).

An adapter will need to be used 

in  the  case  of  certain  valves. 

Adapters for Danfoss valves (RA, RAV, RAVL) are inclu-

ded in the scope of delivery. For details, please refer to the 

adapter overview (see 18).

The adapter must be placed 

• 

on the valve and turned until 

it is securely seated.

In the case of the RAV adapter, 

• 

the extension supplied must be 

attached to the valve tappet.

The  RA  and  RAV  adapters 

• 

must, in addition, be secured 

by means of the bolt and nut 

supplied.

The electronic thermostat can only be installed if “INS” is 

showing on the display. Following installation, the actuator 

will perform an adjustment run so that it can adapt to the 

valve. During this process, “ADA” will be displayed.

Place the actuator on the valve.

• 

Tighten the union nut.

• 

“INS” will appear on the display, press the OK button.

• 

The actuator will perform an adjustment run (“ADA” will 

• 

appear on the display, operation not possible).

After that, the actuator will be ready for operation (Auto 

• 

mode).

If the adjustment run was initiated prior to installa-

tion, or if an error message will be displayed (F1, F2, 

F3); press OK to move the motor back to the “INS” 

position.

1. Setting the weekly program

The weekly program allows you to set up to 3 separate 

heating  periods  (7  switching  times)  for  each  day  of  the 

week.  Programming  is  performed  in  relation  to  the  se-

lected days, for which temperatures must be stored for a 

period from 00:00 to 23:59.

Press and hold down the menu button for more than 3 seconds. 

“PRO” will appear on the display.

• 

Confirm with OK.

• 

“DAY” will appear on the display. The setting wheel can 

• 

be used to select an individual day of the week, all wor-

king  days,  the  weekend  or  the  entire  week  (example 

shows working days selected).

Confirm with OK.

• 

The first setting time will appear on 

• 

the display (0:00). This cannot be 

changed.  In  addition,  the  display 

shows  bars  for  every  other  swit-

ching interval.

Confirm with OK.

• 

Set  the  temperature  that  is  to  be 

• 

maintained from 0:00 onwards (ex-

ample shows 17.0°C).

Confirm with OK.

• 

The next switching time appears on  

• 

the display (example shows 6:00). 

Use the setting wheel to set the time.

Confirm with OK.

• 

Then, select a temperature for the 

• 

selected switching time.

Keep repeating this process until you have finished storing 

• 

temperatures for the period from 0:00 to 23:59.

After all 7 switching times have been selected, 23:59 will 

• 

appear on the display as end time.

Confirm with OK.

• 

In Auto mode, the temperature can be modified at any time 

via the setting wheel. The modified temperature will then 

be retained until the next program changeover.

2. Weekly program: Examples

The  electronic  thermostat  allows  you  to  store  up  to  3  

heating periods (7 switching times) with individual temper-

ature settings for each day of the week. The factory set-

ting consists of two heating phases (from 6:00 until 9:00 

and from 17:00 until 23:00 respectively) for every single 

day of the week:

From  00:00  to  06:00  17.0°C

From  06:00  to  09:00  21.0°C

From  09:00  to  17:00  17.0°C

From  17:00  to  23:00  21.0°C

From  23:00  to  23:59  17.0°C

To represent the switching periods, the display shows 

bars for every other switching interval. In this exam-

ple, no bars are shown for the interval from 0:00 to 

6:00. Bars are only shown on the display for the in-

tervals from 6:00 to 9:00 and from 17:00 to 23:00. 

If a room also needs to be heated at around noon, the cor-

responding program might look like this:

Monday to Sunday

From  00:00  to  06:00  16.0°C

From  06:00  to  09:00  22.0°C

From  09:00  to  12:00  17.0°C

From  12:00  to  14:00  20.0°C

From  14:00  to  17:30  17.0°C

From  17:30  to  23:30  21.0°C

From  23:30  to  23:59  16.0°C

If you have a home office and only want it to be heated 

during the day on working days, you can program the fol-

lowing times:

Monday to Friday

From  00:00  to  08:30  17.0°C

From  08:30  to  17:00  21.0°C

From  17:00  to  23:59  17.0°C

Saturday and Sunday

From  00:00  to  23:59  15.0°C

3. Operating modes

To switch between the 3 operating modes described below, 

press the menu button briefly (these operating modes can 

only be selected following installation/Step 3):

Holiday function

• 

 (   )

Set a temperature that is to be 

maintained until a fixed point in time.

Manu: 

• 

Manual operation – The temperature is set manu-

ally using the setting wheel.

Auto: 

• 

Weekly program – The temperature is controlled auto-

matically in accordance with the stored weekly program.

Please read this manual carefully in order to help you put 

the device into operation. Keep the manual handy so you 

can refer to it at a later date!

A  Thermal ring

B  Holiday function (   ), set-back/comfort temperature 

 ), manual operation (

Manu), automatic operation 

(

Auto)

C  “Window open” symbol (   ), day of the week, “bat-

tery empty” symbol ( 

 )

D  Menu button: Press and hold down the button for more 

than 3 seconds to open the configuration menu

E  Setting wheel: For making adjustments (e.g. temperature)

F  Switching periods set within weekly program

G  Current temperature setting , time and date indicator, 

menu items, functions

 button: For switching between set-back and com-

fort temperatures

OK button: For confirming/saving

5

2

6

3

7

4

8

ELV Elektronik AG · P.O.Box 1000 · D-26787 Leer