75 channel mode DMX chart

CH1

R1

0-100%

CH25

R9

0-100%

CH13

R5

0-100%

CH37

R13

0-100%

CH49

R17

0-100%

CH61

R21

0-100%

CH73

R25

0-100%

CH2

G1

0-100%

CH26

G9

0-100%

CH14

G5

0-100%

CH38

G13

0-100%

CH50

G17

0-100%

CH62

G21

0-100%

CH74

G25

0-100%

CH3

B1

0-100%

CH27

B9

0-100%

CH15

B5

0-100%

CH39

B13

0-100%

CH51

B17

0-100%

CH63

B21

0-100%

CH75

B25

0-100%

CH4

R2

0-100%

CH28

R10

0-100%

CH16

R6

0-100%

CH40

R14

0-100%

CH52

R18

0-100%

CH64

R22

0-100%

CH5

G2

0-100%

CH29

G10

0-100%

CH17

G6

0-100%

CH41

G14

0-100%

CH53

G18

0-100%

CH65

G22

0-100%

CH6

B2

0-100%

CH30

B10

0-100%

CH18

B6

0-100%

CH42

B14

0-100%

CH54

B18

0-100%

CH66

B22

0-100%

CH7

R3

0-100%

CH31

R11

0-100%

CH19

R7

0-100%

CH43

R15

0-100%

CH55

R19

0-100%

CH67

R23

0-100%

CH8

G3

0-100%

CH32

G11

0-100%

CH20

G7

0-100%

CH44

G15

0-100%

CH56

G19

0-100%

CH68

G23

0-100%

CH9

B3

0-100%

CH33

B11

0-100%

CH21

B7

0-100%

CH45

B15

0-100%

CH57

B19

0-100%

CH69

B23

0-100%

CH10

R4

0-100%

CH34

R12

0-100%

CH22

R8

0-100%

CH46

R16

0-100%

CH58

R20

0-100%

CH70

R24

0-100%

CH11

G4

0-100%

CH35

G12

0-100%

CH23

G8

0-100%

CH47

G16

0-100%

CH59

G20

0-100%

CH71

G24

0-100%

CH12

B4

0-100%

CH36

B12

0-100%

CH24

B8

0-100%

CH48

B16

0-100%

CH60

B20

0-100%

CH72

B24

0-100%

Содержание Tri Pixel Panel 25 ELUM085

Страница 1: ...Tri Pixel Panel 25 Code ELUM085 USER MANUAL ...

Страница 2: ...1 ...

Страница 3: ...er cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation mig...

Страница 4: ...nted in free space with 300mm or greater of clearance behind the fixture to allow for sufficient airflow and cooling Technical Specifications 25 x 30W tri colour LEDs Beam angle 80 degrees 1100Hz refresh rate 0 100 dimming and variable strobe DMX channels 3 5 6 25C 25W 26 75 76 78 or 100 selectable Sound active auto master slave built in pro grammes and DMX modes 4 push button menu with LCD displa...

Страница 5: ...ct the desired mode and the slave units will now run in sequence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the SET UP button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the SET UP button to select the desired speed and adjust by using the UP and DOWN ...

Страница 6: ...r chase Speed flash adjustable Flow 3 Speed 00 99 Flash 00 99 7 colour chase Speed flash adjustable Flow 4 Speed 00 99 Flash 00 99 7 colour chase Speed flash adjustable Flow 5 Speed 00 99 Flash 00 99 7 colour chase Speed flash adjustable Flow 6 Speed 00 99 Flash 00 99 7 colour chase Speed flash adjustable Flow 7 Speed 00 99 Flash 00 99 7 colour chase Speed flash adjustable Flow 8 C1 RGB C2 RGB 7 c...

Страница 7: ...unction 1 0 255 Master dimmer 0 100 2 0 149 150 255 Static Pattern Moving Pattern slow to fast 3 0 149 Patern selector 4 0 99 Letters A Z 100 199 Numbrs 1 9 200 255 Patterns 5 0 255 Pattern colour selector 6 0 255 Background colour selector 6 ...

