background image

www.prolight.co.uk

Endura 1Q120 RGBW COB

  

User Manual

6

Operating instructions

Channel Value

Function

1

000-255 Red dimmer (0-100%)

2

000-255 Green dimmer (0-100%)

3

000-255 Blue dimmer (0-100%)

4

000-255 White dimmer (0-100%)

5

000-255 Strobe (slow-fast)

6

000-255 Master dimmer (0-100%)

7

000-004 No function
005-125 Colour change (slow-fast)
126-255 Colour fade (slow-fast)

8

000-045 Linear

Halogen

Dimming 

Curves

046-075 Square
076-105

Inverse Square

106-135 S-Curve
136-165 Linear

LED

Dimming 

Curves

166-195 Square
196-225 Inverse Square
226-255 S-Curve

8 channel mode (8 bit):

Channel Value

Function

1

000-255 Red dimmer (0-100%)

2

000-255 Green dimmer (0-100%)

3

000-255 Blue dimmer (0-100%)

4

000-255 White dimmer (0-100%)

5

000-255 Strobe (slow-fast)

6

000-255 Master dimmer (0-100%)

7

000-255 Dimmer fine

8

000-004 No function
005-125 Colour change (slow-fast)
126-255 Colour fade (slow-fast)

9

000-045 Linear

Halogen

Dimming 

Curves

046-075 Square
076-105

Inverse Square

106-135 S-Curve
136-165 Linear

LED

Dimming 

Curves

166-195 Square
196-225 Inverse Square
226-255 S-Curve

9 channel mode (16 bit):

Channel Value

Function

1

000-127 Colour macros
128-191 Colour change (slow-fast)
192-255 Colour fade (slow-fast)

1 channel mode (8 bit):

Channel Value

Function

1

000-255 Red dimmer (0-100%)

2

000-255 Green dimmer (0-100%)

3

000-255 Blue dimmer (0-100%)

4

000-255 White dimmer (0-100%)

4 channel mode (8 bit):

Содержание Endura 1Q120

Страница 1: ...Order code ELUM454 Endura 1Q120 RGBW COB Exterior Fixture User Manual ...

Страница 2: ...pment and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the po...

Страница 3: ... 310 x 280 x 245mm Weight 5kg Order codes ELUM453 280mm 310mm 275mm 245mm 0m 1m 2m 3m 4m 5m 16 Lux FULL ON R G B W 28400 5640 10300 1460 12100 7110 1410 2570 364 3030 3160 627 1140 162 1350 16 1780 353 643 91 758 1140 226 411 58 2 485 The Endura series are heavy duty rental ready IP rated pars made for the most demanding of applications With flicker free operation thanks to a 3 600Hz refresh rate ...

Страница 4: ...is fitted with an internal mains line fuse The fuse must only be changed by qualified personnel Before opening the fixtures housing or changing the fuse the fixture must be disconnected and isolated from the mains supply Replacement cartridge fuses must be of the same type and rating 20mm Glass T2A 250V When closing the fixture please ensure the seal is correctly positioned and free from damage to...

Страница 5: ...n RB Magenta RGBW Full on BLAC Blackout F000 F255 Static Colour Mode 02 FADE SP00 SP99 F000 F255 Colour Fade Mode 03 CHANG SP00 SP99 F000 F255 Colour Change Mode Manual R G B W STR Dim 000 255 Manual Dimming Mode Macros 00 63 Colour Macros NO DMX Hold Blackout DMX Fail Setting Temp C F Fixture Temperature WhiteBal R G B W 000 255 White Balance Setting AutoLock OFF ON Auto Lock Menu Setting Op Time...

Страница 6: ...unction 1 000 255 Red dimmer 0 100 2 000 255 Green dimmer 0 100 3 000 255 Blue dimmer 0 100 4 000 255 White dimmer 0 100 5 000 255 Strobe slow fast 6 000 255 Master dimmer 0 100 7 000 255 Dimmer fine 8 000 004 No function 005 125 Colour change slow fast 126 255 Colour fade slow fast 9 000 045 Linear Halogen Dimming Curves 046 075 Square 076 105 Inverse Square 106 135 S Curve 136 165 Linear LED Dim...

Страница 7: ...ng DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addre...

Страница 8: ...L89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interference It is always...

Страница 9: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmental...

Страница 10: ...www prolight co uk Endura 1Q120 RGBW COB User Manual 10 ...

Страница 11: ...www prolight co uk Endura 1Q120 RGBW COB User Manual 11 ...

Страница 12: ...www prolight co uk Endura 1Q120 RGBW COB User Manual 12 ...

Отзывы: