BA-en-4003-2005_TUE30
7
1.1 Components
Terrabox TCB030
for installation in explosion hazard areas;
operating voltage 24 V DC or 115/230 V AC depending on design;
for connecting a clamp (two clamps for BIG-BAG grounding).
Terracompact II TCO030
for mounting on a standard rail NS35 in dry control rooms;
operating voltage 24 V DC;
for connecting a clamp (two clamps for BIG-BAG grounding).
Power supply TCON01
100…240 V AC, for supplying a maximum of 2 Terracompact II TCO030.
601KR/AW, 601KR/DW, 601KR/KW cable rewinder,
Series 70 ground clamps
see separate Operating Instructions BA-en-4007
Ground clamps TERRA
CLAMP
see separate Operating Instructions BA-en-4014
1.2 Variants
Terrabox TCB030:
Standard (1 ground contactor)
• TCB030/S0
24 V DC
TCB030/S1
115 V AC
TCB030/S2
230 V AC
Operating points:
ON <20 kOhm, OFF >50 kOhm / ±20 %
BIG-BAG (1 ground contactor):
• TCB030/B0
24 V DC
TCB030/B1
115 V AC
TCB030/B2
230 V AC
Operting points:
ON <50 MOhm, OFF >100 MOhm / ±20 %
BIG-BAG (2 ground contactor):
• TCB030/20
24 V DC
TCB030/21
115 V AC
TCB030/22
230 V AC
Operating points: ON <50 MOhm, OFF >100 MOhm / ±20 %
Terracompact II TCO030:
Standard: TCO030S
BIG-BAG: TCO030B
Power Supply TCON01 for Terracompact II TCO030