Страница 8: ... 0 255 Cell 8 0 100 9 0 255 Cell 9 0 100 10 0 255 Cell 10 0 100 11 0 255 Cell 11 0 100 12 0 255 Cell 12 0 100 13 0 255 Cell 13 0 100 14 0 255 Cell 14 0 100 15 0 255 Cell 15 0 100 16 0 255 Cell 16 0 100 17 0 255 Cell 17 0 100 18 0 255 Cell 18 0 100 19 0 255 Cell 19 0 100 20 0 255 Cell 20 0 100 21 0 255 Cell 21 0 100 22 0 255 Cell 22 0 100 23 0 255 Cell 23 0 100 24 0 255 Cell 24 0 100 25 0 255 Cell ...

Страница 9: ... 0 255 Cell 8 0 100 9 0 255 Cell 9 0 100 10 0 255 Cell 10 0 100 11 0 255 Cell 11 0 100 12 0 255 Cell 12 0 100 13 0 255 Cell 13 0 100 14 0 255 Cell 14 0 100 15 0 255 Cell 15 0 100 16 0 255 Cell 16 0 100 17 0 255 Cell 17 0 100 18 0 255 Cell 18 0 100 19 0 255 Cell 19 0 100 20 0 255 Cell 20 0 100 21 0 255 Cell 21 0 100 22 0 255 Cell 22 0 100 23 0 255 Cell 23 0 100 24 0 255 Cell 24 0 100 25 0 255 Cell ...

Страница 10: ...ell 12 0 100 13 0 255 Cell 13 0 100 14 0 255 Cell 14 0 100 15 0 255 Cell 15 0 100 16 0 255 Cell 16 0 100 17 0 255 Cell 17 0 100 18 0 255 Cell 18 0 100 19 0 255 Cell 19 0 100 20 0 255 Cell 20 0 100 21 0 255 Cell 21 0 100 22 0 255 Cell 22 0 100 23 0 255 Cell 23 0 100 24 0 255 Cell 24 0 100 25 0 255 Cell 25 0 100 26 0 25 Red 26 50 Blue 51 75 Green 76 100 Yellow 101 125 Pink 126 150 Purple 151 175 Coo...

Страница 11: ...00 CH41 G14 0 100 CH53 G18 0 100 CH65 G22 0 100 CH6 B2 0 100 CH30 B10 0 100 CH18 B6 0 100 CH42 B14 0 100 CH54 B18 0 100 CH66 B22 0 100 CH7 R3 0 100 CH31 R11 0 100 CH19 R7 0 100 CH43 R15 0 100 CH55 R19 0 100 CH67 R23 0 100 CH8 G3 0 100 CH32 G11 0 100 CH20 G7 0 100 CH44 G15 0 100 CH56 G19 0 100 CH68 G23 0 100 CH9 B3 0 100 CH33 B11 0 100 CH21 B7 0 100 CH45 B15 0 100 CH57 B19 0 100 CH69 B23 0 100 CH10...

Страница 12: ...0 CH17 G6 0 100 CH41 G14 0 100 CH53 G18 0 100 CH65 G22 0 100 CH6 B2 0 100 CH30 B10 0 100 CH18 B6 0 100 CH42 B14 0 100 CH54 B18 0 100 CH66 B22 0 100 CH7 R3 0 100 CH31 R11 0 100 CH19 R7 0 100 CH43 R15 0 100 CH55 R19 0 100 CH67 R23 0 100 CH8 G3 0 100 CH32 G11 0 100 CH20 G7 0 100 CH44 G15 0 100 CH56 G19 0 100 CH68 G23 0 100 CH9 B3 0 100 CH33 B11 0 100 CH21 B7 0 100 CH45 B15 0 100 CH57 B19 0 100 CH69 B...

