Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 511. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100,101,102,103,104,105 
and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in the 
chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output,  
see image below.

Note: DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be 

purchased from all good sound 

and lighting suppliers or  

Pro Light Concepts dealers.
Please quote:

CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

Содержание Endura UV100 COB

Страница 1: ...Order code ELUM461 Endura UV100 COB Exterior Fixture User Manual ...

Страница 2: ...nt and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power...

Страница 3: ... supply 100 240V 50 60Hz Fuse T2A 250V IP rating IP65 Dimensions 310 x 280 x 245mm Weight 5 2kg Order codes ELUM461 280mm 310mm 275mm 245mm The Endura series are heavy duty rental ready IP rated pars made for the most demanding of applications With flicker free operation thanks to a 3 600Hz refresh rate and a multitude of colour and output options the series is perfectly suited for use in concert ...

Страница 4: ...tted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture please ensure the seal is correctly positioned and free from damage to ensu...

Страница 5: ...ng Mode NO DMX Hold Blackout DMX Fail Setting Temp C F Fixture Temperature AutoLock OFF ON Auto Lock Menu Setting Op Time Fixture Run Time DFSE OFF ON Default Factory Settings Channel Value Function 1 000 255 Master dimmer 0 100 1 channel mode 8 bit Channel Value Function 1 000 255 Master dimmer 0 100 2 000 255 Dimmer fine 3 000 255 Strobe slow fast 3 channel mode 16 bit IMPORTANT PLEASE NOTE The ...

Страница 6: ... DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX address...

Страница 7: ... 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always ad...

Страница 8: ...ssible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally...

Отзывы: