BA-en-2087-2207_Static Combi Cleaner SCC_P
15
3.7 Routing the high voltage cable
The high voltage cable must be routed to make sure that it does not make
contact with moving machine parts. Avoid mechanical deformations and
bending radii smaller than 60 mm. The high voltabe cable must not be
installed on the floor, as it may break under load; the cable must also not be
subjected to tensile stress.
3.8 Connecting the compressed air
The R36 ion blower nozzle is supplied with a plug-in connection for pneu-
matic hoses with an outer diameter of 8 mm. The plug-in connection can
be replaced by other hose connections with a G 1/4" or R 1/4" screw
thread.
3.9 Routing the air hose
The air hose must be routed to make sure that it does not make contact
with moving machine parts. Avoid mechanical deformation and exces-
sively small bending radii (see manufacturer´s specifications).
3.10 Compressed air properties
The compressed air must be free from oil, water and dust. If the air supply
hoses are very long, a water separator must be fitted immediately
upstream from the ion blower nozzle, the ion blower pistol or the ion
blower nozzle bar. Maximum rated air pressure depends on the used
nozzle type (see chap. 7 Technical specifications).
3.11 Impact of heat radiation
To ensure that the permissible operating temperature is not exceeded, the
blower nozzle must not be exposed to direct heat radiation.
Please also observe the operating instructions for the ion blower nozzles
R36, BA-en-2043 for all connections.
Содержание SCC-P
Страница 1: ...Operating Instructions Static Combi Cleaner SCC P BA en 2087 2207 Z 118074y_1 ...
Страница 2: ...2 BA en 2087 2207_Static Combi Cleaner SCC P ...
Страница 4: ...4 BA en 2087 2207_Static Combi Cleaner SCC P ...
Страница 21: ...BA en 2087 2207_Static Combi Cleaner SCC_P 21 8 Dimensions Fig 6 Dimensions Z 11805y_3 ...
Страница 22: ...22 BA en 2087 2207_Static Combi Cleaner SCC P ...
Страница 23: ......