Страница 13: ...8 55 GB 56 63 RB 64 71 RGB 72 79 Colour 1 80 87 Colour 2 88 95 Colour 3 96 103 Colour 4 104 111 Colour 5 112 119 Colour 6 120 127 Colour 7 128 135 Colour 8 136 143 Dream Speed 0 255 Slow to fast 144 151 Meteor 152 159 Fade 160 167 Change 168 175 Flow 1 176 183 Flow 2 184 191 Flow 3 192 199 Flow 4 200 207 Flow 5 208 215 Flow 6 216 223 Flow 7 224 231 Flow 8 232 239 Flow 9 240 255 Sound Sensitivity 0...

Страница 14: ...100 CH29 R8 0 100 CH17 R5 0 100 CH41 R11 0 100 CH6 G2 0 100 CH30 G8 0 100 CH18 G5 0 100 CH42 G11 0 100 CH7 B2 0 100 CH31 B8 0 100 CH19 B5 0 100 CH43 B11 0 100 CH8 Dimmer 2 0 100 CH32 Dimmer 8 0 100 CH20 Dimmer 5 0 100 CH44 Dimmer 11 0 100 CH9 R3 0 100 CH33 R9 0 100 CH21 R6 0 100 CH45 R12 0 100 CH10 G3 0 100 CH34 G9 0 100 CH22 G6 0 100 CH46 G12 0 100 CH11 B3 0 100 CH35 B9 0 100 CH23 B6 0 100 CH47 B...

Страница 15: ...100 Dimmer 25 0 100 CH53 R14 0 100 CH65 R17 0 100 CH77 R20 0 100 CH89 R23 0 100 CH54 G14 0 100 CH66 G17 0 100 CH78 G20 0 100 CH90 G23 0 100 CH55 B14 0 100 CH67 B17 0 100 CH79 B20 0 100 CH91 B23 0 100 CH56 Dimmer 14 0 100 CH68 Dimmer 17 0 100 CH80 Dimmer 20 0 100 CH92 Dimmer 23 0 100 CH57 R15 0 100 CH69 R18 0 100 CH81 R21 0 100 CH93 R24 0 100 CH58 G15 0 100 CH70 G18 0 100 CH82 G21 0 100 CH94 G24 0 ...

Страница 16: ...d 12 times the weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and should not be used Don t cover any ventilation openings as this may result in overheating Rigging with supplied hangi...

Страница 17: ...bracket on top of the unit making sure that both carry handles are folded flat Line up the bracket with the steel locating pins Now using a size 8 allen key turn the coffin lock and turn anti clockwise until you hear it lock into position Make sure that you hear a click and cannot turn the lock any more Fix 2 suitable safety cable s to the safety eyes to make sure the unit cannot drop more than 20...

Страница 18: ...e be sure that each unit is fixed together properly using the coffin locks on the left side and bottom side of the unit following the same method for the flying bracket When the units are lined up against each other use a size 8 allen key to turn the coffin lock turn the coffin lock anti clockwise until you hear it lock into position Make sure that you hear a click and cannot turn the lock any mor...

Страница 19: ... Unit name Tri Pixel Panel 25 Manufacturer Elumen8 Category LED Dimmer Firmware XXXX version of the software of the unit DMX address XXX current DMX start address of the unit DMX footprint XX current number of DMX channels used by the unit Personality XX current working DMX mode personality of the unit The DMX controller can send certain commands to each to each RDM unit which allows remote setup ...

Страница 20: ...smission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to sen...

Страница 21: ...emented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Using a cable terminator CABL90 3 pin or CABL89 5 pin will decrease the possibil...

Страница 22: ...etailer to purchase these accessories To keep up to date on the latest accessories and product range additions please visit www prolight co uk Optional Case Holds 6 x fixtures Order code ELUM085B Flying Brackets Order code ELUM085A ...

Страница 23: ...22 Notes ...

Страница 24: ......

Отзывы: