_________________________________________________________________________________
_________________________________________________________________________________
24 TAU-72.IP/TAU-36.IP Universal Network Terminal
5
DEVICE CONFIGURATION
You can connect to the device using the following methods: via web interface, via telnet/ssh protocols, or
using RS-232 cable.
The device runs on Linux, settings are stored as text files in a directory / etc ~ / config (in normal mode /
etc ~ is a link to the directory / etc, when booting from pressing F in directory / etc ~ is configured configured by
the user, and in the / etc directory factory configuration of the device).
Configuration files can be edited, are connected via the RS-232 or telnet via built-in text editor joe.
To save the contents of the directory / etc ~ non-volatile memory device, you must execute the save. The
changes take effect after rebooting the device.
5.1
TAU-72.IP/TAU-36.IP configuration via WEB Interface. Administrator Access
1
To configure the device, establish connection in the
web browser
, e.g. Firefox, Internet Explorer, etc. Enter
device IP address into address bar of web browser.
TAU-72.IP/TAU-36.IP factory default IP address
—
192.168.1.2, network mask
—
255.255.255.0
After entering IP address the device will request username and password.
Initial startup username: admin, password: rootpasswd.
The following menu will appear on the administrator's terminal: To prevent unauthorized access to device
in the future, it's recommended to change password (see Section
1
The description is an example of the configurator for TAU-72.IP device. For TAU-36.IP device settings are the same, the
number of configurable ports - 36
For security reasons, duration of authorized access session is limited for 20 minutes, i.e. if you are
inactive after establishing connection to the device interface for the stated amount of time, the
gateway will be forced to end the session. This restriction is not effective in cases when you leave
'Monitoring' or 'System info' pages open, as these pages perform periodic polling of the device
data.
Up to 4 users may connect to the device web interface simultaneously.