_____________________________________________________________________________
____________________________________________________________________________
120
LTP-8X optical line terminal
command, if necessary.
LTP-8X(ont-template)("HSI-100-CaTV")# undefine rf-port-state
....
Step 4.
Apply the changes made
LTP-8X(ont-template)("HSI-100-CaTV")# do commit
27.2
ONT Configuration Templates Assignment
Step 1.
Switch to the ONT view. For group operations, you can use the range of ONT IDs, if necessary.
LTP-8X(config)# interface ont 0/0-10
LTP-8X(config)(if-ont-0/0-10)#
Step 2.
Assign configuration template to ONT by using the template command.
LTP-8X(config)(if-ont-0/0-10)# template HSI-100-CaTV
Step 3.
Define individual ONT parameters not specified in the template, if necessary.
LTP-8X(config)(if-ont-0/0-10)# rf-port-state enabled
Step 4.
Apply the changes made
LTP-8X(config)(if-ont-0/0-10)# do commit
27.3
ONT Configuration Preview with Templates
ONT configuration viewing is performed by using the
show interface ont <id> configuration
command.
[T] markers (Template) allow to discriminate template configuration parameters from the general ones.
In this example, Rf port state is the only general parameter
LTP-8X(config)(if-ont-0/0-10)# do show interface ont 0/0 configuration
-----------------------------------
[ONT0/0] configuration
-----------------------------------
Description:
''
Enabled:
true
Serial:
ELTX5C00008C
Password:
''
[T] Fec up:
false
[T] Downstream broadcast:
true
[T] Ber interval:
100000
[T] Ber update period:
60
Rf port state:
enabled
[T] Omci error tolerant:
false
Service [0]:
[T] Profile cross connect:
Service1
ONT Profile Cross Connect 1
[T] Profile dba:
AllServices ONT Profile DBA 1
Service [1]:
[T] Profile cross connect:
Service2
ONT Profile Cross Connect 2
[T] Profile dba:
AllServices ONT Profile DBA 1
Service [2]:
[T] Profile cross connect:
unassigned
[T] Profile dba:
unassigned
Service [3]: